Cargando…

Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis

Introduction: Anterior cervical discectomy and fusion (ACDF) is a standard procedure for treating symptomatic cervical degenerative disease. The cage and plate constructs (CPCs) are widely employed in ACDF to maintain spinal stability and to provide immediate support. However, several instrument-rel...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yang, Liu, Yang, Zhang, Aobo, Han, Qing, Jiao, Jianhang, Chen, Hao, Gong, Xuqiang, Luo, Wangwang, Yue, Jing, Zhao, Xue, Wang, Jincheng, Wu, Minfei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10512836/
https://www.ncbi.nlm.nih.gov/pubmed/37744254
http://dx.doi.org/10.3389/fbioe.2023.1229210
_version_ 1785108444822372352
author Wang, Yang
Liu, Yang
Zhang, Aobo
Han, Qing
Jiao, Jianhang
Chen, Hao
Gong, Xuqiang
Luo, Wangwang
Yue, Jing
Zhao, Xue
Wang, Jincheng
Wu, Minfei
author_facet Wang, Yang
Liu, Yang
Zhang, Aobo
Han, Qing
Jiao, Jianhang
Chen, Hao
Gong, Xuqiang
Luo, Wangwang
Yue, Jing
Zhao, Xue
Wang, Jincheng
Wu, Minfei
author_sort Wang, Yang
collection PubMed
description Introduction: Anterior cervical discectomy and fusion (ACDF) is a standard procedure for treating symptomatic cervical degenerative disease. The cage and plate constructs (CPCs) are widely employed in ACDF to maintain spinal stability and to provide immediate support. However, several instrument-related complications such as dysphagia, cage subsidence, and adjacent segment degeneration have been reported in the previous literature. This study aimed to design a novel individualized zero-profile (NIZP) cage and evaluate its potential to enhance the biomechanical performance between the instrument and the cervical spine. Methods: The intact finite element models of C3-C7 were constructed and validated. A NIZP cage was designed based on the anatomical parameters of the subject’s C5/6. The ACDF procedure was simulated and the CPCs and NIZP cage were implanted separately. The range of motion (ROM), intradiscal pressure (IDP), and peak von Mises stresses of annulus fibrosus were compared between the two surgical models after ACDF under four motion conditions. Additionally, the biomechanical performance of the CPCs and NIZP cage were evaluated. Results: Compared with the intact model, the ROM of the surgical segment was significantly decreased for both surgical models under four motion conditions. Additionally, there was an increase in IDP and peak von Mises stress of annulus fibrosus in the adjacent segment. The NIZP cage had a more subtle impact on postoperative IDP and peak von Mises stress of annulus fibrosus in adjacent segments compared to CPCs. Meanwhile, the peak von Mises stresses of the NIZP cage were reduced by 90.0–120.0 MPa, and the average von Mises stresses were reduced by 12.61–17.56 MPa under different motion conditions. Regarding the fixation screws, the peak von Mises stresses in the screws of the NIZP cage increased by 10.0–40.0 MPa and the average von Mises stresses increased by 2.37–10.10 MPa. Conclusion: The NIZP cage could effectively reconstruct spinal stability in ACDF procedure by finite element study. Compared with the CPCs, the NIZP cage had better biomechanical performance, with a lower stress distribution on the cage and a more moderate effect on the adjacent segmental discs. Therefore, the NIZP cage could prevent postoperative dysphagia as well as decrease the risk of subsidence and adjacent disc degeneration following ACDF. In addition, this study could serve as a valuable reference for the development of personalized instruments.
format Online
Article
Text
id pubmed-10512836
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-105128362023-09-22 Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis Wang, Yang Liu, Yang Zhang, Aobo Han, Qing Jiao, Jianhang Chen, Hao Gong, Xuqiang Luo, Wangwang Yue, Jing Zhao, Xue Wang, Jincheng Wu, Minfei Front Bioeng Biotechnol Bioengineering and Biotechnology Introduction: Anterior cervical discectomy and fusion (ACDF) is a standard procedure for treating symptomatic cervical degenerative disease. The cage and plate constructs (CPCs) are widely employed in ACDF to maintain spinal stability and to provide immediate support. However, several instrument-related complications such as dysphagia, cage subsidence, and adjacent segment degeneration have been reported in the previous literature. This study aimed to design a novel individualized zero-profile (NIZP) cage and evaluate its potential to enhance the biomechanical performance between the instrument and the cervical spine. Methods: The intact finite element models of C3-C7 were constructed and validated. A NIZP cage was designed based on the anatomical parameters of the subject’s C5/6. The ACDF procedure was simulated and the CPCs and NIZP cage were implanted separately. The range of motion (ROM), intradiscal pressure (IDP), and peak von Mises stresses of annulus fibrosus were compared between the two surgical models after ACDF under four motion conditions. Additionally, the biomechanical performance of the CPCs and NIZP cage were evaluated. Results: Compared with the intact model, the ROM of the surgical segment was significantly decreased for both surgical models under four motion conditions. Additionally, there was an increase in IDP and peak von Mises stress of annulus fibrosus in the adjacent segment. The NIZP cage had a more subtle impact on postoperative IDP and peak von Mises stress of annulus fibrosus in adjacent segments compared to CPCs. Meanwhile, the peak von Mises stresses of the NIZP cage were reduced by 90.0–120.0 MPa, and the average von Mises stresses were reduced by 12.61–17.56 MPa under different motion conditions. Regarding the fixation screws, the peak von Mises stresses in the screws of the NIZP cage increased by 10.0–40.0 MPa and the average von Mises stresses increased by 2.37–10.10 MPa. Conclusion: The NIZP cage could effectively reconstruct spinal stability in ACDF procedure by finite element study. Compared with the CPCs, the NIZP cage had better biomechanical performance, with a lower stress distribution on the cage and a more moderate effect on the adjacent segmental discs. Therefore, the NIZP cage could prevent postoperative dysphagia as well as decrease the risk of subsidence and adjacent disc degeneration following ACDF. In addition, this study could serve as a valuable reference for the development of personalized instruments. Frontiers Media S.A. 2023-09-07 /pmc/articles/PMC10512836/ /pubmed/37744254 http://dx.doi.org/10.3389/fbioe.2023.1229210 Text en Copyright © 2023 Wang, Liu, Zhang, Han, Jiao, Chen, Gong, Luo, Yue, Zhao, Wang and Wu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Wang, Yang
Liu, Yang
Zhang, Aobo
Han, Qing
Jiao, Jianhang
Chen, Hao
Gong, Xuqiang
Luo, Wangwang
Yue, Jing
Zhao, Xue
Wang, Jincheng
Wu, Minfei
Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
title Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
title_full Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
title_fullStr Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
title_full_unstemmed Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
title_short Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
title_sort biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10512836/
https://www.ncbi.nlm.nih.gov/pubmed/37744254
http://dx.doi.org/10.3389/fbioe.2023.1229210
work_keys_str_mv AT wangyang biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT liuyang biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT zhangaobo biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT hanqing biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT jiaojianhang biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT chenhao biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT gongxuqiang biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT luowangwang biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT yuejing biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT zhaoxue biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT wangjincheng biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT wuminfei biomechanicalevaluationofanovelindividualizedzeroprofilecageforanteriorcervicaldiscectomyandfusionafiniteelementanalysis