Cargando…

Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. Reporte de casos

Advanced heart failure is a major health problem for which heart transplantation or left ventricular assist devices are the only effective treatments. Intra-aortic balloon pump inserted using femoral artery access as a bridge to heart transplantation is still frequently used, but has the disadvantag...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramirez-Ramos, Cristhian Felipe, Aranzazu-Uribe, Mateo, Pamplona, Alejandra, Gallego-Muñoz, Catalina, Uribe-Molano, Juan David, Muñoz Sierra, Juan Gonzalo, Vanegas-Cardona, Diego Mauricio, Tenorio-Mejia, Carlos Alberto, Eusse-Gomez, Carlos Alberto, Uribe-Londoño, Carlos Esteban
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Instituto Nacional Cardiovascular - INCOR 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10506553/
https://www.ncbi.nlm.nih.gov/pubmed/37727800
http://dx.doi.org/10.47487/apcyccv.v2i2.134
_version_ 1785107136061112320
author Ramirez-Ramos, Cristhian Felipe
Aranzazu-Uribe, Mateo
Pamplona, Alejandra
Gallego-Muñoz, Catalina
Uribe-Molano, Juan David
Muñoz Sierra, Juan Gonzalo
Vanegas-Cardona, Diego Mauricio
Tenorio-Mejia, Carlos Alberto
Eusse-Gomez, Carlos Alberto
Uribe-Londoño, Carlos Esteban
author_facet Ramirez-Ramos, Cristhian Felipe
Aranzazu-Uribe, Mateo
Pamplona, Alejandra
Gallego-Muñoz, Catalina
Uribe-Molano, Juan David
Muñoz Sierra, Juan Gonzalo
Vanegas-Cardona, Diego Mauricio
Tenorio-Mejia, Carlos Alberto
Eusse-Gomez, Carlos Alberto
Uribe-Londoño, Carlos Esteban
author_sort Ramirez-Ramos, Cristhian Felipe
collection PubMed
description Advanced heart failure is a major health problem for which heart transplantation or left ventricular assist devices are the only effective treatments. Intra-aortic balloon pump inserted using femoral artery access as a bridge to heart transplantation is still frequently used, but has the disadvantage of limiting the patient’s movements, hence exposing him or her to the hazards of immobility and threatening the success of the procedure or hindering recovery. Access through the subclavian artery has become an attractive alternative since it doesn’t impair the patient’s mobility, and there is increasing evidence supporting its use. We present the first case of subclavian counterpulsation balloon implantation in a cardiovascular care center in Colombia.
format Online
Article
Text
id pubmed-10506553
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Instituto Nacional Cardiovascular - INCOR
record_format MEDLINE/PubMed
spelling pubmed-105065532023-09-19 Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. Reporte de casos Ramirez-Ramos, Cristhian Felipe Aranzazu-Uribe, Mateo Pamplona, Alejandra Gallego-Muñoz, Catalina Uribe-Molano, Juan David Muñoz Sierra, Juan Gonzalo Vanegas-Cardona, Diego Mauricio Tenorio-Mejia, Carlos Alberto Eusse-Gomez, Carlos Alberto Uribe-Londoño, Carlos Esteban Arch Peru Cardiol Cir Cardiovasc Reporte De Caso Advanced heart failure is a major health problem for which heart transplantation or left ventricular assist devices are the only effective treatments. Intra-aortic balloon pump inserted using femoral artery access as a bridge to heart transplantation is still frequently used, but has the disadvantage of limiting the patient’s movements, hence exposing him or her to the hazards of immobility and threatening the success of the procedure or hindering recovery. Access through the subclavian artery has become an attractive alternative since it doesn’t impair the patient’s mobility, and there is increasing evidence supporting its use. We present the first case of subclavian counterpulsation balloon implantation in a cardiovascular care center in Colombia. Instituto Nacional Cardiovascular - INCOR 2021-06-30 /pmc/articles/PMC10506553/ /pubmed/37727800 http://dx.doi.org/10.47487/apcyccv.v2i2.134 Text en https://creativecommons.org/licenses/by-nc/4.0/Este es un artículo publicado en acceso abierto bajo una licencia Creative Commons
spellingShingle Reporte De Caso
Ramirez-Ramos, Cristhian Felipe
Aranzazu-Uribe, Mateo
Pamplona, Alejandra
Gallego-Muñoz, Catalina
Uribe-Molano, Juan David
Muñoz Sierra, Juan Gonzalo
Vanegas-Cardona, Diego Mauricio
Tenorio-Mejia, Carlos Alberto
Eusse-Gomez, Carlos Alberto
Uribe-Londoño, Carlos Esteban
Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. Reporte de casos
title Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. Reporte de casos
title_full Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. Reporte de casos
title_fullStr Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. Reporte de casos
title_full_unstemmed Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. Reporte de casos
title_short Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. Reporte de casos
title_sort balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardíaco. reporte de casos
topic Reporte De Caso
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10506553/
https://www.ncbi.nlm.nih.gov/pubmed/37727800
http://dx.doi.org/10.47487/apcyccv.v2i2.134
work_keys_str_mv AT ramirezramoscristhianfelipe balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT aranzazuuribemateo balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT pamplonaalejandra balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT gallegomunozcatalina balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT uribemolanojuandavid balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT munozsierrajuangonzalo balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT vanegascardonadiegomauricio balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT tenoriomejiacarlosalberto balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT eussegomezcarlosalberto balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos
AT uribelondonocarlosesteban balondecontrapulsacionintraaorticoporaccesosubclaviocomopuenteatrasplantecardiacoreportedecasos