Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5
The paper presents the results of an experimental study of a cylindrical orifice with the orifice diameter ratio β = 0.5 and the flow opening length-to-diameter ratio L/d = 1, with hydraulic oil flowing in the DN50 measuring channel. The measurements of the values characterising the oil flow were ma...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10507028/ https://www.ncbi.nlm.nih.gov/pubmed/37723199 http://dx.doi.org/10.1038/s41598-023-42451-0 |
_version_ | 1785107221661614080 |
---|---|
author | Golijanek-Jędrzejczyk, Anna Mrowiec, Andrzej |
author_facet | Golijanek-Jędrzejczyk, Anna Mrowiec, Andrzej |
author_sort | Golijanek-Jędrzejczyk, Anna |
collection | PubMed |
description | The paper presents the results of an experimental study of a cylindrical orifice with the orifice diameter ratio β = 0.5 and the flow opening length-to-diameter ratio L/d = 1, with hydraulic oil flowing in the DN50 measuring channel. The measurements of the values characterising the oil flow were made in the laminar flow regime, for the Reynolds numbers ranging between Re = 100 to 950. Based on the experimental tests, standard flow characteristics were created for four kinematic viscosity values in the range of 13.4–33.3 cSt, for which the average value of the discharge coefficient C in the tested flow rate range of q(v) < 0.5 dm(3)/s was determined. |
format | Online Article Text |
id | pubmed-10507028 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-105070282023-09-20 Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5 Golijanek-Jędrzejczyk, Anna Mrowiec, Andrzej Sci Rep Article The paper presents the results of an experimental study of a cylindrical orifice with the orifice diameter ratio β = 0.5 and the flow opening length-to-diameter ratio L/d = 1, with hydraulic oil flowing in the DN50 measuring channel. The measurements of the values characterising the oil flow were made in the laminar flow regime, for the Reynolds numbers ranging between Re = 100 to 950. Based on the experimental tests, standard flow characteristics were created for four kinematic viscosity values in the range of 13.4–33.3 cSt, for which the average value of the discharge coefficient C in the tested flow rate range of q(v) < 0.5 dm(3)/s was determined. Nature Publishing Group UK 2023-09-18 /pmc/articles/PMC10507028/ /pubmed/37723199 http://dx.doi.org/10.1038/s41598-023-42451-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Golijanek-Jędrzejczyk, Anna Mrowiec, Andrzej Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5 |
title | Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5 |
title_full | Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5 |
title_fullStr | Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5 |
title_full_unstemmed | Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5 |
title_short | Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5 |
title_sort | cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5 |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10507028/ https://www.ncbi.nlm.nih.gov/pubmed/37723199 http://dx.doi.org/10.1038/s41598-023-42451-0 |
work_keys_str_mv | AT golijanekjedrzejczykanna cylindricalorificetestinginlaminarflowwiththeorificediameterratiob05 AT mrowiecandrzej cylindricalorificetestinginlaminarflowwiththeorificediameterratiob05 |