Cargando…

Development and validation of an open-source tool for opportunistic screening of osteoporosis from hip CT images: a multicentre study of 978 hips

AIMS: This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. METHODS: The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from t...

Descripción completa

Detalles Bibliográficos
Autores principales: Uemura, Keisuke, Otake, Yoshito, Takashima, Kazuma, Hamada, Hidetoshi, Imagama, Takashi, Takao, Masaki, Sakai, Takashi, Sato, Yoshinobu, Okada, Seiji, Sugano, Nobuhiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Editorial Society of Bone & Joint Surgery 2023
Materias:
Hip
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10509772/
https://www.ncbi.nlm.nih.gov/pubmed/37728034
http://dx.doi.org/10.1302/2046-3758.129.BJR-2023-0115.R1
_version_ 1785107826445647872
author Uemura, Keisuke
Otake, Yoshito
Takashima, Kazuma
Hamada, Hidetoshi
Imagama, Takashi
Takao, Masaki
Sakai, Takashi
Sato, Yoshinobu
Okada, Seiji
Sugano, Nobuhiko
author_facet Uemura, Keisuke
Otake, Yoshito
Takashima, Kazuma
Hamada, Hidetoshi
Imagama, Takashi
Takao, Masaki
Sakai, Takashi
Sato, Yoshinobu
Okada, Seiji
Sugano, Nobuhiko
author_sort Uemura, Keisuke
collection PubMed
description AIMS: This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. METHODS: The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm(3)). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis. RESULTS: CT-aBMD was successfully measured in 976/978 hips (99.8%). A significant correlation was found between CT-aBMD and DXA-BMD (r = 0.941; p < 0.001). In the ROC analysis, the area under the curve to diagnose osteoporosis was 0.976. The diagnostic sensitivity and specificity were 88.9% and 96%, respectively, with the cutoff set at 0.625 g/cm(2). CONCLUSION: Accurate DXA-BMD measurements and diagnosis of osteoporosis were performed from CT images using the system developed herein. As the models are open-source, clinicians can use the proposed system to screen osteoporosis and determine the surgical strategy for hip surgery. Cite this article: Bone Joint Res 2023;12(9):590–597.
format Online
Article
Text
id pubmed-10509772
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The British Editorial Society of Bone & Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-105097722023-09-21 Development and validation of an open-source tool for opportunistic screening of osteoporosis from hip CT images: a multicentre study of 978 hips Uemura, Keisuke Otake, Yoshito Takashima, Kazuma Hamada, Hidetoshi Imagama, Takashi Takao, Masaki Sakai, Takashi Sato, Yoshinobu Okada, Seiji Sugano, Nobuhiko Bone Joint Res Hip AIMS: This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. METHODS: The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm(3)). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis. RESULTS: CT-aBMD was successfully measured in 976/978 hips (99.8%). A significant correlation was found between CT-aBMD and DXA-BMD (r = 0.941; p < 0.001). In the ROC analysis, the area under the curve to diagnose osteoporosis was 0.976. The diagnostic sensitivity and specificity were 88.9% and 96%, respectively, with the cutoff set at 0.625 g/cm(2). CONCLUSION: Accurate DXA-BMD measurements and diagnosis of osteoporosis were performed from CT images using the system developed herein. As the models are open-source, clinicians can use the proposed system to screen osteoporosis and determine the surgical strategy for hip surgery. Cite this article: Bone Joint Res 2023;12(9):590–597. The British Editorial Society of Bone & Joint Surgery 2023-09-20 /pmc/articles/PMC10509772/ /pubmed/37728034 http://dx.doi.org/10.1302/2046-3758.129.BJR-2023-0115.R1 Text en © 2023 Author(s) et al. https://creativecommons.org/licenses/by/4.0/https://online.boneandjoint.org.uk/TDM Open Access This article is distributed under the terms of the Creative Commons Attributions (CC BY 4.0) licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium or format, provided the original author and source are credited.
spellingShingle Hip
Uemura, Keisuke
Otake, Yoshito
Takashima, Kazuma
Hamada, Hidetoshi
Imagama, Takashi
Takao, Masaki
Sakai, Takashi
Sato, Yoshinobu
Okada, Seiji
Sugano, Nobuhiko
Development and validation of an open-source tool for opportunistic screening of osteoporosis from hip CT images: a multicentre study of 978 hips
title Development and validation of an open-source tool for opportunistic screening of osteoporosis from hip CT images: a multicentre study of 978 hips
title_full Development and validation of an open-source tool for opportunistic screening of osteoporosis from hip CT images: a multicentre study of 978 hips
title_fullStr Development and validation of an open-source tool for opportunistic screening of osteoporosis from hip CT images: a multicentre study of 978 hips
title_full_unstemmed Development and validation of an open-source tool for opportunistic screening of osteoporosis from hip CT images: a multicentre study of 978 hips
title_short Development and validation of an open-source tool for opportunistic screening of osteoporosis from hip CT images: a multicentre study of 978 hips
title_sort development and validation of an open-source tool for opportunistic screening of osteoporosis from hip ct images: a multicentre study of 978 hips
topic Hip
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10509772/
https://www.ncbi.nlm.nih.gov/pubmed/37728034
http://dx.doi.org/10.1302/2046-3758.129.BJR-2023-0115.R1
work_keys_str_mv AT uemurakeisuke developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT otakeyoshito developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT takashimakazuma developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT hamadahidetoshi developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT imagamatakashi developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT takaomasaki developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT sakaitakashi developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT satoyoshinobu developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT okadaseiji developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips
AT suganonobuhiko developmentandvalidationofanopensourcetoolforopportunisticscreeningofosteoporosisfromhipctimagesamulticentrestudyof978hips