Allergy patient-specific IgE antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°C

The detection of allergen-specific IgE antibodies is an important biomarker for the diagnosis and treatment monitoring of allergic diseases. And the pre-analytical phase is an important part of the overall quality of the laboratory. In this study, 44 patients with allergic diseases (including 23 pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Zhifeng, Zhu, Huiqing, Xiao, Lexin, Liu, Tingting, Gan, Hui, Lin, Runpei, Luo, Wenting, Sun, Baoqing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10513756/
https://www.ncbi.nlm.nih.gov/pubmed/37744695
http://dx.doi.org/10.3389/falgy.2023.1239924
_version_ 1785108587637374976
author Huang, Zhifeng
Zhu, Huiqing
Xiao, Lexin
Liu, Tingting
Gan, Hui
Lin, Runpei
Luo, Wenting
Sun, Baoqing
author_facet Huang, Zhifeng
Zhu, Huiqing
Xiao, Lexin
Liu, Tingting
Gan, Hui
Lin, Runpei
Luo, Wenting
Sun, Baoqing
author_sort Huang, Zhifeng
collection PubMed
description The detection of allergen-specific IgE antibodies is an important biomarker for the diagnosis and treatment monitoring of allergic diseases. And the pre-analytical phase is an important part of the overall quality of the laboratory. In this study, 44 patients with allergic diseases (including 23 patients with allergic rhinitis, 12 patients with allergic rhinitis and asthma, and 9 patients with allergic dermatitis) were included in the outpatient center of the Department of Allergy, the First Affiliated Hospital of Guangzhou Medical University. We mixed the serums of the above 44 patients (approximately 0.8 ml of serum volume per patient) into a large volume of serum pool (about 35 ml in total) and divided into 26 parts. And 26 serum samples were stored at 4 different temperatures for 90 days to observe the stability of sIgE antibodies to 16 allergens in serum. The results show that serum sIgE antibody titers in patients with allergic diseases show significant stability during 90 days of storage, even at room temperature. Good stability even after up to 10 freeze-thaw cycles under low temperature storage conditions.
format Online
Article
Text
id pubmed-10513756
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-105137562023-09-22 Allergy patient-specific IgE antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°C Huang, Zhifeng Zhu, Huiqing Xiao, Lexin Liu, Tingting Gan, Hui Lin, Runpei Luo, Wenting Sun, Baoqing Front Allergy Allergy The detection of allergen-specific IgE antibodies is an important biomarker for the diagnosis and treatment monitoring of allergic diseases. And the pre-analytical phase is an important part of the overall quality of the laboratory. In this study, 44 patients with allergic diseases (including 23 patients with allergic rhinitis, 12 patients with allergic rhinitis and asthma, and 9 patients with allergic dermatitis) were included in the outpatient center of the Department of Allergy, the First Affiliated Hospital of Guangzhou Medical University. We mixed the serums of the above 44 patients (approximately 0.8 ml of serum volume per patient) into a large volume of serum pool (about 35 ml in total) and divided into 26 parts. And 26 serum samples were stored at 4 different temperatures for 90 days to observe the stability of sIgE antibodies to 16 allergens in serum. The results show that serum sIgE antibody titers in patients with allergic diseases show significant stability during 90 days of storage, even at room temperature. Good stability even after up to 10 freeze-thaw cycles under low temperature storage conditions. Frontiers Media S.A. 2023-09-07 /pmc/articles/PMC10513756/ /pubmed/37744695 http://dx.doi.org/10.3389/falgy.2023.1239924 Text en © 2023 Huang, Zhu, Xiao, Liu, Gan, Lin, Luo and Sun. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Allergy
Huang, Zhifeng
Zhu, Huiqing
Xiao, Lexin
Liu, Tingting
Gan, Hui
Lin, Runpei
Luo, Wenting
Sun, Baoqing
Allergy patient-specific IgE antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°C
title Allergy patient-specific IgE antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°C
title_full Allergy patient-specific IgE antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°C
title_fullStr Allergy patient-specific IgE antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°C
title_full_unstemmed Allergy patient-specific IgE antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°C
title_short Allergy patient-specific IgE antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°C
title_sort allergy patient-specific ige antibody shows significantly stability during 3 months of storage at multiple temperatures from −80 to 25°c
topic Allergy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10513756/
https://www.ncbi.nlm.nih.gov/pubmed/37744695
http://dx.doi.org/10.3389/falgy.2023.1239924
work_keys_str_mv AT huangzhifeng allergypatientspecificigeantibodyshowssignificantlystabilityduring3monthsofstorageatmultipletemperaturesfrom80to25c
AT zhuhuiqing allergypatientspecificigeantibodyshowssignificantlystabilityduring3monthsofstorageatmultipletemperaturesfrom80to25c
AT xiaolexin allergypatientspecificigeantibodyshowssignificantlystabilityduring3monthsofstorageatmultipletemperaturesfrom80to25c
AT liutingting allergypatientspecificigeantibodyshowssignificantlystabilityduring3monthsofstorageatmultipletemperaturesfrom80to25c
AT ganhui allergypatientspecificigeantibodyshowssignificantlystabilityduring3monthsofstorageatmultipletemperaturesfrom80to25c
AT linrunpei allergypatientspecificigeantibodyshowssignificantlystabilityduring3monthsofstorageatmultipletemperaturesfrom80to25c
AT luowenting allergypatientspecificigeantibodyshowssignificantlystabilityduring3monthsofstorageatmultipletemperaturesfrom80to25c
AT sunbaoqing allergypatientspecificigeantibodyshowssignificantlystabilityduring3monthsofstorageatmultipletemperaturesfrom80to25c