Cargando…

The modified Borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test

BACKGROUND: The 6-min walk test (6MWT) is widely used to assess exercise capacity across chronic health conditions, but is currently not useful to assess symptoms, as the scores do not account for the 6-min walk distance (6MWD). We aimed to 1) develop normative reference equations for breathlessness...

Descripción completa

Detalles Bibliográficos
Autores principales: Ekström, Magnus, Li, Pei Zhi, Lewthwaite, Hayley, Bourbeau, Jean, Tan, Wan C., Jensen, Dennis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Respiratory Society 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10518869/
https://www.ncbi.nlm.nih.gov/pubmed/37753276
http://dx.doi.org/10.1183/23120541.00281-2023
_version_ 1785109609228271616
author Ekström, Magnus
Li, Pei Zhi
Lewthwaite, Hayley
Bourbeau, Jean
Tan, Wan C.
Jensen, Dennis
author_facet Ekström, Magnus
Li, Pei Zhi
Lewthwaite, Hayley
Bourbeau, Jean
Tan, Wan C.
Jensen, Dennis
author_sort Ekström, Magnus
collection PubMed
description BACKGROUND: The 6-min walk test (6MWT) is widely used to assess exercise capacity across chronic health conditions, but is currently not useful to assess symptoms, as the scores do not account for the 6-min walk distance (6MWD). We aimed to 1) develop normative reference equations for breathlessness and leg discomfort intensity expressed as modified Borg (mBorg)/6MWD ratios; and 2) validate the equations in people with COPD. METHODS: Analysis of people aged ≥40 years who performed two 6MWTs (on a 20-m course) in the Canadian Cohort Obstructive Lung Disease (CanCOLD) study: a healthy cohort (n=291; mean±sd age 67.5±9.4 years; 54% male) with normal 6MWD and lung function, and a COPD cohort (n=156; age 66.2±9.0 years; 56% male; forced expiratory volume in 1 s (FEV(1))/forced vital capacity 56.6±8.2%; FEV(1) 74.4±18.6% pred). The mBorg score was calculated as the Borg 0–10 category ratio intensity rating of breathlessness or leg discomfort recorded at the end of the 6MWT +1 (range 1–11), to avoid zeros and yield ratios proportional to the symptom score and 6MWD−1. RESULTS: Using data from the healthy cohort, sex-specific normative reference equations for breathlessness and leg discomfort mBorg/6MWD ratios were developed using multivariable linear regression, accounting for age, and body mass or body mass index. In the COPD cohort, abnormal breathlessness and leg discomfort (mBorg/6MWD>upper limit of normal) showed strong concurrent validity with worse airflow limitation, Medical Research Council breathlessness and COPD Assessment Test scores. CONCLUSION: Normative references for the mBorg/6MWD ratio are presented to assess breathlessness and leg discomfort responses to the 6MWT in COPD.
format Online
Article
Text
id pubmed-10518869
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher European Respiratory Society
record_format MEDLINE/PubMed
spelling pubmed-105188692023-09-26 The modified Borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test Ekström, Magnus Li, Pei Zhi Lewthwaite, Hayley Bourbeau, Jean Tan, Wan C. Jensen, Dennis ERJ Open Res Original Research Articles BACKGROUND: The 6-min walk test (6MWT) is widely used to assess exercise capacity across chronic health conditions, but is currently not useful to assess symptoms, as the scores do not account for the 6-min walk distance (6MWD). We aimed to 1) develop normative reference equations for breathlessness and leg discomfort intensity expressed as modified Borg (mBorg)/6MWD ratios; and 2) validate the equations in people with COPD. METHODS: Analysis of people aged ≥40 years who performed two 6MWTs (on a 20-m course) in the Canadian Cohort Obstructive Lung Disease (CanCOLD) study: a healthy cohort (n=291; mean±sd age 67.5±9.4 years; 54% male) with normal 6MWD and lung function, and a COPD cohort (n=156; age 66.2±9.0 years; 56% male; forced expiratory volume in 1 s (FEV(1))/forced vital capacity 56.6±8.2%; FEV(1) 74.4±18.6% pred). The mBorg score was calculated as the Borg 0–10 category ratio intensity rating of breathlessness or leg discomfort recorded at the end of the 6MWT +1 (range 1–11), to avoid zeros and yield ratios proportional to the symptom score and 6MWD−1. RESULTS: Using data from the healthy cohort, sex-specific normative reference equations for breathlessness and leg discomfort mBorg/6MWD ratios were developed using multivariable linear regression, accounting for age, and body mass or body mass index. In the COPD cohort, abnormal breathlessness and leg discomfort (mBorg/6MWD>upper limit of normal) showed strong concurrent validity with worse airflow limitation, Medical Research Council breathlessness and COPD Assessment Test scores. CONCLUSION: Normative references for the mBorg/6MWD ratio are presented to assess breathlessness and leg discomfort responses to the 6MWT in COPD. European Respiratory Society 2023-09-25 /pmc/articles/PMC10518869/ /pubmed/37753276 http://dx.doi.org/10.1183/23120541.00281-2023 Text en Copyright ©The authors 2023 https://creativecommons.org/licenses/by-nc/4.0/This version is distributed under the terms of the Creative Commons Attribution Non-Commercial Licence 4.0. For commercial reproduction rights and permissions contact permissions@ersnet.org (mailto:permissions@ersnet.org)
spellingShingle Original Research Articles
Ekström, Magnus
Li, Pei Zhi
Lewthwaite, Hayley
Bourbeau, Jean
Tan, Wan C.
Jensen, Dennis
The modified Borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test
title The modified Borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test
title_full The modified Borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test
title_fullStr The modified Borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test
title_full_unstemmed The modified Borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test
title_short The modified Borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test
title_sort modified borg/6-min walk distance ratio: a method to assess exertional breathlessness and leg discomfort using the 6-min walk test
topic Original Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10518869/
https://www.ncbi.nlm.nih.gov/pubmed/37753276
http://dx.doi.org/10.1183/23120541.00281-2023
work_keys_str_mv AT ekstrommagnus themodifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT lipeizhi themodifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT lewthwaitehayley themodifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT bourbeaujean themodifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT tanwanc themodifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT jensendennis themodifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT ekstrommagnus modifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT lipeizhi modifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT lewthwaitehayley modifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT bourbeaujean modifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT tanwanc modifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest
AT jensendennis modifiedborg6minwalkdistanceratioamethodtoassessexertionalbreathlessnessandlegdiscomfortusingthe6minwalktest