Cargando…
Noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography
It is crucial to develop practical and noninvasive methods to assess the functional beta‐cell mass in a donor pancreas, in which monitoring and precise evaluation is challenging. A patient with type 1 diabetes underwent noninvasive imaging following simultaneous kidney–pancreas transplantation with...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10512903/ https://www.ncbi.nlm.nih.gov/pubmed/37377043 http://dx.doi.org/10.1111/jdi.14045 |
_version_ | 1785108458914185216 |
---|---|
author | Murakami, Takaaki Nakamura, Toshihiro Fujimoto, Hiroyuki Fujikura, Junji Shimizu, Yoichi Miyake, Kanae K. Otani, Daisuke Sakaki, Kentaro Kiyobayashi, Sakura Anazawa, Takayuki Nakamoto, Yuji Inagaki, Nobuya |
author_facet | Murakami, Takaaki Nakamura, Toshihiro Fujimoto, Hiroyuki Fujikura, Junji Shimizu, Yoichi Miyake, Kanae K. Otani, Daisuke Sakaki, Kentaro Kiyobayashi, Sakura Anazawa, Takayuki Nakamoto, Yuji Inagaki, Nobuya |
author_sort | Murakami, Takaaki |
collection | PubMed |
description | It is crucial to develop practical and noninvasive methods to assess the functional beta‐cell mass in a donor pancreas, in which monitoring and precise evaluation is challenging. A patient with type 1 diabetes underwent noninvasive imaging following simultaneous kidney–pancreas transplantation with positron emission tomography/computed tomography (PET/CT) using an exendin‐based probe, [(18)F]FB(ePEG12)12‐exendin‐4. Following transplantation, PET imaging with [(18)F]FB(ePEG12)12‐exendin‐4 revealed simultaneous and distinct accumulations in the donor and native pancreases. The pancreases were outlined at a reasonable distance from the surrounding organs using [(18)F]FB(ePEG12)12‐exendin‐4 whole‐body maximum intensity projection and axial PET images. At 1 and 2 h after [(18)F]FB(ePEG12)12‐exendin‐4 administration, the mean standardized uptake values were 2.96 and 3.08, respectively, in the donor pancreas and 1.97 and 2.25, respectively, in the native pancreas. [(18)F]FB(ePEG12)12‐exendin‐4 positron emission tomography imaging allowed repeatable and quantitative assessment of beta‐cell mass following simultaneous kidney–pancreas transplantation. |
format | Online Article Text |
id | pubmed-10512903 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-105129032023-09-22 Noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography Murakami, Takaaki Nakamura, Toshihiro Fujimoto, Hiroyuki Fujikura, Junji Shimizu, Yoichi Miyake, Kanae K. Otani, Daisuke Sakaki, Kentaro Kiyobayashi, Sakura Anazawa, Takayuki Nakamoto, Yuji Inagaki, Nobuya J Diabetes Investig Articles It is crucial to develop practical and noninvasive methods to assess the functional beta‐cell mass in a donor pancreas, in which monitoring and precise evaluation is challenging. A patient with type 1 diabetes underwent noninvasive imaging following simultaneous kidney–pancreas transplantation with positron emission tomography/computed tomography (PET/CT) using an exendin‐based probe, [(18)F]FB(ePEG12)12‐exendin‐4. Following transplantation, PET imaging with [(18)F]FB(ePEG12)12‐exendin‐4 revealed simultaneous and distinct accumulations in the donor and native pancreases. The pancreases were outlined at a reasonable distance from the surrounding organs using [(18)F]FB(ePEG12)12‐exendin‐4 whole‐body maximum intensity projection and axial PET images. At 1 and 2 h after [(18)F]FB(ePEG12)12‐exendin‐4 administration, the mean standardized uptake values were 2.96 and 3.08, respectively, in the donor pancreas and 1.97 and 2.25, respectively, in the native pancreas. [(18)F]FB(ePEG12)12‐exendin‐4 positron emission tomography imaging allowed repeatable and quantitative assessment of beta‐cell mass following simultaneous kidney–pancreas transplantation. John Wiley and Sons Inc. 2023-06-28 /pmc/articles/PMC10512903/ /pubmed/37377043 http://dx.doi.org/10.1111/jdi.14045 Text en © 2023 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Articles Murakami, Takaaki Nakamura, Toshihiro Fujimoto, Hiroyuki Fujikura, Junji Shimizu, Yoichi Miyake, Kanae K. Otani, Daisuke Sakaki, Kentaro Kiyobayashi, Sakura Anazawa, Takayuki Nakamoto, Yuji Inagaki, Nobuya Noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography |
title | Noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography |
title_full | Noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography |
title_fullStr | Noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography |
title_full_unstemmed | Noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography |
title_short | Noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography |
title_sort | noninvasive evaluation of donor and native pancreases following simultaneous pancreas–kidney transplantation using positron emission tomography/computed tomography |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10512903/ https://www.ncbi.nlm.nih.gov/pubmed/37377043 http://dx.doi.org/10.1111/jdi.14045 |
work_keys_str_mv | AT murakamitakaaki noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT nakamuratoshihiro noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT fujimotohiroyuki noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT fujikurajunji noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT shimizuyoichi noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT miyakekanaek noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT otanidaisuke noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT sakakikentaro noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT kiyobayashisakura noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT anazawatakayuki noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT nakamotoyuji noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography AT inagakinobuya noninvasiveevaluationofdonorandnativepancreasesfollowingsimultaneouspancreaskidneytransplantationusingpositronemissiontomographycomputedtomography |