Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements
PURPOSE: To compare the reliability and agreement of axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) measurements obtained with optical biometry based on swept-source optical coherence tomography (IOLMaster 700; Carl Zeiss, Germany) and an ultrasound biometry device (Nidek;...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10518768/ https://www.ncbi.nlm.nih.gov/pubmed/37567838 http://dx.doi.org/10.1016/j.optom.2023.05.001 |
_version_ | 1785109588603830272 |
---|---|
author | Khorrami-Nejad, Masoud Khodair, Ahmed Mohammed Khodaparast, Mehdi Babapour Mofrad, Farshid Dehghanian Nasrabadi, Farzaneh |
author_facet | Khorrami-Nejad, Masoud Khodair, Ahmed Mohammed Khodaparast, Mehdi Babapour Mofrad, Farshid Dehghanian Nasrabadi, Farzaneh |
author_sort | Khorrami-Nejad, Masoud |
collection | PubMed |
description | PURPOSE: To compare the reliability and agreement of axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) measurements obtained with optical biometry based on swept-source optical coherence tomography (IOLMaster 700; Carl Zeiss, Germany) and an ultrasound biometry device (Nidek; US-4000 Echoscan, Japan) in different qualities of AL measurement. METHODS: A total of 239 consecutive eyes of 239 cataract surgery candidates with a mean age of 56 ± 14 years were included. The quality measurements were grouped according to the quartiles of SD of the measured AL by IOLMaster 700. The first and fourth quartile's SD are defined as high and low-quality measurement, respectively, and the second and third quartiles’ SD is defined as moderate-quality. RESULTS: The reliability of AL and ACD between the two devices in all patients and in different quality measurement groups was excellent with highly statistically significant (AL: all ICC=0.999 and P<0.001, ACD: all ICC>0.920 and P<0.001). AL and ACD in all quality measurements showed a very strong correlation between devices with highly statistically significant. However, there was poor (ICC=0.305), moderate (ICC=0.742), and good (ICC=0.843) reliability in measuring LT in low-, moderate-, and high-quality measurements, respectively. LT showed a very strong correlation (r = 0.854) with highly statistically significant (P<0.001) between devices only in patients with high-quality measurements. CONCLUSIONS: AL and ACD of the IOLMaster700 had outstanding agreements with the US-4000 ultrasound in different quality measurements of AL and can be used interchangeably. But LT should be used interchangeably cautiously only in the high-quality measurements group. |
format | Online Article Text |
id | pubmed-10518768 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-105187682023-09-26 Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements Khorrami-Nejad, Masoud Khodair, Ahmed Mohammed Khodaparast, Mehdi Babapour Mofrad, Farshid Dehghanian Nasrabadi, Farzaneh J Optom Original Article PURPOSE: To compare the reliability and agreement of axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) measurements obtained with optical biometry based on swept-source optical coherence tomography (IOLMaster 700; Carl Zeiss, Germany) and an ultrasound biometry device (Nidek; US-4000 Echoscan, Japan) in different qualities of AL measurement. METHODS: A total of 239 consecutive eyes of 239 cataract surgery candidates with a mean age of 56 ± 14 years were included. The quality measurements were grouped according to the quartiles of SD of the measured AL by IOLMaster 700. The first and fourth quartile's SD are defined as high and low-quality measurement, respectively, and the second and third quartiles’ SD is defined as moderate-quality. RESULTS: The reliability of AL and ACD between the two devices in all patients and in different quality measurement groups was excellent with highly statistically significant (AL: all ICC=0.999 and P<0.001, ACD: all ICC>0.920 and P<0.001). AL and ACD in all quality measurements showed a very strong correlation between devices with highly statistically significant. However, there was poor (ICC=0.305), moderate (ICC=0.742), and good (ICC=0.843) reliability in measuring LT in low-, moderate-, and high-quality measurements, respectively. LT showed a very strong correlation (r = 0.854) with highly statistically significant (P<0.001) between devices only in patients with high-quality measurements. CONCLUSIONS: AL and ACD of the IOLMaster700 had outstanding agreements with the US-4000 ultrasound in different quality measurements of AL and can be used interchangeably. But LT should be used interchangeably cautiously only in the high-quality measurements group. Elsevier 2023 2023-08-09 /pmc/articles/PMC10518768/ /pubmed/37567838 http://dx.doi.org/10.1016/j.optom.2023.05.001 Text en © 2023 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Article Khorrami-Nejad, Masoud Khodair, Ahmed Mohammed Khodaparast, Mehdi Babapour Mofrad, Farshid Dehghanian Nasrabadi, Farzaneh Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements |
title | Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements |
title_full | Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements |
title_fullStr | Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements |
title_full_unstemmed | Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements |
title_short | Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements |
title_sort | comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10518768/ https://www.ncbi.nlm.nih.gov/pubmed/37567838 http://dx.doi.org/10.1016/j.optom.2023.05.001 |
work_keys_str_mv | AT khorraminejadmasoud comparisonoftheocularultrasonicandopticalbiometrydevicesinthedifferentqualitymeasurements AT khodairahmedmohammed comparisonoftheocularultrasonicandopticalbiometrydevicesinthedifferentqualitymeasurements AT khodaparastmehdi comparisonoftheocularultrasonicandopticalbiometrydevicesinthedifferentqualitymeasurements AT babapourmofradfarshid comparisonoftheocularultrasonicandopticalbiometrydevicesinthedifferentqualitymeasurements AT dehghaniannasrabadifarzaneh comparisonoftheocularultrasonicandopticalbiometrydevicesinthedifferentqualitymeasurements |