Cargando…

Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty

BACKGROUND: Noise has been reported to occur with relatively high frequency after conventional total knee arthroplasty (C-TKA), and this may impact the incidence of patient satisfaction and function. The purpose of this study was to compare the rate of patient-reported prosthetic noise generation af...

Descripción completa

Detalles Bibliográficos
Autores principales: Cozzarelli, Nicholas F., Khan, Irfan A., Imam, Nareena, Klein, Gregg R., Levine, Harlan, Seidenstein, Ari, Zaid, Musa B., Lonner, Jess H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10518686/
https://www.ncbi.nlm.nih.gov/pubmed/37753221
http://dx.doi.org/10.1016/j.artd.2023.101216
_version_ 1785109570291499008
author Cozzarelli, Nicholas F.
Khan, Irfan A.
Imam, Nareena
Klein, Gregg R.
Levine, Harlan
Seidenstein, Ari
Zaid, Musa B.
Lonner, Jess H.
author_facet Cozzarelli, Nicholas F.
Khan, Irfan A.
Imam, Nareena
Klein, Gregg R.
Levine, Harlan
Seidenstein, Ari
Zaid, Musa B.
Lonner, Jess H.
author_sort Cozzarelli, Nicholas F.
collection PubMed
description BACKGROUND: Noise has been reported to occur with relatively high frequency after conventional total knee arthroplasty (C-TKA), and this may impact the incidence of patient satisfaction and function. The purpose of this study was to compare the rate of patient-reported prosthetic noise generation after robotically-assisted TKA (RA-TKA) and C-TKA. METHODS: A retrospective study was conducted of unilateral primary RA-TKAs and C-TKAs performed between 2018 and 2021. Patients completed a survey consisting of 4 Likert scale questions related to prosthetic noise generation and Knee Injury and Osteoarthritis Score Joint Replacement and Forgotten Joint Score were assessed prospectively preoperatively and at a minimum of 1-year of clinical follow-up. Statistical analysis was done utilizing T-tests and chi-square tests, with statistical significance defined as a P-value < .05. RESULTS: One hundred sixty-two RA-TKAs and 320 C-TKAs with similar baseline characteristics and functions were included. There were no significant differences in hearing or feeling grinding, popping, clicking, or clunking (40.7% vs 38.1%; P = .647) between groups. Most RA-TKAs and C-TKAs were not dissatisfied regarding noise generation (70.4% vs 73.1%; P = .596). In both cohorts, patients who reported noise generation had lower average Forgotten Joint Scores (45.5 vs 66.1; P < .001) and lower postoperative Knee Injury and Osteoarthritis Score Joint Replacement scores (72.0 vs 81.4; P < .001) than those who did not experience noise generation. CONCLUSIONS: While RA-TKA may facilitate soft tissue balancing, there were no differences in prosthetic noise generation between RA-TKA and C-TKA. However, those who experience implant-generated noise have lower functional outcome scores.
format Online
Article
Text
id pubmed-10518686
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105186862023-09-26 Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty Cozzarelli, Nicholas F. Khan, Irfan A. Imam, Nareena Klein, Gregg R. Levine, Harlan Seidenstein, Ari Zaid, Musa B. Lonner, Jess H. Arthroplast Today Original Research BACKGROUND: Noise has been reported to occur with relatively high frequency after conventional total knee arthroplasty (C-TKA), and this may impact the incidence of patient satisfaction and function. The purpose of this study was to compare the rate of patient-reported prosthetic noise generation after robotically-assisted TKA (RA-TKA) and C-TKA. METHODS: A retrospective study was conducted of unilateral primary RA-TKAs and C-TKAs performed between 2018 and 2021. Patients completed a survey consisting of 4 Likert scale questions related to prosthetic noise generation and Knee Injury and Osteoarthritis Score Joint Replacement and Forgotten Joint Score were assessed prospectively preoperatively and at a minimum of 1-year of clinical follow-up. Statistical analysis was done utilizing T-tests and chi-square tests, with statistical significance defined as a P-value < .05. RESULTS: One hundred sixty-two RA-TKAs and 320 C-TKAs with similar baseline characteristics and functions were included. There were no significant differences in hearing or feeling grinding, popping, clicking, or clunking (40.7% vs 38.1%; P = .647) between groups. Most RA-TKAs and C-TKAs were not dissatisfied regarding noise generation (70.4% vs 73.1%; P = .596). In both cohorts, patients who reported noise generation had lower average Forgotten Joint Scores (45.5 vs 66.1; P < .001) and lower postoperative Knee Injury and Osteoarthritis Score Joint Replacement scores (72.0 vs 81.4; P < .001) than those who did not experience noise generation. CONCLUSIONS: While RA-TKA may facilitate soft tissue balancing, there were no differences in prosthetic noise generation between RA-TKA and C-TKA. However, those who experience implant-generated noise have lower functional outcome scores. Elsevier 2023-09-16 /pmc/articles/PMC10518686/ /pubmed/37753221 http://dx.doi.org/10.1016/j.artd.2023.101216 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Cozzarelli, Nicholas F.
Khan, Irfan A.
Imam, Nareena
Klein, Gregg R.
Levine, Harlan
Seidenstein, Ari
Zaid, Musa B.
Lonner, Jess H.
Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty
title Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty
title_full Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty
title_fullStr Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty
title_full_unstemmed Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty
title_short Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty
title_sort robotic-assisted total knee arthroplasty has similar rates of prosthetic noise generation as conventional total knee arthroplasty
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10518686/
https://www.ncbi.nlm.nih.gov/pubmed/37753221
http://dx.doi.org/10.1016/j.artd.2023.101216
work_keys_str_mv AT cozzarellinicholasf roboticassistedtotalkneearthroplastyhassimilarratesofprostheticnoisegenerationasconventionaltotalkneearthroplasty
AT khanirfana roboticassistedtotalkneearthroplastyhassimilarratesofprostheticnoisegenerationasconventionaltotalkneearthroplasty
AT imamnareena roboticassistedtotalkneearthroplastyhassimilarratesofprostheticnoisegenerationasconventionaltotalkneearthroplasty
AT kleingreggr roboticassistedtotalkneearthroplastyhassimilarratesofprostheticnoisegenerationasconventionaltotalkneearthroplasty
AT levineharlan roboticassistedtotalkneearthroplastyhassimilarratesofprostheticnoisegenerationasconventionaltotalkneearthroplasty
AT seidensteinari roboticassistedtotalkneearthroplastyhassimilarratesofprostheticnoisegenerationasconventionaltotalkneearthroplasty
AT zaidmusab roboticassistedtotalkneearthroplastyhassimilarratesofprostheticnoisegenerationasconventionaltotalkneearthroplasty
AT lonnerjessh roboticassistedtotalkneearthroplastyhassimilarratesofprostheticnoisegenerationasconventionaltotalkneearthroplasty