Cargando…

Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits

BACKGROUND: Electric field (E-field) modeling is a valuable method of elucidating the cortical target engagement from transcranial magnetic stimulation (TMS) and transcranial electrical stimulation (tES), but it is typically dependent on individual MRI scans. In this study, we systematically tested...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Jennifer Y., Van Hoornweder, Sybren, Sege, Christopher T., Antonucci, Michael U., McTeague, Lisa M., Caulfield, Kevin A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10510202/
https://www.ncbi.nlm.nih.gov/pubmed/37736398
http://dx.doi.org/10.3389/fncir.2023.1214959
_version_ 1785107916027592704
author Cho, Jennifer Y.
Van Hoornweder, Sybren
Sege, Christopher T.
Antonucci, Michael U.
McTeague, Lisa M.
Caulfield, Kevin A.
author_facet Cho, Jennifer Y.
Van Hoornweder, Sybren
Sege, Christopher T.
Antonucci, Michael U.
McTeague, Lisa M.
Caulfield, Kevin A.
author_sort Cho, Jennifer Y.
collection PubMed
description BACKGROUND: Electric field (E-field) modeling is a valuable method of elucidating the cortical target engagement from transcranial magnetic stimulation (TMS) and transcranial electrical stimulation (tES), but it is typically dependent on individual MRI scans. In this study, we systematically tested whether E-field models in template MNI-152 and Ernie scans can reliably approximate group-level E-fields induced in N = 195 individuals across 5 diagnoses (healthy, alcohol use disorder, tobacco use disorder, anxiety, depression). METHODS: We computed 788 E-field models using the CHARM–SimNIBS 4.0.0 pipeline with 4 E-field models per participant (motor and prefrontal targets for TMS and tES). We additionally calculated permutation analyses to determine the point of stability of E-fields to assess whether the 152 brains represented in the MNI-152 template is sufficient. RESULTS: Group-level E-fields did not significantly differ between the individual vs. MNI-152 template and Ernie scans for any stimulation modality or location (p > 0.05). However, TMS-induced E-field magnitudes significantly varied by diagnosis; individuals with generalized anxiety had significantly higher prefrontal and motor E-field magnitudes than healthy controls and those with alcohol use disorder and depression (p < 0.001). The point of stability for group-level E-field magnitudes ranged from 42 (motor tES) to 52 participants (prefrontal TMS). CONCLUSION: MNI-152 and Ernie models reliably estimate group-average TMS and tES-induced E-fields transdiagnostically. The MNI-152 template includes sufficient scans to control for interindividual anatomical differences (i.e., above the point of stability). Taken together, using the MNI-152 and Ernie brains to approximate group-level E-fields is a valid and reliable approach.
format Online
Article
Text
id pubmed-10510202
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-105102022023-09-21 Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits Cho, Jennifer Y. Van Hoornweder, Sybren Sege, Christopher T. Antonucci, Michael U. McTeague, Lisa M. Caulfield, Kevin A. Front Neural Circuits Neural Circuits BACKGROUND: Electric field (E-field) modeling is a valuable method of elucidating the cortical target engagement from transcranial magnetic stimulation (TMS) and transcranial electrical stimulation (tES), but it is typically dependent on individual MRI scans. In this study, we systematically tested whether E-field models in template MNI-152 and Ernie scans can reliably approximate group-level E-fields induced in N = 195 individuals across 5 diagnoses (healthy, alcohol use disorder, tobacco use disorder, anxiety, depression). METHODS: We computed 788 E-field models using the CHARM–SimNIBS 4.0.0 pipeline with 4 E-field models per participant (motor and prefrontal targets for TMS and tES). We additionally calculated permutation analyses to determine the point of stability of E-fields to assess whether the 152 brains represented in the MNI-152 template is sufficient. RESULTS: Group-level E-fields did not significantly differ between the individual vs. MNI-152 template and Ernie scans for any stimulation modality or location (p > 0.05). However, TMS-induced E-field magnitudes significantly varied by diagnosis; individuals with generalized anxiety had significantly higher prefrontal and motor E-field magnitudes than healthy controls and those with alcohol use disorder and depression (p < 0.001). The point of stability for group-level E-field magnitudes ranged from 42 (motor tES) to 52 participants (prefrontal TMS). CONCLUSION: MNI-152 and Ernie models reliably estimate group-average TMS and tES-induced E-fields transdiagnostically. The MNI-152 template includes sufficient scans to control for interindividual anatomical differences (i.e., above the point of stability). Taken together, using the MNI-152 and Ernie brains to approximate group-level E-fields is a valid and reliable approach. Frontiers Media S.A. 2023-09-06 /pmc/articles/PMC10510202/ /pubmed/37736398 http://dx.doi.org/10.3389/fncir.2023.1214959 Text en Copyright © 2023 Cho, Van Hoornweder, Sege, Antonucci, McTeague and Caulfield. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neural Circuits
Cho, Jennifer Y.
Van Hoornweder, Sybren
Sege, Christopher T.
Antonucci, Michael U.
McTeague, Lisa M.
Caulfield, Kevin A.
Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits
title Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits
title_full Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits
title_fullStr Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits
title_full_unstemmed Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits
title_short Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits
title_sort template mri scans reliably approximate individual and group-level tes and tms electric fields induced in motor and prefrontal circuits
topic Neural Circuits
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10510202/
https://www.ncbi.nlm.nih.gov/pubmed/37736398
http://dx.doi.org/10.3389/fncir.2023.1214959
work_keys_str_mv AT chojennifery templatemriscansreliablyapproximateindividualandgroupleveltesandtmselectricfieldsinducedinmotorandprefrontalcircuits
AT vanhoornwedersybren templatemriscansreliablyapproximateindividualandgroupleveltesandtmselectricfieldsinducedinmotorandprefrontalcircuits
AT segechristophert templatemriscansreliablyapproximateindividualandgroupleveltesandtmselectricfieldsinducedinmotorandprefrontalcircuits
AT antonuccimichaelu templatemriscansreliablyapproximateindividualandgroupleveltesandtmselectricfieldsinducedinmotorandprefrontalcircuits
AT mcteaguelisam templatemriscansreliablyapproximateindividualandgroupleveltesandtmselectricfieldsinducedinmotorandprefrontalcircuits
AT caulfieldkevina templatemriscansreliablyapproximateindividualandgroupleveltesandtmselectricfieldsinducedinmotorandprefrontalcircuits