Cargando…
Technique for liver separation using the modified liver hanging maneuver (LHM) in a case of thoraco-omphalopagus conjoined twins
INTRODUCTION: Conjoined twins are rare, high-stakes cases requiring complex management. This report presents thoraco-omphalopagus conjoined twins who shared parts of liver and abdominal wall. The main obstacle in separating these patients was liver fusion. PRESENTATION OF CASE: Two-year-old female c...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10509815/ https://www.ncbi.nlm.nih.gov/pubmed/37643564 http://dx.doi.org/10.1016/j.ijscr.2023.108613 |
_version_ | 1785107836154413056 |
---|---|
author | Tendean, Michael Lampus, Harsali Fransiscus Rendy, Leo Wijaya, Candy Panelewen, Jimmy |
author_facet | Tendean, Michael Lampus, Harsali Fransiscus Rendy, Leo Wijaya, Candy Panelewen, Jimmy |
author_sort | Tendean, Michael |
collection | PubMed |
description | INTRODUCTION: Conjoined twins are rare, high-stakes cases requiring complex management. This report presents thoraco-omphalopagus conjoined twins who shared parts of liver and abdominal wall. The main obstacle in separating these patients was liver fusion. PRESENTATION OF CASE: Two-year-old female conjoined twins presented with liver fusion between segments 2 and 3 in twin A and segments 2 and 4A in twin B. Liver separation was performed using the modified liver hanging maneuver. After separating the triangular ligaments and surrounding adhesions, a 12-Fr Foley catheter was inserted under the fused liver, suspending it upward and producing a clear separation plane. Liver separation required only 32 min. No notable bleeding or bile leakage was observed. DISCUSSION: The liver hanging maneuver was originally used as an adjunct technique for liver tumor hepatectomy. We used this technique to separate the fused livers in conjoined twins. The advantages of LHM include potentially reducing excess manipulation, which may result in parenchyma and vascular pedicle injury, and facilitating bleeding control, thereby reducing the operation time. CONCLUSION: The liver hanging maneuver using a conventional Foley catheter is a simple and useful method for separating fused livers in conjoined twins. |
format | Online Article Text |
id | pubmed-10509815 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-105098152023-09-21 Technique for liver separation using the modified liver hanging maneuver (LHM) in a case of thoraco-omphalopagus conjoined twins Tendean, Michael Lampus, Harsali Fransiscus Rendy, Leo Wijaya, Candy Panelewen, Jimmy Int J Surg Case Rep Case Report INTRODUCTION: Conjoined twins are rare, high-stakes cases requiring complex management. This report presents thoraco-omphalopagus conjoined twins who shared parts of liver and abdominal wall. The main obstacle in separating these patients was liver fusion. PRESENTATION OF CASE: Two-year-old female conjoined twins presented with liver fusion between segments 2 and 3 in twin A and segments 2 and 4A in twin B. Liver separation was performed using the modified liver hanging maneuver. After separating the triangular ligaments and surrounding adhesions, a 12-Fr Foley catheter was inserted under the fused liver, suspending it upward and producing a clear separation plane. Liver separation required only 32 min. No notable bleeding or bile leakage was observed. DISCUSSION: The liver hanging maneuver was originally used as an adjunct technique for liver tumor hepatectomy. We used this technique to separate the fused livers in conjoined twins. The advantages of LHM include potentially reducing excess manipulation, which may result in parenchyma and vascular pedicle injury, and facilitating bleeding control, thereby reducing the operation time. CONCLUSION: The liver hanging maneuver using a conventional Foley catheter is a simple and useful method for separating fused livers in conjoined twins. Elsevier 2023-08-17 /pmc/articles/PMC10509815/ /pubmed/37643564 http://dx.doi.org/10.1016/j.ijscr.2023.108613 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Tendean, Michael Lampus, Harsali Fransiscus Rendy, Leo Wijaya, Candy Panelewen, Jimmy Technique for liver separation using the modified liver hanging maneuver (LHM) in a case of thoraco-omphalopagus conjoined twins |
title | Technique for liver separation using the modified liver hanging maneuver (LHM) in a case of thoraco-omphalopagus conjoined twins |
title_full | Technique for liver separation using the modified liver hanging maneuver (LHM) in a case of thoraco-omphalopagus conjoined twins |
title_fullStr | Technique for liver separation using the modified liver hanging maneuver (LHM) in a case of thoraco-omphalopagus conjoined twins |
title_full_unstemmed | Technique for liver separation using the modified liver hanging maneuver (LHM) in a case of thoraco-omphalopagus conjoined twins |
title_short | Technique for liver separation using the modified liver hanging maneuver (LHM) in a case of thoraco-omphalopagus conjoined twins |
title_sort | technique for liver separation using the modified liver hanging maneuver (lhm) in a case of thoraco-omphalopagus conjoined twins |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10509815/ https://www.ncbi.nlm.nih.gov/pubmed/37643564 http://dx.doi.org/10.1016/j.ijscr.2023.108613 |
work_keys_str_mv | AT tendeanmichael techniqueforliverseparationusingthemodifiedliverhangingmaneuverlhminacaseofthoracoomphalopagusconjoinedtwins AT lampusharsalifransiscus techniqueforliverseparationusingthemodifiedliverhangingmaneuverlhminacaseofthoracoomphalopagusconjoinedtwins AT rendyleo techniqueforliverseparationusingthemodifiedliverhangingmaneuverlhminacaseofthoracoomphalopagusconjoinedtwins AT wijayacandy techniqueforliverseparationusingthemodifiedliverhangingmaneuverlhminacaseofthoracoomphalopagusconjoinedtwins AT panelewenjimmy techniqueforliverseparationusingthemodifiedliverhangingmaneuverlhminacaseofthoracoomphalopagusconjoinedtwins |