Cargando…

Impact of the COVID-19 Pandemic on Iron Overload Assessment by MRI in Patients with Hemoglobinopathies: The E-MIOT Network Experience

Background. The E-MIOT (Extension-Myocardial Iron Overload in Thalassemia) project is an Italian Network assuring high-quality quantification of tissue iron overload by magnetic resonance imaging (MRI). We evaluated the impact of the COVID-19 pandemic on E-MIOT services. Methods. The activity of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Meloni, Antonella, Pistoia, Laura, Lupi, Amalia, Righi, Riccardo, Vallone, Antonino, Missere, Massimiliano, Renne, Stefania, Fina, Priscilla, Riva, Ada, Gamberini, Maria Rita, Cecinati, Valerio, Sorrentino, Francesco, Rosso, Rosamaria, Messina, Giuseppe, Ricchi, Paolo, Positano, Vincenzo, Mavrogeni, Sophie, Quaia, Emilio, Cademartiri, Filippo, Pepe, Alessia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10514849/
https://www.ncbi.nlm.nih.gov/pubmed/37736989
http://dx.doi.org/10.3390/tomography9050136
_version_ 1785108815624011776
author Meloni, Antonella
Pistoia, Laura
Lupi, Amalia
Righi, Riccardo
Vallone, Antonino
Missere, Massimiliano
Renne, Stefania
Fina, Priscilla
Riva, Ada
Gamberini, Maria Rita
Cecinati, Valerio
Sorrentino, Francesco
Rosso, Rosamaria
Messina, Giuseppe
Ricchi, Paolo
Positano, Vincenzo
Mavrogeni, Sophie
Quaia, Emilio
Cademartiri, Filippo
Pepe, Alessia
author_facet Meloni, Antonella
Pistoia, Laura
Lupi, Amalia
Righi, Riccardo
Vallone, Antonino
Missere, Massimiliano
Renne, Stefania
Fina, Priscilla
Riva, Ada
Gamberini, Maria Rita
Cecinati, Valerio
Sorrentino, Francesco
Rosso, Rosamaria
Messina, Giuseppe
Ricchi, Paolo
Positano, Vincenzo
Mavrogeni, Sophie
Quaia, Emilio
Cademartiri, Filippo
Pepe, Alessia
author_sort Meloni, Antonella
collection PubMed
description Background. The E-MIOT (Extension-Myocardial Iron Overload in Thalassemia) project is an Italian Network assuring high-quality quantification of tissue iron overload by magnetic resonance imaging (MRI). We evaluated the impact of the COVID-19 pandemic on E-MIOT services. Methods. The activity of the E-MIOT Network MRI centers in the year 2020 was compared with that of 2019. A survey evaluated whether the availability of MRI slots for patients with hemoglobinopathies was reduced and why. Results. The total number of MRI scans was 656 in 2019 and 350 in 2020, with an overall decline of 46.4% (first MRI: 71.7%, follow-up MRI: 36.9%), a marked decline (86.9%) in the period March–June 2020, and a reduction in the gap between the two years in the period July–September. A new drop (41.4%) was recorded in the period October–December for two centers, due to the general reduction in the total amount of MRIs/day for sanitization procedures. In some centers, patients refused MRI scans for fear of getting COVID. Drops in the MRI services >80% were found for patients coming from a region without an active MRI site. Conclusions. The COVID-19 pandemic had a strong negative impact on MRI multi-organ iron quantification, with a worsening in the management of patients with hemoglobinopathies.
format Online
Article
Text
id pubmed-10514849
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105148492023-09-23 Impact of the COVID-19 Pandemic on Iron Overload Assessment by MRI in Patients with Hemoglobinopathies: The E-MIOT Network Experience Meloni, Antonella Pistoia, Laura Lupi, Amalia Righi, Riccardo Vallone, Antonino Missere, Massimiliano Renne, Stefania Fina, Priscilla Riva, Ada Gamberini, Maria Rita Cecinati, Valerio Sorrentino, Francesco Rosso, Rosamaria Messina, Giuseppe Ricchi, Paolo Positano, Vincenzo Mavrogeni, Sophie Quaia, Emilio Cademartiri, Filippo Pepe, Alessia Tomography Article Background. The E-MIOT (Extension-Myocardial Iron Overload in Thalassemia) project is an Italian Network assuring high-quality quantification of tissue iron overload by magnetic resonance imaging (MRI). We evaluated the impact of the COVID-19 pandemic on E-MIOT services. Methods. The activity of the E-MIOT Network MRI centers in the year 2020 was compared with that of 2019. A survey evaluated whether the availability of MRI slots for patients with hemoglobinopathies was reduced and why. Results. The total number of MRI scans was 656 in 2019 and 350 in 2020, with an overall decline of 46.4% (first MRI: 71.7%, follow-up MRI: 36.9%), a marked decline (86.9%) in the period March–June 2020, and a reduction in the gap between the two years in the period July–September. A new drop (41.4%) was recorded in the period October–December for two centers, due to the general reduction in the total amount of MRIs/day for sanitization procedures. In some centers, patients refused MRI scans for fear of getting COVID. Drops in the MRI services >80% were found for patients coming from a region without an active MRI site. Conclusions. The COVID-19 pandemic had a strong negative impact on MRI multi-organ iron quantification, with a worsening in the management of patients with hemoglobinopathies. MDPI 2023-09-11 /pmc/articles/PMC10514849/ /pubmed/37736989 http://dx.doi.org/10.3390/tomography9050136 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Meloni, Antonella
Pistoia, Laura
Lupi, Amalia
Righi, Riccardo
Vallone, Antonino
Missere, Massimiliano
Renne, Stefania
Fina, Priscilla
Riva, Ada
Gamberini, Maria Rita
Cecinati, Valerio
Sorrentino, Francesco
Rosso, Rosamaria
Messina, Giuseppe
Ricchi, Paolo
Positano, Vincenzo
Mavrogeni, Sophie
Quaia, Emilio
Cademartiri, Filippo
Pepe, Alessia
Impact of the COVID-19 Pandemic on Iron Overload Assessment by MRI in Patients with Hemoglobinopathies: The E-MIOT Network Experience
title Impact of the COVID-19 Pandemic on Iron Overload Assessment by MRI in Patients with Hemoglobinopathies: The E-MIOT Network Experience
title_full Impact of the COVID-19 Pandemic on Iron Overload Assessment by MRI in Patients with Hemoglobinopathies: The E-MIOT Network Experience
title_fullStr Impact of the COVID-19 Pandemic on Iron Overload Assessment by MRI in Patients with Hemoglobinopathies: The E-MIOT Network Experience
title_full_unstemmed Impact of the COVID-19 Pandemic on Iron Overload Assessment by MRI in Patients with Hemoglobinopathies: The E-MIOT Network Experience
title_short Impact of the COVID-19 Pandemic on Iron Overload Assessment by MRI in Patients with Hemoglobinopathies: The E-MIOT Network Experience
title_sort impact of the covid-19 pandemic on iron overload assessment by mri in patients with hemoglobinopathies: the e-miot network experience
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10514849/
https://www.ncbi.nlm.nih.gov/pubmed/37736989
http://dx.doi.org/10.3390/tomography9050136
work_keys_str_mv AT meloniantonella impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT pistoialaura impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT lupiamalia impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT righiriccardo impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT valloneantonino impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT misseremassimiliano impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT rennestefania impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT finapriscilla impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT rivaada impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT gamberinimariarita impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT cecinativalerio impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT sorrentinofrancesco impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT rossorosamaria impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT messinagiuseppe impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT ricchipaolo impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT positanovincenzo impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT mavrogenisophie impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT quaiaemilio impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT cademartirifilippo impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience
AT pepealessia impactofthecovid19pandemiconironoverloadassessmentbymriinpatientswithhemoglobinopathiestheemiotnetworkexperience