Cargando…
Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection
Accurate determination of serotonin (ST) provides insight into neurological processes and enables applications in clinical diagnostics of brain diseases. Herein, we present an electrochemical aptasensor based on truncated DNA aptamers and a polyethylene glycol (PEG) molecule-functionalized sensing i...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10527390/ https://www.ncbi.nlm.nih.gov/pubmed/37754115 http://dx.doi.org/10.3390/bios13090881 |
_version_ | 1785111146299129856 |
---|---|
author | Hu, Ziheng Zhu, Ruifeng Figueroa-Miranda, Gabriela Zhou, Lei Feng, Lingyan Offenhäusser, Andreas Mayer, Dirk |
author_facet | Hu, Ziheng Zhu, Ruifeng Figueroa-Miranda, Gabriela Zhou, Lei Feng, Lingyan Offenhäusser, Andreas Mayer, Dirk |
author_sort | Hu, Ziheng |
collection | PubMed |
description | Accurate determination of serotonin (ST) provides insight into neurological processes and enables applications in clinical diagnostics of brain diseases. Herein, we present an electrochemical aptasensor based on truncated DNA aptamers and a polyethylene glycol (PEG) molecule-functionalized sensing interface for highly sensitive and selective ST detection. The truncated aptamers have a small size and adopt a stable stem-loop configuration, which improves the accessibility of the aptamer for the analyte and enhances the sensitivity of the aptasensor. Upon target binding, these aptamers perform a conformational change, leading to a variation in the Faraday current of the redox tag, which was recorded by square wave voltammetry (SWV). Using PEG as blocking molecules minimizes nonspecific adsorption of other interfering molecules and thus endows an enhanced antifouling ability. The proposed electrochemical aptamer sensor showed a wide range of detection lasting from 0.1 nM to 1000 nM with a low limit of detection of 0.14 nM. Owing to the unique properties of aptamer receptors, the aptasensor also exhibits high selectivity and stability. Furthermore, with the reduced unspecific adsorption, assaying of ST in human serum and artificial cerebrospinal fluid (aCSF) showed excellent performance. The reported strategy of utilizing antifouling PEG describes a novel approach to building antifouling aptasensors and holds great potential for neurochemical investigations and clinical diagnosis. |
format | Online Article Text |
id | pubmed-10527390 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105273902023-09-28 Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection Hu, Ziheng Zhu, Ruifeng Figueroa-Miranda, Gabriela Zhou, Lei Feng, Lingyan Offenhäusser, Andreas Mayer, Dirk Biosensors (Basel) Article Accurate determination of serotonin (ST) provides insight into neurological processes and enables applications in clinical diagnostics of brain diseases. Herein, we present an electrochemical aptasensor based on truncated DNA aptamers and a polyethylene glycol (PEG) molecule-functionalized sensing interface for highly sensitive and selective ST detection. The truncated aptamers have a small size and adopt a stable stem-loop configuration, which improves the accessibility of the aptamer for the analyte and enhances the sensitivity of the aptasensor. Upon target binding, these aptamers perform a conformational change, leading to a variation in the Faraday current of the redox tag, which was recorded by square wave voltammetry (SWV). Using PEG as blocking molecules minimizes nonspecific adsorption of other interfering molecules and thus endows an enhanced antifouling ability. The proposed electrochemical aptamer sensor showed a wide range of detection lasting from 0.1 nM to 1000 nM with a low limit of detection of 0.14 nM. Owing to the unique properties of aptamer receptors, the aptasensor also exhibits high selectivity and stability. Furthermore, with the reduced unspecific adsorption, assaying of ST in human serum and artificial cerebrospinal fluid (aCSF) showed excellent performance. The reported strategy of utilizing antifouling PEG describes a novel approach to building antifouling aptasensors and holds great potential for neurochemical investigations and clinical diagnosis. MDPI 2023-09-11 /pmc/articles/PMC10527390/ /pubmed/37754115 http://dx.doi.org/10.3390/bios13090881 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hu, Ziheng Zhu, Ruifeng Figueroa-Miranda, Gabriela Zhou, Lei Feng, Lingyan Offenhäusser, Andreas Mayer, Dirk Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection |
title | Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection |
title_full | Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection |
title_fullStr | Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection |
title_full_unstemmed | Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection |
title_short | Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection |
title_sort | truncated electrochemical aptasensor with enhanced antifouling capability for highly sensitive serotonin detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10527390/ https://www.ncbi.nlm.nih.gov/pubmed/37754115 http://dx.doi.org/10.3390/bios13090881 |
work_keys_str_mv | AT huziheng truncatedelectrochemicalaptasensorwithenhancedantifoulingcapabilityforhighlysensitiveserotonindetection AT zhuruifeng truncatedelectrochemicalaptasensorwithenhancedantifoulingcapabilityforhighlysensitiveserotonindetection AT figueroamirandagabriela truncatedelectrochemicalaptasensorwithenhancedantifoulingcapabilityforhighlysensitiveserotonindetection AT zhoulei truncatedelectrochemicalaptasensorwithenhancedantifoulingcapabilityforhighlysensitiveserotonindetection AT fenglingyan truncatedelectrochemicalaptasensorwithenhancedantifoulingcapabilityforhighlysensitiveserotonindetection AT offenhausserandreas truncatedelectrochemicalaptasensorwithenhancedantifoulingcapabilityforhighlysensitiveserotonindetection AT mayerdirk truncatedelectrochemicalaptasensorwithenhancedantifoulingcapabilityforhighlysensitiveserotonindetection |