Cargando…
Follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer
OBJECTIVES: the present study aims to evaluate cancer patients related to the catheter flow and the general satisfaction of these patients. METHODS: we studied 233 individuals diagnosed with cancer who underwent chemotherapy treatment through venous access through portocath between January 2015 and...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Colégio Brasileiro de Cirurgiões
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10508678/ https://www.ncbi.nlm.nih.gov/pubmed/37436280 http://dx.doi.org/10.1590/0100-6991e-20233367-en |
_version_ | 1785107590677528576 |
---|---|
author | CÉSAR, RODRIGO MELO LAGE, ANA P. DRUMMOND WAINSTEIN, ALBERTO |
author_facet | CÉSAR, RODRIGO MELO LAGE, ANA P. DRUMMOND WAINSTEIN, ALBERTO |
author_sort | CÉSAR, RODRIGO MELO |
collection | PubMed |
description | OBJECTIVES: the present study aims to evaluate cancer patients related to the catheter flow and the general satisfaction of these patients. METHODS: we studied 233 individuals diagnosed with cancer who underwent chemotherapy treatment through venous access through portocath between January 2015 and December 2019. RESULTS: 97% of the patients consulted had palliative chemotherapy, and 99.1% of patients reported satisfaction with the implantation process and treatment method. Regarding catheter flow according to venous return and drip during drug infusion, 98.7% of individuals presented good flow. CONCLUSIONS: the results show that catheter flow was satisfactory in all implant sites observed and emphasize the advantages of using a totally implanted catheter. This benefice happens due to the reduction of emotional factors that cause stress in cancer patients receiving chemotherapy, as well as the reduction of trauma and discomfort experienced by patients during the infusion of peripheral chemotherapy. |
format | Online Article Text |
id | pubmed-10508678 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Colégio Brasileiro de Cirurgiões |
record_format | MEDLINE/PubMed |
spelling | pubmed-105086782023-09-21 Follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer CÉSAR, RODRIGO MELO LAGE, ANA P. DRUMMOND WAINSTEIN, ALBERTO Rev Col Bras Cir Original Article OBJECTIVES: the present study aims to evaluate cancer patients related to the catheter flow and the general satisfaction of these patients. METHODS: we studied 233 individuals diagnosed with cancer who underwent chemotherapy treatment through venous access through portocath between January 2015 and December 2019. RESULTS: 97% of the patients consulted had palliative chemotherapy, and 99.1% of patients reported satisfaction with the implantation process and treatment method. Regarding catheter flow according to venous return and drip during drug infusion, 98.7% of individuals presented good flow. CONCLUSIONS: the results show that catheter flow was satisfactory in all implant sites observed and emphasize the advantages of using a totally implanted catheter. This benefice happens due to the reduction of emotional factors that cause stress in cancer patients receiving chemotherapy, as well as the reduction of trauma and discomfort experienced by patients during the infusion of peripheral chemotherapy. Colégio Brasileiro de Cirurgiões 2023-06-22 /pmc/articles/PMC10508678/ /pubmed/37436280 http://dx.doi.org/10.1590/0100-6991e-20233367-en Text en © 2023 Revista do Colégio Brasileiro de Cirurgiões https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License |
spellingShingle | Original Article CÉSAR, RODRIGO MELO LAGE, ANA P. DRUMMOND WAINSTEIN, ALBERTO Follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer |
title | Follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer |
title_full | Follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer |
title_fullStr | Follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer |
title_full_unstemmed | Follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer |
title_short | Follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer |
title_sort | follow up of utility and value of totally implantable chemotherapy catheter in 233 brazilian patients receiving chemotherapy to treat cancer |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10508678/ https://www.ncbi.nlm.nih.gov/pubmed/37436280 http://dx.doi.org/10.1590/0100-6991e-20233367-en |
work_keys_str_mv | AT cesarrodrigomelo followupofutilityandvalueoftotallyimplantablechemotherapycatheterin233brazilianpatientsreceivingchemotherapytotreatcancer AT lageanapdrummond followupofutilityandvalueoftotallyimplantablechemotherapycatheterin233brazilianpatientsreceivingchemotherapytotreatcancer AT wainsteinalberto followupofutilityandvalueoftotallyimplantablechemotherapycatheterin233brazilianpatientsreceivingchemotherapytotreatcancer |