SARS-Cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: A case report

INTRODUCTION AND IMPORTANCE: Complications using bioresorbable anchors in arthroscopic rotator cuff surgery include osteolysis, aseptic synovitis, and foreign body reaction. However, the precise triggering factors are unknown. CASE PRESENTATION: A healthy, 63-year-old male patient underwent rotator...

Descripción completa

Detalles Bibliográficos
Autores principales: Lante, Erica, Mahé, Grishma, Jany, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520802/
https://www.ncbi.nlm.nih.gov/pubmed/37742353
http://dx.doi.org/10.1016/j.ijscr.2023.108847
_version_ 1785110002541789184
author Lante, Erica
Mahé, Grishma
Jany, Richard
author_facet Lante, Erica
Mahé, Grishma
Jany, Richard
author_sort Lante, Erica
collection PubMed
description INTRODUCTION AND IMPORTANCE: Complications using bioresorbable anchors in arthroscopic rotator cuff surgery include osteolysis, aseptic synovitis, and foreign body reaction. However, the precise triggering factors are unknown. CASE PRESENTATION: A healthy, 63-year-old male patient underwent rotator cuff repair using 7PLGA/b-TCP anchors. Nine months after surgery he returned to the senior author because of right shoulder pain and stiffness, pain in the right hand, foot and leg, and presence of erythematous patches at the aforementioned joints following SARS-Cov-2 infection, as well as increasing in blood inflammatory markers. Magnetic Resonance Arthrography (Arthro-MRI) showed no rotator cuff tendons re-tear but intra-articular synovitis, subacromial bursitis and humeral osteitis. A diagnostic arthroscopy, intra-articular fluid collection, biopsy and joint lavage was performed to rule out a septic arthritis. Co-amoxicillin 2.2 g intravenous treatment was administered following samples. Histological analysis of synovial tissue showed fibrin-exudative synovitis, while humeral bone biopsy showed an anchor resorption reaction. All microbiological analysis showed sterile samples. Three months post-lavage follow-up physical examination showed painless, recovered mobility, while Arthro-MRI showed a significant post-refixation remodeling of the rotator cuff tendons and reduction in humeral head osteitis and synovitis. CLINICAL DISCUSSION: The abrupt onset of symptomatology and the close chronological link with SARS-Cov-2 infection suggests a causal relationship between clinical and radiological manifestations and the infection itself, with clinical and radiological manifestation being a viral host response reaction to SARS-Cov-2 infection. CONCLUSION: Shoulder pain, stiffness and humeral osteitis could be manifestations of a viral host response to SARS-Cov-2 infection.
format Online
Article
Text
id pubmed-10520802
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105208022023-09-27 SARS-Cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: A case report Lante, Erica Mahé, Grishma Jany, Richard Int J Surg Case Rep Case Report INTRODUCTION AND IMPORTANCE: Complications using bioresorbable anchors in arthroscopic rotator cuff surgery include osteolysis, aseptic synovitis, and foreign body reaction. However, the precise triggering factors are unknown. CASE PRESENTATION: A healthy, 63-year-old male patient underwent rotator cuff repair using 7PLGA/b-TCP anchors. Nine months after surgery he returned to the senior author because of right shoulder pain and stiffness, pain in the right hand, foot and leg, and presence of erythematous patches at the aforementioned joints following SARS-Cov-2 infection, as well as increasing in blood inflammatory markers. Magnetic Resonance Arthrography (Arthro-MRI) showed no rotator cuff tendons re-tear but intra-articular synovitis, subacromial bursitis and humeral osteitis. A diagnostic arthroscopy, intra-articular fluid collection, biopsy and joint lavage was performed to rule out a septic arthritis. Co-amoxicillin 2.2 g intravenous treatment was administered following samples. Histological analysis of synovial tissue showed fibrin-exudative synovitis, while humeral bone biopsy showed an anchor resorption reaction. All microbiological analysis showed sterile samples. Three months post-lavage follow-up physical examination showed painless, recovered mobility, while Arthro-MRI showed a significant post-refixation remodeling of the rotator cuff tendons and reduction in humeral head osteitis and synovitis. CLINICAL DISCUSSION: The abrupt onset of symptomatology and the close chronological link with SARS-Cov-2 infection suggests a causal relationship between clinical and radiological manifestations and the infection itself, with clinical and radiological manifestation being a viral host response reaction to SARS-Cov-2 infection. CONCLUSION: Shoulder pain, stiffness and humeral osteitis could be manifestations of a viral host response to SARS-Cov-2 infection. Elsevier 2023-09-17 /pmc/articles/PMC10520802/ /pubmed/37742353 http://dx.doi.org/10.1016/j.ijscr.2023.108847 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Lante, Erica
Mahé, Grishma
Jany, Richard
SARS-Cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: A case report
title SARS-Cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: A case report
title_full SARS-Cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: A case report
title_fullStr SARS-Cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: A case report
title_full_unstemmed SARS-Cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: A case report
title_short SARS-Cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: A case report
title_sort sars-cov-2 related shoulder pain and stiffness associated to humeral osteolysis after arthroscopic rotator cuff repair: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520802/
https://www.ncbi.nlm.nih.gov/pubmed/37742353
http://dx.doi.org/10.1016/j.ijscr.2023.108847
work_keys_str_mv AT lanteerica sarscov2relatedshoulderpainandstiffnessassociatedtohumeralosteolysisafterarthroscopicrotatorcuffrepairacasereport
AT mahegrishma sarscov2relatedshoulderpainandstiffnessassociatedtohumeralosteolysisafterarthroscopicrotatorcuffrepairacasereport
AT janyrichard sarscov2relatedshoulderpainandstiffnessassociatedtohumeralosteolysisafterarthroscopicrotatorcuffrepairacasereport