Cargando…
Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications
This paper focuses on the development of a novel electrode based on boron-doped diamond nanosheet full-volume-enriched screen-printed carbon electrodes (BDDPE) for use as an impedimetric biosensor. Impedimetric biosensors offer high sensitivity and selectivity for virus detection, but their use as p...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Vienna
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10516795/ https://www.ncbi.nlm.nih.gov/pubmed/37736868 http://dx.doi.org/10.1007/s00604-023-05991-w |
_version_ | 1785109203326599168 |
---|---|
author | Ficek, Mateusz Cieślik, Mateusz Janik, Monika Brodowski, Mateusz Sawczak, Mirosław Bogdanowicz, Robert Ryl, Jacek |
author_facet | Ficek, Mateusz Cieślik, Mateusz Janik, Monika Brodowski, Mateusz Sawczak, Mirosław Bogdanowicz, Robert Ryl, Jacek |
author_sort | Ficek, Mateusz |
collection | PubMed |
description | This paper focuses on the development of a novel electrode based on boron-doped diamond nanosheet full-volume-enriched screen-printed carbon electrodes (BDDPE) for use as an impedimetric biosensor. Impedimetric biosensors offer high sensitivity and selectivity for virus detection, but their use as point-of-care devices is limited by the complexity of nanomaterials’ architecture and the receptor immobilisation procedures. The study presents a two-step modification process involving the electroreduction of diazonium salt at the BDDPE and the immobilisation of antibodies using zero-length cross-linkers for a selective impedimetric biosensor of Haemophilus influenzae (Hi). The incorporation of diamond nanosheets into BDDPE leads to enhanced charge transfer and electrochemical behaviour, demonstrating greatly improved electrochemically active surface area compared with unmodified screen-printed electrodes (by 44% and 10% on average for [Ru(NH(3))(6)]Cl(2) and K(3)[Fe(CN)(6)], respectively). The presented sensing system shows high specificity towards protein D in Hi bacteria, as confirmed by negative controls against potential interference from other pathogens, with an estimated tolerance limit for interference under 12%. The Hi limit of detection by electrochemical impedance spectroscopy was 1 CFU/mL (measured at − 0.13 V vs BDDPE pseudo-reference), which was achieved in under 10 min, including 5 min sample incubation in the presence of the analyte. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-023-05991-w. |
format | Online Article Text |
id | pubmed-10516795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Vienna |
record_format | MEDLINE/PubMed |
spelling | pubmed-105167952023-09-24 Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications Ficek, Mateusz Cieślik, Mateusz Janik, Monika Brodowski, Mateusz Sawczak, Mirosław Bogdanowicz, Robert Ryl, Jacek Mikrochim Acta Original Paper This paper focuses on the development of a novel electrode based on boron-doped diamond nanosheet full-volume-enriched screen-printed carbon electrodes (BDDPE) for use as an impedimetric biosensor. Impedimetric biosensors offer high sensitivity and selectivity for virus detection, but their use as point-of-care devices is limited by the complexity of nanomaterials’ architecture and the receptor immobilisation procedures. The study presents a two-step modification process involving the electroreduction of diazonium salt at the BDDPE and the immobilisation of antibodies using zero-length cross-linkers for a selective impedimetric biosensor of Haemophilus influenzae (Hi). The incorporation of diamond nanosheets into BDDPE leads to enhanced charge transfer and electrochemical behaviour, demonstrating greatly improved electrochemically active surface area compared with unmodified screen-printed electrodes (by 44% and 10% on average for [Ru(NH(3))(6)]Cl(2) and K(3)[Fe(CN)(6)], respectively). The presented sensing system shows high specificity towards protein D in Hi bacteria, as confirmed by negative controls against potential interference from other pathogens, with an estimated tolerance limit for interference under 12%. The Hi limit of detection by electrochemical impedance spectroscopy was 1 CFU/mL (measured at − 0.13 V vs BDDPE pseudo-reference), which was achieved in under 10 min, including 5 min sample incubation in the presence of the analyte. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-023-05991-w. Springer Vienna 2023-09-22 2023 /pmc/articles/PMC10516795/ /pubmed/37736868 http://dx.doi.org/10.1007/s00604-023-05991-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Ficek, Mateusz Cieślik, Mateusz Janik, Monika Brodowski, Mateusz Sawczak, Mirosław Bogdanowicz, Robert Ryl, Jacek Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications |
title | Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications |
title_full | Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications |
title_fullStr | Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications |
title_full_unstemmed | Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications |
title_short | Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications |
title_sort | boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10516795/ https://www.ncbi.nlm.nih.gov/pubmed/37736868 http://dx.doi.org/10.1007/s00604-023-05991-w |
work_keys_str_mv | AT ficekmateusz borondopeddiamondnanosheetvolumeenrichedscreenprintedcarbonelectrodesaplatformforelectroanalyticalandimpedimetricbiosensorapplications AT cieslikmateusz borondopeddiamondnanosheetvolumeenrichedscreenprintedcarbonelectrodesaplatformforelectroanalyticalandimpedimetricbiosensorapplications AT janikmonika borondopeddiamondnanosheetvolumeenrichedscreenprintedcarbonelectrodesaplatformforelectroanalyticalandimpedimetricbiosensorapplications AT brodowskimateusz borondopeddiamondnanosheetvolumeenrichedscreenprintedcarbonelectrodesaplatformforelectroanalyticalandimpedimetricbiosensorapplications AT sawczakmirosław borondopeddiamondnanosheetvolumeenrichedscreenprintedcarbonelectrodesaplatformforelectroanalyticalandimpedimetricbiosensorapplications AT bogdanowiczrobert borondopeddiamondnanosheetvolumeenrichedscreenprintedcarbonelectrodesaplatformforelectroanalyticalandimpedimetricbiosensorapplications AT ryljacek borondopeddiamondnanosheetvolumeenrichedscreenprintedcarbonelectrodesaplatformforelectroanalyticalandimpedimetricbiosensorapplications |