Cargando…

Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens

PURPOSE: To identify risk factors of ocular anterior segment measurement error by the IOLMaster 700 in eyes implanted with an implantable Collamer lens (ICL). METHODS: In total, 152 patients with clear lens (152 eyes, group 1) and another 32 cataract patients (57 eyes, group 2) who underwent ICL imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jiaqing, Chen, Fei, Han, Xiaotong, Qiu, Xiaozhang, Liu, Zhenzhen, Chen, Xiaoyun, Jin, Guangming, Qu, Bo, Yao, Huan, Ye, Yiming, Yu, Keming, Tan, Xuhua, Luo, Lixia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10519433/
https://www.ncbi.nlm.nih.gov/pubmed/37738056
http://dx.doi.org/10.1167/tvst.12.9.16
_version_ 1785109696157319168
author Zhang, Jiaqing
Chen, Fei
Han, Xiaotong
Qiu, Xiaozhang
Liu, Zhenzhen
Chen, Xiaoyun
Jin, Guangming
Qu, Bo
Yao, Huan
Ye, Yiming
Yu, Keming
Tan, Xuhua
Luo, Lixia
author_facet Zhang, Jiaqing
Chen, Fei
Han, Xiaotong
Qiu, Xiaozhang
Liu, Zhenzhen
Chen, Xiaoyun
Jin, Guangming
Qu, Bo
Yao, Huan
Ye, Yiming
Yu, Keming
Tan, Xuhua
Luo, Lixia
author_sort Zhang, Jiaqing
collection PubMed
description PURPOSE: To identify risk factors of ocular anterior segment measurement error by the IOLMaster 700 in eyes implanted with an implantable Collamer lens (ICL). METHODS: In total, 152 patients with clear lens (152 eyes, group 1) and another 32 cataract patients (57 eyes, group 2) who underwent ICL implantation were included, and the presence of measurement error by the IOLMaster 700 was determined based on B-scan images. The risk factors for measurement error were evaluated by logistic regression, and the optimal threshold was determined using receiver operating characteristic analysis. RESULTS: The ICL was misidentified as the anterior surface of the crystalline lens in 51.97% of eyes (79/152) in group 1 and 80.70% of eyes (46/57) in group 2. For every 100-µm decrease in the vault height, a 3.57- and 5.78-fold increase in the risk of measurement error was observed in group 1 and group 2, respectively. We identified an optimal threshold of the vault height at 389.47 µm for predicting biometric measurement error in eyes implanted with ICL, which showed an area under the curve of 0.93 (95% confidence interval, 0.90–0.97), a sensitivity of 0.87, and a specificity of 0.86. CONCLUSIONS: Patients with ICL implantation, particularly those with a vault height less than 389.47 µm, are at a greater risk of anterior segment biometric measurement error by the IOLMaster 700. TRANSLATIONAL RELEVANCE: The threshold of vault height can help to identify high-risk patients and further optimize biometric measurement.
format Online
Article
Text
id pubmed-10519433
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-105194332023-09-26 Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens Zhang, Jiaqing Chen, Fei Han, Xiaotong Qiu, Xiaozhang Liu, Zhenzhen Chen, Xiaoyun Jin, Guangming Qu, Bo Yao, Huan Ye, Yiming Yu, Keming Tan, Xuhua Luo, Lixia Transl Vis Sci Technol Lens PURPOSE: To identify risk factors of ocular anterior segment measurement error by the IOLMaster 700 in eyes implanted with an implantable Collamer lens (ICL). METHODS: In total, 152 patients with clear lens (152 eyes, group 1) and another 32 cataract patients (57 eyes, group 2) who underwent ICL implantation were included, and the presence of measurement error by the IOLMaster 700 was determined based on B-scan images. The risk factors for measurement error were evaluated by logistic regression, and the optimal threshold was determined using receiver operating characteristic analysis. RESULTS: The ICL was misidentified as the anterior surface of the crystalline lens in 51.97% of eyes (79/152) in group 1 and 80.70% of eyes (46/57) in group 2. For every 100-µm decrease in the vault height, a 3.57- and 5.78-fold increase in the risk of measurement error was observed in group 1 and group 2, respectively. We identified an optimal threshold of the vault height at 389.47 µm for predicting biometric measurement error in eyes implanted with ICL, which showed an area under the curve of 0.93 (95% confidence interval, 0.90–0.97), a sensitivity of 0.87, and a specificity of 0.86. CONCLUSIONS: Patients with ICL implantation, particularly those with a vault height less than 389.47 µm, are at a greater risk of anterior segment biometric measurement error by the IOLMaster 700. TRANSLATIONAL RELEVANCE: The threshold of vault height can help to identify high-risk patients and further optimize biometric measurement. The Association for Research in Vision and Ophthalmology 2023-09-22 /pmc/articles/PMC10519433/ /pubmed/37738056 http://dx.doi.org/10.1167/tvst.12.9.16 Text en Copyright 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Lens
Zhang, Jiaqing
Chen, Fei
Han, Xiaotong
Qiu, Xiaozhang
Liu, Zhenzhen
Chen, Xiaoyun
Jin, Guangming
Qu, Bo
Yao, Huan
Ye, Yiming
Yu, Keming
Tan, Xuhua
Luo, Lixia
Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens
title Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens
title_full Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens
title_fullStr Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens
title_full_unstemmed Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens
title_short Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens
title_sort vault height is a key predictive factor for anterior segment measurement error by iolmaster 700 in eyes with phakic intraocular lens
topic Lens
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10519433/
https://www.ncbi.nlm.nih.gov/pubmed/37738056
http://dx.doi.org/10.1167/tvst.12.9.16
work_keys_str_mv AT zhangjiaqing vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT chenfei vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT hanxiaotong vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT qiuxiaozhang vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT liuzhenzhen vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT chenxiaoyun vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT jinguangming vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT qubo vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT yaohuan vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT yeyiming vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT yukeming vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT tanxuhua vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens
AT luolixia vaultheightisakeypredictivefactorforanteriorsegmentmeasurementerrorbyiolmaster700ineyeswithphakicintraocularlens