Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study

BACKGROUND: It is common for dental technicians to adjust the proximal surface of adjacent teeth on casts when fabricating single crowns. However, whether the accuracy of the proximal contact is affected if this step is eliminated is unclear. OBJECTIVE: To evaluate the accuracy of the proximal conta...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Daniel S., Lau, Le Na, Kim, Jong-Woong, Yeo, In-Sung Luke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520794/
https://www.ncbi.nlm.nih.gov/pubmed/37767497
http://dx.doi.org/10.1016/j.heliyon.2023.e20403
_version_ 1785110000644915200
author Kim, Daniel S.
Lau, Le Na
Kim, Jong-Woong
Yeo, In-Sung Luke
author_facet Kim, Daniel S.
Lau, Le Na
Kim, Jong-Woong
Yeo, In-Sung Luke
author_sort Kim, Daniel S.
collection PubMed
description BACKGROUND: It is common for dental technicians to adjust the proximal surface of adjacent teeth on casts when fabricating single crowns. However, whether the accuracy of the proximal contact is affected if this step is eliminated is unclear. OBJECTIVE: To evaluate the accuracy of the proximal contact of single crowns for mandibular first molars fabricated from four different restorative materials, without adjustment of the proximal surface of the adjacent teeth by the laboratory/dental technician. METHODS: This study was in vitro; all the clinical procedures were conducted on a dentoform. The mandibular first molar tooth on the dentoform was prepared using diamond burs and a high speed handpiece. Twenty single crowns were fabricated, five for each group (monolithic zirconia, lithium disilicate, metal ceramic, and cast gold). No proximal surface adjacent to the definitive crowns was adjusted for tight contact in the dental laboratory. Both the qualitative analyses, using dental floss and shimstock, and the quantitative analyses, using a stereo microscope, were performed to evaluate the accuracy of the proximal contact of the restoration with the adjacent teeth. In the quantitative analysis, one-way analysis of variance was used to compare mean values at a significance level of 0.05. RESULTS: In quantitative analysis, the differences between the proximal contact tightness of the four groups was not statistically significant (P = 0.802 for mesial contacts, P = 0.354 for distal contacts). In qualitative analysis, in most crowns, dental floss passed through the contact with tight resistance and only one film of shimstock could be inserted between the adjacent teeth and the restoration. However, one specimen from the cast gold crown had open contact. CONCLUSIONS: Even without proximal surface adjustment of the adjacent teeth during the crown fabrication process, adequate proximal contact tightness between the restoration and adjacent teeth could be achieved.
format Online
Article
Text
id pubmed-10520794
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105207942023-09-27 Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study Kim, Daniel S. Lau, Le Na Kim, Jong-Woong Yeo, In-Sung Luke Heliyon Research Article BACKGROUND: It is common for dental technicians to adjust the proximal surface of adjacent teeth on casts when fabricating single crowns. However, whether the accuracy of the proximal contact is affected if this step is eliminated is unclear. OBJECTIVE: To evaluate the accuracy of the proximal contact of single crowns for mandibular first molars fabricated from four different restorative materials, without adjustment of the proximal surface of the adjacent teeth by the laboratory/dental technician. METHODS: This study was in vitro; all the clinical procedures were conducted on a dentoform. The mandibular first molar tooth on the dentoform was prepared using diamond burs and a high speed handpiece. Twenty single crowns were fabricated, five for each group (monolithic zirconia, lithium disilicate, metal ceramic, and cast gold). No proximal surface adjacent to the definitive crowns was adjusted for tight contact in the dental laboratory. Both the qualitative analyses, using dental floss and shimstock, and the quantitative analyses, using a stereo microscope, were performed to evaluate the accuracy of the proximal contact of the restoration with the adjacent teeth. In the quantitative analysis, one-way analysis of variance was used to compare mean values at a significance level of 0.05. RESULTS: In quantitative analysis, the differences between the proximal contact tightness of the four groups was not statistically significant (P = 0.802 for mesial contacts, P = 0.354 for distal contacts). In qualitative analysis, in most crowns, dental floss passed through the contact with tight resistance and only one film of shimstock could be inserted between the adjacent teeth and the restoration. However, one specimen from the cast gold crown had open contact. CONCLUSIONS: Even without proximal surface adjustment of the adjacent teeth during the crown fabrication process, adequate proximal contact tightness between the restoration and adjacent teeth could be achieved. Elsevier 2023-09-22 /pmc/articles/PMC10520794/ /pubmed/37767497 http://dx.doi.org/10.1016/j.heliyon.2023.e20403 Text en © 2023 The Authors. Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Kim, Daniel S.
Lau, Le Na
Kim, Jong-Woong
Yeo, In-Sung Luke
Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study
title Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study
title_full Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study
title_fullStr Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study
title_full_unstemmed Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study
title_short Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study
title_sort measurement of proximal contact of single crowns to assess interproximal relief: a pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520794/
https://www.ncbi.nlm.nih.gov/pubmed/37767497
http://dx.doi.org/10.1016/j.heliyon.2023.e20403
work_keys_str_mv AT kimdaniels measurementofproximalcontactofsinglecrownstoassessinterproximalreliefapilotstudy
AT laulena measurementofproximalcontactofsinglecrownstoassessinterproximalreliefapilotstudy
AT kimjongwoong measurementofproximalcontactofsinglecrownstoassessinterproximalreliefapilotstudy
AT yeoinsungluke measurementofproximalcontactofsinglecrownstoassessinterproximalreliefapilotstudy