Cargando…
Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil
OBJECTIVE: This study aimed to determine the thyroid-stimulating hormone (TSH) reference interval (RI) and to assess the influence of the use of thyroid ultrasonography (TUS) on reference individual selection from a healthy adult population in Fortaleza, Brazil. SUBJECTS AND METHODS: This cross-sect...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Endocrinologia e Metabologia
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10522077/ https://www.ncbi.nlm.nih.gov/pubmed/32725064 http://dx.doi.org/10.20945/2359-3997000000264 |
_version_ | 1785110280145993728 |
---|---|
author | Gurgel, Maria Helane C Ponte, Clarisse M. M. Fontes, Rosita Rocha, Ítalo V. Batista, Lívia A. A. Sousa, Tamara C. S. Montenegro, Renan M. |
author_facet | Gurgel, Maria Helane C Ponte, Clarisse M. M. Fontes, Rosita Rocha, Ítalo V. Batista, Lívia A. A. Sousa, Tamara C. S. Montenegro, Renan M. |
author_sort | Gurgel, Maria Helane C |
collection | PubMed |
description | OBJECTIVE: This study aimed to determine the thyroid-stimulating hormone (TSH) reference interval (RI) and to assess the influence of the use of thyroid ultrasonography (TUS) on reference individual selection from a healthy adult population in Fortaleza, Brazil. SUBJECTS AND METHODS: This cross-sectional study recruited patients (N = 272; age = 18-50 years) with normal thyroid function (NTF) and placed them in three groups according to their test results: NTF (n = 272; all participants), TUS (n = 170; participants who underwent thyroid US), RI (n = 124; reference individuals with normal TSH levels). TSH, FT4, TT3, TgAb, and TPOAb concentrations were determined by electrochemiluminescence assay. TUS was performed using a 7-12 MHz multifrequency linear transducer by two radiologists. The 2.5(th) and 97.5(th) percentiles of the distribution curve corresponded to lower and upper TSH RI levels, respectively. RESULTS: The mean TSH level was 1.74 ± 0.96 mIU/L, and TSH range was 0.56-4.45 mIU/L. There was no difference in the TSH concentrations between men and women nor between the groups. TUS did not appear to be an essential tool for the reference group selection. CONCLUSION: The upper limit of TSH was comparable to the reference interval provided by the assay manufacturer (4.45 vs. 4.20 mIU/L) but the lower limit was not (0.56 vs. 0.27 mIU/L). This finding may have a clinical impact since these values may lead to the misdiagnosis of euthyroid patients with subclinical hyperthyroidism. |
format | Online Article Text |
id | pubmed-10522077 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Sociedade Brasileira de Endocrinologia e Metabologia |
record_format | MEDLINE/PubMed |
spelling | pubmed-105220772023-09-27 Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil Gurgel, Maria Helane C Ponte, Clarisse M. M. Fontes, Rosita Rocha, Ítalo V. Batista, Lívia A. A. Sousa, Tamara C. S. Montenegro, Renan M. Arch Endocrinol Metab Original Article OBJECTIVE: This study aimed to determine the thyroid-stimulating hormone (TSH) reference interval (RI) and to assess the influence of the use of thyroid ultrasonography (TUS) on reference individual selection from a healthy adult population in Fortaleza, Brazil. SUBJECTS AND METHODS: This cross-sectional study recruited patients (N = 272; age = 18-50 years) with normal thyroid function (NTF) and placed them in three groups according to their test results: NTF (n = 272; all participants), TUS (n = 170; participants who underwent thyroid US), RI (n = 124; reference individuals with normal TSH levels). TSH, FT4, TT3, TgAb, and TPOAb concentrations were determined by electrochemiluminescence assay. TUS was performed using a 7-12 MHz multifrequency linear transducer by two radiologists. The 2.5(th) and 97.5(th) percentiles of the distribution curve corresponded to lower and upper TSH RI levels, respectively. RESULTS: The mean TSH level was 1.74 ± 0.96 mIU/L, and TSH range was 0.56-4.45 mIU/L. There was no difference in the TSH concentrations between men and women nor between the groups. TUS did not appear to be an essential tool for the reference group selection. CONCLUSION: The upper limit of TSH was comparable to the reference interval provided by the assay manufacturer (4.45 vs. 4.20 mIU/L) but the lower limit was not (0.56 vs. 0.27 mIU/L). This finding may have a clinical impact since these values may lead to the misdiagnosis of euthyroid patients with subclinical hyperthyroidism. Sociedade Brasileira de Endocrinologia e Metabologia 2020-07-17 /pmc/articles/PMC10522077/ /pubmed/32725064 http://dx.doi.org/10.20945/2359-3997000000264 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Gurgel, Maria Helane C Ponte, Clarisse M. M. Fontes, Rosita Rocha, Ítalo V. Batista, Lívia A. A. Sousa, Tamara C. S. Montenegro, Renan M. Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil |
title | Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil |
title_full | Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil |
title_fullStr | Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil |
title_full_unstemmed | Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil |
title_short | Establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from Fortaleza, Brazil |
title_sort | establishment of reference interval for thyroid-stimulating hormone using electrochemiluminescence assay in a healthy adult population from fortaleza, brazil |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10522077/ https://www.ncbi.nlm.nih.gov/pubmed/32725064 http://dx.doi.org/10.20945/2359-3997000000264 |
work_keys_str_mv | AT gurgelmariahelanec establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil AT ponteclarissemm establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil AT fontesrosita establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil AT rochaitalov establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil AT batistaliviaaa establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil AT sousatamaracs establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil AT montenegrorenanm establishmentofreferenceintervalforthyroidstimulatinghormoneusingelectrochemiluminescenceassayinahealthyadultpopulationfromfortalezabrazil |