Cargando…

Long-Term Follow-Up of Colonoscopy Quality Monitoring

INTRODUCTION: High-quality colonoscopy is paramount for colorectal cancer prevention. Since 2009, endoscopists at our institution have received quarterly report cards summarizing individual colonoscopy quality indicators. We have previously shown that implementing this intervention was associated wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Patel, Feenalie, Dilly, Christen, Fayad, Nabil, Marri, Smitha, Eckert, George J., Kahi, Charles
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10522096/
https://www.ncbi.nlm.nih.gov/pubmed/37436181
http://dx.doi.org/10.14309/ctg.0000000000000608
Descripción
Sumario:INTRODUCTION: High-quality colonoscopy is paramount for colorectal cancer prevention. Since 2009, endoscopists at our institution have received quarterly report cards summarizing individual colonoscopy quality indicators. We have previously shown that implementing this intervention was associated with short-term improvement in adenoma detection rate (ADR). However, the long-term effect of continued monitoring on colonoscopy quality is unclear. METHODS: We conducted a retrospective study of prospectively administered quarterly colonoscopy quality report cards at the Roudebush Veteran's Affairs Medical Center between April 1, 2012, and August 31, 2019. The anonymized reports included individual endoscopists' ADRs, cecal intubation rates, and withdrawal times. Analyses were performed to determine slopes over time for each quality metric by physician and assess for differences based on whether ADRs were calculated quarterly or yearly. RESULTS: Data from the report cards of 17 endoscopists who had performed 24,361 colonoscopies were included. The mean quarterly ADR (±SD) was 51.7% (±11.7%) and mean yearly ADR was 47.2% (±13.8%). There was a small increase in overall ADR based on quarterly and yearly measurements (slope + 0.6%, P = 0.02; and slope +2.7%, P < 0.001, respectively), but no significant change in individual ADRs, cecal intubation rates, or withdrawal times. Analysis of SD of ADRs showed no significant difference between yearly and quarterly measurements (P = 0.064). Individual endoscopists' ADR SD differences between yearly and quarterly measurements ranged from −4.7% to +6.8%. DISCUSSION: Long-term colonoscopy quality monitoring paralleled stable improvements in overall ADR. For endoscopists with baseline high ADR, frequent monitoring and reporting of colonoscopy quality metrics may not be necessary.