Cargando…

Efficient Uncertainty Quantification in a Multiscale Model of Pulmonary Arterial and Venous Hemodynamics

Computational hemodynamics models are becoming increasingly useful in the management and prognosis of complex, multiscale pathologies, including those attributed to the development of pulmonary vascular disease. However, diseases like pulmonary hypertension are heterogeneous, and affect both the pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Colebank, M. J., Chesler, N.C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cornell University 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10508834/
https://www.ncbi.nlm.nih.gov/pubmed/37731656
_version_ 1785107617429848064
author Colebank, M. J.
Chesler, N.C.
author_facet Colebank, M. J.
Chesler, N.C.
author_sort Colebank, M. J.
collection PubMed
description Computational hemodynamics models are becoming increasingly useful in the management and prognosis of complex, multiscale pathologies, including those attributed to the development of pulmonary vascular disease. However, diseases like pulmonary hypertension are heterogeneous, and affect both the proximal arteries and veins as well as the microcirculation. Simulation tools and the data used for model calibration are also inherently uncertain, requiring a full analysis of the sensitivity and uncertainty attributed to model inputs and outputs. Thus, this study quantifies model sensitivity and output uncertainty in a multiscale, pulse-wave propagation model of pulmonary hemodynamics. Our pulmonary circuit model consists of fifteen proximal arteries and twelve proximal veins, connected by a two-sided, structured tree model of the distal vasculature. We use polynomial chaos expansions to expedite the sensitivity and uncertainty quantification analyses and provide results for both the proximal and distal vasculature. Our analyses provide uncertainty in blood pressure, flow, and wave propagation phenomenon, as well as wall shear stress and cyclic stretch, both of which are important stimuli for endothelial cell mechanotransduction. We conclude that, while nearly all the parameters in our system have some influence on model predictions, the parameters describing the density of the microvascular beds have the largest effects on all simulated quantities in both the proximal and distal circulation.
format Online
Article
Text
id pubmed-10508834
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cornell University
record_format MEDLINE/PubMed
spelling pubmed-105088342023-09-20 Efficient Uncertainty Quantification in a Multiscale Model of Pulmonary Arterial and Venous Hemodynamics Colebank, M. J. Chesler, N.C. ArXiv Article Computational hemodynamics models are becoming increasingly useful in the management and prognosis of complex, multiscale pathologies, including those attributed to the development of pulmonary vascular disease. However, diseases like pulmonary hypertension are heterogeneous, and affect both the proximal arteries and veins as well as the microcirculation. Simulation tools and the data used for model calibration are also inherently uncertain, requiring a full analysis of the sensitivity and uncertainty attributed to model inputs and outputs. Thus, this study quantifies model sensitivity and output uncertainty in a multiscale, pulse-wave propagation model of pulmonary hemodynamics. Our pulmonary circuit model consists of fifteen proximal arteries and twelve proximal veins, connected by a two-sided, structured tree model of the distal vasculature. We use polynomial chaos expansions to expedite the sensitivity and uncertainty quantification analyses and provide results for both the proximal and distal vasculature. Our analyses provide uncertainty in blood pressure, flow, and wave propagation phenomenon, as well as wall shear stress and cyclic stretch, both of which are important stimuli for endothelial cell mechanotransduction. We conclude that, while nearly all the parameters in our system have some influence on model predictions, the parameters describing the density of the microvascular beds have the largest effects on all simulated quantities in both the proximal and distal circulation. Cornell University 2023-09-08 /pmc/articles/PMC10508834/ /pubmed/37731656 Text en https://creativecommons.org/licenses/by-sa/4.0/This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License (https://creativecommons.org/licenses/by-sa/4.0/) , which allows reusers to distribute, remix, adapt, and build upon the material in any medium or format, so long as attribution is given to the creator. The license allows for commercial use. If you remix, adapt, or build upon the material, you must license the modified material under identical terms.
spellingShingle Article
Colebank, M. J.
Chesler, N.C.
Efficient Uncertainty Quantification in a Multiscale Model of Pulmonary Arterial and Venous Hemodynamics
title Efficient Uncertainty Quantification in a Multiscale Model of Pulmonary Arterial and Venous Hemodynamics
title_full Efficient Uncertainty Quantification in a Multiscale Model of Pulmonary Arterial and Venous Hemodynamics
title_fullStr Efficient Uncertainty Quantification in a Multiscale Model of Pulmonary Arterial and Venous Hemodynamics
title_full_unstemmed Efficient Uncertainty Quantification in a Multiscale Model of Pulmonary Arterial and Venous Hemodynamics
title_short Efficient Uncertainty Quantification in a Multiscale Model of Pulmonary Arterial and Venous Hemodynamics
title_sort efficient uncertainty quantification in a multiscale model of pulmonary arterial and venous hemodynamics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10508834/
https://www.ncbi.nlm.nih.gov/pubmed/37731656
work_keys_str_mv AT colebankmj efficientuncertaintyquantificationinamultiscalemodelofpulmonaryarterialandvenoushemodynamics
AT cheslernc efficientuncertaintyquantificationinamultiscalemodelofpulmonaryarterialandvenoushemodynamics