Cargando…

A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor

We present a novel and easy approach using a silicon-based impedance chip to determine the concentration of the given aqueous buffer solution. An accurate determination of the post-dilution concentration of the buffers is necessary for ensuring optimal buffer capacity, pH stability, and to assess so...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhat, Vinayak J., Blaschke, Daniel, Müller, Elke, Ehricht, Ralf, Schmidt, Heidemarie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10527345/
https://www.ncbi.nlm.nih.gov/pubmed/37754075
http://dx.doi.org/10.3390/bios13090841
_version_ 1785111139326099456
author Bhat, Vinayak J.
Blaschke, Daniel
Müller, Elke
Ehricht, Ralf
Schmidt, Heidemarie
author_facet Bhat, Vinayak J.
Blaschke, Daniel
Müller, Elke
Ehricht, Ralf
Schmidt, Heidemarie
author_sort Bhat, Vinayak J.
collection PubMed
description We present a novel and easy approach using a silicon-based impedance chip to determine the concentration of the given aqueous buffer solution. An accurate determination of the post-dilution concentration of the buffers is necessary for ensuring optimal buffer capacity, pH stability, and to assess solution reproducibility. In this study, we focused on phosphate buffer as the test liquid to achieve precise post-dilution concentration determinations. The impedance chip consisting of a top gold ring electrode, where a test volume of 20 μL to 30 μL of phosphate buffer was introduced for impedance measurements within the frequency range of 40 Hz to 1 MHz. For impedance investigation, we used phosphate buffers with three different pH values, and the impedance was measured after diluting the phosphate buffers to a concentration of 1.00 M, 0.75 M, 0.50 M, 0.25 M, 0.10 M, 0.05 M, and 0.01 M. In order to analyze the distinctive changes in the measured impedance, an equivalent circuit was proposed and modeled. From the impedance modeling, we report that the circuit parameter R(Au/Si) showed exponential dependence on the concentration of phosphate buffer and no dependence on the pH values of the phosphate buffer and on the added volume inside the ring electrode. The proposed silicon-based impedance chip is quick and uses reduced liquid volume for post-dilution concentration measurements of buffers and has perspective applications in the pharmaceutical and biological domains for regulating, monitoring, and quality control of the buffers.
format Online
Article
Text
id pubmed-10527345
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105273452023-09-28 A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor Bhat, Vinayak J. Blaschke, Daniel Müller, Elke Ehricht, Ralf Schmidt, Heidemarie Biosensors (Basel) Article We present a novel and easy approach using a silicon-based impedance chip to determine the concentration of the given aqueous buffer solution. An accurate determination of the post-dilution concentration of the buffers is necessary for ensuring optimal buffer capacity, pH stability, and to assess solution reproducibility. In this study, we focused on phosphate buffer as the test liquid to achieve precise post-dilution concentration determinations. The impedance chip consisting of a top gold ring electrode, where a test volume of 20 μL to 30 μL of phosphate buffer was introduced for impedance measurements within the frequency range of 40 Hz to 1 MHz. For impedance investigation, we used phosphate buffers with three different pH values, and the impedance was measured after diluting the phosphate buffers to a concentration of 1.00 M, 0.75 M, 0.50 M, 0.25 M, 0.10 M, 0.05 M, and 0.01 M. In order to analyze the distinctive changes in the measured impedance, an equivalent circuit was proposed and modeled. From the impedance modeling, we report that the circuit parameter R(Au/Si) showed exponential dependence on the concentration of phosphate buffer and no dependence on the pH values of the phosphate buffer and on the added volume inside the ring electrode. The proposed silicon-based impedance chip is quick and uses reduced liquid volume for post-dilution concentration measurements of buffers and has perspective applications in the pharmaceutical and biological domains for regulating, monitoring, and quality control of the buffers. MDPI 2023-08-24 /pmc/articles/PMC10527345/ /pubmed/37754075 http://dx.doi.org/10.3390/bios13090841 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bhat, Vinayak J.
Blaschke, Daniel
Müller, Elke
Ehricht, Ralf
Schmidt, Heidemarie
A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor
title A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor
title_full A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor
title_fullStr A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor
title_full_unstemmed A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor
title_short A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor
title_sort novel approach to monitor the concentration of phosphate buffers in the range of 1 m to 0.1 m using a silicon-based impedance sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10527345/
https://www.ncbi.nlm.nih.gov/pubmed/37754075
http://dx.doi.org/10.3390/bios13090841
work_keys_str_mv AT bhatvinayakj anovelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT blaschkedaniel anovelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT mullerelke anovelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT ehrichtralf anovelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT schmidtheidemarie anovelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT bhatvinayakj novelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT blaschkedaniel novelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT mullerelke novelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT ehrichtralf novelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor
AT schmidtheidemarie novelapproachtomonitortheconcentrationofphosphatebuffersintherangeof1mto01musingasiliconbasedimpedancesensor