Cargando…
Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens
BACKGROUND: To evaluate the feasibility of creating flanges using an optic piercing technique with a 6 − 0 polypropylene monofilament for scleral fixation of dislocated one-piece diffractive multifocal intraocular lenses (IOLs). STUDY DESIGN: Experimental study and case series. SUBJECTS: Optical ben...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10521417/ https://www.ncbi.nlm.nih.gov/pubmed/37752479 http://dx.doi.org/10.1186/s12886-023-03133-7 |
_version_ | 1785110121117908992 |
---|---|
author | Eom, Youngsub Koh, Eunheh Yang, Seul Ki Kim, Soo Yi, Sungtae Jeon, Hyun Sun Kim, Seong-Jae So, Jason Song, Jong Suk Cooke, David L |
author_facet | Eom, Youngsub Koh, Eunheh Yang, Seul Ki Kim, Soo Yi, Sungtae Jeon, Hyun Sun Kim, Seong-Jae So, Jason Song, Jong Suk Cooke, David L |
author_sort | Eom, Youngsub |
collection | PubMed |
description | BACKGROUND: To evaluate the feasibility of creating flanges using an optic piercing technique with a 6 − 0 polypropylene monofilament for scleral fixation of dislocated one-piece diffractive multifocal intraocular lenses (IOLs). STUDY DESIGN: Experimental study and case series. SUBJECTS: Optical bench test and eyes with IOL dislocation. METHODS: Two separate 6 − 0 polypropylenes were penetrated twice at the opposite peripheral optic of the TECNIS Synergy IOL (Johnson & Johnson Vision). The root mean square of the modulation transfer function (MTF(RMS)), at between + 1.00 and − 4.00 D of defocus, was measured in the TECNIS Synergy IOL both with and without optic piercing in the optical bench study. This case series included three eyes from two patients who underwent scleral-fixation of multifocal IOLs using the four-flanged polypropylene optic piercing technique. The postoperative corrected distance visual acuity (CDVA) at 4 m, the uncorrected near visual acuity (UNVA) at 40 cm, and IOL centration were evaluated. RESULTS: The optical bench test showed no differences in MTF(RMS) values measured in the TECNIS Synergy IOL, either with or without optic piercing at all defocuses. In all three case series, the postoperative CDVA at 4 m was 20/20 and UNVA at 40 cm was J1. Postoperative anterior segment photographs showed good centration of IOLs in all cases. CONCLUSION: The four-flanged polypropylene optic piercing technique for multifocal IOL scleral fixation can provide excellent clinical outcomes and IOL stability after surgery without diminishing the performance of the multifocal IOLs. |
format | Online Article Text |
id | pubmed-10521417 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-105214172023-09-27 Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens Eom, Youngsub Koh, Eunheh Yang, Seul Ki Kim, Soo Yi, Sungtae Jeon, Hyun Sun Kim, Seong-Jae So, Jason Song, Jong Suk Cooke, David L BMC Ophthalmol Research BACKGROUND: To evaluate the feasibility of creating flanges using an optic piercing technique with a 6 − 0 polypropylene monofilament for scleral fixation of dislocated one-piece diffractive multifocal intraocular lenses (IOLs). STUDY DESIGN: Experimental study and case series. SUBJECTS: Optical bench test and eyes with IOL dislocation. METHODS: Two separate 6 − 0 polypropylenes were penetrated twice at the opposite peripheral optic of the TECNIS Synergy IOL (Johnson & Johnson Vision). The root mean square of the modulation transfer function (MTF(RMS)), at between + 1.00 and − 4.00 D of defocus, was measured in the TECNIS Synergy IOL both with and without optic piercing in the optical bench study. This case series included three eyes from two patients who underwent scleral-fixation of multifocal IOLs using the four-flanged polypropylene optic piercing technique. The postoperative corrected distance visual acuity (CDVA) at 4 m, the uncorrected near visual acuity (UNVA) at 40 cm, and IOL centration were evaluated. RESULTS: The optical bench test showed no differences in MTF(RMS) values measured in the TECNIS Synergy IOL, either with or without optic piercing at all defocuses. In all three case series, the postoperative CDVA at 4 m was 20/20 and UNVA at 40 cm was J1. Postoperative anterior segment photographs showed good centration of IOLs in all cases. CONCLUSION: The four-flanged polypropylene optic piercing technique for multifocal IOL scleral fixation can provide excellent clinical outcomes and IOL stability after surgery without diminishing the performance of the multifocal IOLs. BioMed Central 2023-09-26 /pmc/articles/PMC10521417/ /pubmed/37752479 http://dx.doi.org/10.1186/s12886-023-03133-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Eom, Youngsub Koh, Eunheh Yang, Seul Ki Kim, Soo Yi, Sungtae Jeon, Hyun Sun Kim, Seong-Jae So, Jason Song, Jong Suk Cooke, David L Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens |
title | Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens |
title_full | Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens |
title_fullStr | Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens |
title_full_unstemmed | Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens |
title_short | Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens |
title_sort | four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10521417/ https://www.ncbi.nlm.nih.gov/pubmed/37752479 http://dx.doi.org/10.1186/s12886-023-03133-7 |
work_keys_str_mv | AT eomyoungsub fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT koheunheh fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT yangseulki fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT kimsoo fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT yisungtae fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT jeonhyunsun fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT kimseongjae fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT sojason fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT songjongsuk fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens AT cookedavidl fourflangedpolypropyleneopticpiercingtechniqueforscleralfixationofmultifocalintraocularlens |