Cargando…

Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil

OBJECTIVE: This study aimed to determine the thyroid-stimulating hormone (TSH) reference interval (RI) and to assess the influence of the use of thyroid ultrasonography (TUS) on reference individual selection from a healthy adult population in Fortaleza, Brazil. SUBJECTS AND METHODS: This cross-sect...

Descripción completa

Detalles Bibliográficos
Autores principales: Gurgel, Maria Helane C, Ponte, Clarisse M. M., Fontes, Rosita, Rocha, Ítalo V., Batista, Lívia A. A., Sousa, Tamara C. S., Montenegro, Renan M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Endocrinologia e Metabologia 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10522077/
https://www.ncbi.nlm.nih.gov/pubmed/32725064
http://dx.doi.org/10.20945/2359-3997000000264
_version_ 1785110280145993728
author Gurgel, Maria Helane C
Ponte, Clarisse M. M.
Fontes, Rosita
Rocha, Ítalo V.
Batista, Lívia A. A.
Sousa, Tamara C. S.
Montenegro, Renan M.
author_facet Gurgel, Maria Helane C
Ponte, Clarisse M. M.
Fontes, Rosita
Rocha, Ítalo V.
Batista, Lívia A. A.
Sousa, Tamara C. S.
Montenegro, Renan M.
author_sort Gurgel, Maria Helane C
collection PubMed
description OBJECTIVE: This study aimed to determine the thyroid-stimulating hormone (TSH) reference interval (RI) and to assess the influence of the use of thyroid ultrasonography (TUS) on reference individual selection from a healthy adult population in Fortaleza, Brazil. SUBJECTS AND METHODS: This cross-sectional study recruited patients (N = 272; age = 18-50 years) with normal thyroid function (NTF) and placed them in three groups according to their test results: NTF (n = 272; all participants), TUS (n = 170; participants who underwent thyroid US), RI (n = 124; reference individuals with normal TSH levels). TSH, FT4, TT3, TgAb, and TPOAb concentrations were determined by electrochemiluminescence assay. TUS was performed using a 7-12 MHz multifrequency linear transducer by two radiologists. The 2.5(th) and 97.5(th) percentiles of the distribution curve corresponded to lower and upper TSH RI levels, respectively. RESULTS: The mean TSH level was 1.74 ± 0.96 mIU/L, and TSH range was 0.56-4.45 mIU/L. There was no difference in the TSH concentrations between men and women nor between the groups. TUS did not appear to be an essential tool for the reference group selection. CONCLUSION: The upper limit of TSH was comparable to the reference interval provided by the assay manufacturer (4.45 vs. 4.20 mIU/L) but the lower limit was not (0.56 vs. 0.27 mIU/L). This finding may have a clinical impact since these values may lead to the misdiagnosis of euthyroid patients with subclinical hyperthyroidism.
format Online
Article
Text
id pubmed-10522077
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Sociedade Brasileira de Endocrinologia e Metabologia
record_format MEDLINE/PubMed
spelling pubmed-105220772023-09-27 Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil Gurgel, Maria Helane C Ponte, Clarisse M. M. Fontes, Rosita Rocha, Ítalo V. Batista, Lívia A. A. Sousa, Tamara C. S. Montenegro, Renan M. Arch Endocrinol Metab Original Article OBJECTIVE: This study aimed to determine the thyroid-stimulating hormone (TSH) reference interval (RI) and to assess the influence of the use of thyroid ultrasonography (TUS) on reference individual selection from a healthy adult population in Fortaleza, Brazil. SUBJECTS AND METHODS: This cross-sectional study recruited patients (N = 272; age = 18-50 years) with normal thyroid function (NTF) and placed them in three groups according to their test results: NTF (n = 272; all participants), TUS (n = 170; participants who underwent thyroid US), RI (n = 124; reference individuals with normal TSH levels). TSH, FT4, TT3, TgAb, and TPOAb concentrations were determined by electrochemiluminescence assay. TUS was performed using a 7-12 MHz multifrequency linear transducer by two radiologists. The 2.5(th) and 97.5(th) percentiles of the distribution curve corresponded to lower and upper TSH RI levels, respectively. RESULTS: The mean TSH level was 1.74 ± 0.96 mIU/L, and TSH range was 0.56-4.45 mIU/L. There was no difference in the TSH concentrations between men and women nor between the groups. TUS did not appear to be an essential tool for the reference group selection. CONCLUSION: The upper limit of TSH was comparable to the reference interval provided by the assay manufacturer (4.45 vs. 4.20 mIU/L) but the lower limit was not (0.56 vs. 0.27 mIU/L). This finding may have a clinical impact since these values may lead to the misdiagnosis of euthyroid patients with subclinical hyperthyroidism. Sociedade Brasileira de Endocrinologia e Metabologia 2020-07-17 /pmc/articles/PMC10522077/ /pubmed/32725064 http://dx.doi.org/10.20945/2359-3997000000264 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Gurgel, Maria Helane C
Ponte, Clarisse M. M.
Fontes, Rosita
Rocha, Ítalo V.
Batista, Lívia A. A.
Sousa, Tamara C. S.
Montenegro, Renan M.
Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil
title Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil
title_full Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil
title_fullStr Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil
title_full_unstemmed Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil
title_short Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil
title_sort establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from fortaleza, brazil
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10522077/
https://www.ncbi.nlm.nih.gov/pubmed/32725064
http://dx.doi.org/10.20945/2359-3997000000264
work_keys_str_mv AT gurgelmariahelanec establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil
AT ponteclarissemm establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil
AT fontesrosita establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil
AT rochaitalov establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil
AT batistaliviaaa establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil
AT sousatamaracs establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil
AT montenegrorenanm establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil