Cargando…

Early Detection of Risk of Neo-Sinus Blood Stasis Post-Transcatheter Aortic Valve Replacement Using Personalized Hemodynamic Analysis

BACKGROUND: Despite the demonstrated benefits of transcatheter aortic valve replacement (TAVR), subclinical leaflet thrombosis and hypoattenuated leaflet thickening are commonly seen as initial indications of decreased valve durability and augmented risk of transient ischemic attack. METHODS: We dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Khodaei, Seyedvahid, Abdelkhalek, Mohamed, Maftoon, Nima, Emadi, Ali, Keshavarz-Motamed, Zahra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10512011/
https://www.ncbi.nlm.nih.gov/pubmed/37745677
http://dx.doi.org/10.1016/j.shj.2023.100180
_version_ 1785108271694086144
author Khodaei, Seyedvahid
Abdelkhalek, Mohamed
Maftoon, Nima
Emadi, Ali
Keshavarz-Motamed, Zahra
author_facet Khodaei, Seyedvahid
Abdelkhalek, Mohamed
Maftoon, Nima
Emadi, Ali
Keshavarz-Motamed, Zahra
author_sort Khodaei, Seyedvahid
collection PubMed
description BACKGROUND: Despite the demonstrated benefits of transcatheter aortic valve replacement (TAVR), subclinical leaflet thrombosis and hypoattenuated leaflet thickening are commonly seen as initial indications of decreased valve durability and augmented risk of transient ischemic attack. METHODS: We developed a multiscale patient-specific computational framework to quantify metrics of global circulatory function, metrics of global cardiac function, and local cardiac fluid dynamics of the aortic root and coronary arteries. RESULTS: Based on our findings, TAVR might be associated with a high risk of blood stagnation in the neo-sinus region due to the lack of sufficient blood flow washout during the diastole phase (e.g., maximum blood stasis volume increased by 13, 8, and 2.7 fold in the left coronary cusp, right coronary cusp, and noncoronary cusp, respectively [N = 26]). Moreover, in some patients, TAVR might not be associated with left ventricle load relief (e.g., left ventricle load reduced only by 1.2 % [N = 26]) and diastolic coronary flow improvement (e.g., maximum coronary flow reduced by 4.94%, 15.05%, and 23.59% in the left anterior descending, left circumflex coronary artery, and right coronary artery, respectively, [N = 26]). CONCLUSIONS: The transvalvular pressure gradient amelioration after TAVR might not translate into adequate sinus blood washout, optimal coronary flow, and reduced cardiac stress. Noninvasive personalized computational modeling can facilitate the determination of the most effective revascularization strategy pre-TAVR and monitor leaflet thrombosis and coronary plaque progression post-TAVR.
format Online
Article
Text
id pubmed-10512011
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105120112023-09-22 Early Detection of Risk of Neo-Sinus Blood Stasis Post-Transcatheter Aortic Valve Replacement Using Personalized Hemodynamic Analysis Khodaei, Seyedvahid Abdelkhalek, Mohamed Maftoon, Nima Emadi, Ali Keshavarz-Motamed, Zahra Struct Heart Original Research BACKGROUND: Despite the demonstrated benefits of transcatheter aortic valve replacement (TAVR), subclinical leaflet thrombosis and hypoattenuated leaflet thickening are commonly seen as initial indications of decreased valve durability and augmented risk of transient ischemic attack. METHODS: We developed a multiscale patient-specific computational framework to quantify metrics of global circulatory function, metrics of global cardiac function, and local cardiac fluid dynamics of the aortic root and coronary arteries. RESULTS: Based on our findings, TAVR might be associated with a high risk of blood stagnation in the neo-sinus region due to the lack of sufficient blood flow washout during the diastole phase (e.g., maximum blood stasis volume increased by 13, 8, and 2.7 fold in the left coronary cusp, right coronary cusp, and noncoronary cusp, respectively [N = 26]). Moreover, in some patients, TAVR might not be associated with left ventricle load relief (e.g., left ventricle load reduced only by 1.2 % [N = 26]) and diastolic coronary flow improvement (e.g., maximum coronary flow reduced by 4.94%, 15.05%, and 23.59% in the left anterior descending, left circumflex coronary artery, and right coronary artery, respectively, [N = 26]). CONCLUSIONS: The transvalvular pressure gradient amelioration after TAVR might not translate into adequate sinus blood washout, optimal coronary flow, and reduced cardiac stress. Noninvasive personalized computational modeling can facilitate the determination of the most effective revascularization strategy pre-TAVR and monitor leaflet thrombosis and coronary plaque progression post-TAVR. Elsevier 2023-04-28 /pmc/articles/PMC10512011/ /pubmed/37745677 http://dx.doi.org/10.1016/j.shj.2023.100180 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Khodaei, Seyedvahid
Abdelkhalek, Mohamed
Maftoon, Nima
Emadi, Ali
Keshavarz-Motamed, Zahra
Early Detection of Risk of Neo-Sinus Blood Stasis Post-Transcatheter Aortic Valve Replacement Using Personalized Hemodynamic Analysis
title Early Detection of Risk of Neo-Sinus Blood Stasis Post-Transcatheter Aortic Valve Replacement Using Personalized Hemodynamic Analysis
title_full Early Detection of Risk of Neo-Sinus Blood Stasis Post-Transcatheter Aortic Valve Replacement Using Personalized Hemodynamic Analysis
title_fullStr Early Detection of Risk of Neo-Sinus Blood Stasis Post-Transcatheter Aortic Valve Replacement Using Personalized Hemodynamic Analysis
title_full_unstemmed Early Detection of Risk of Neo-Sinus Blood Stasis Post-Transcatheter Aortic Valve Replacement Using Personalized Hemodynamic Analysis
title_short Early Detection of Risk of Neo-Sinus Blood Stasis Post-Transcatheter Aortic Valve Replacement Using Personalized Hemodynamic Analysis
title_sort early detection of risk of neo-sinus blood stasis post-transcatheter aortic valve replacement using personalized hemodynamic analysis
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10512011/
https://www.ncbi.nlm.nih.gov/pubmed/37745677
http://dx.doi.org/10.1016/j.shj.2023.100180
work_keys_str_mv AT khodaeiseyedvahid earlydetectionofriskofneosinusbloodstasisposttranscatheteraorticvalvereplacementusingpersonalizedhemodynamicanalysis
AT abdelkhalekmohamed earlydetectionofriskofneosinusbloodstasisposttranscatheteraorticvalvereplacementusingpersonalizedhemodynamicanalysis
AT maftoonnima earlydetectionofriskofneosinusbloodstasisposttranscatheteraorticvalvereplacementusingpersonalizedhemodynamicanalysis
AT emadiali earlydetectionofriskofneosinusbloodstasisposttranscatheteraorticvalvereplacementusingpersonalizedhemodynamicanalysis
AT keshavarzmotamedzahra earlydetectionofriskofneosinusbloodstasisposttranscatheteraorticvalvereplacementusingpersonalizedhemodynamicanalysis