Cargando…

Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients

Background: The aim of our study was to evaluate the diagnostic capacity of the tear meniscus osmolarity measurement for dry eye disease (DED) in patients with rheumatoid arthritis (RA), using a portable osmometer based on electrical impedance and an integrated circuit technology (TearLab(®) (Escond...

Descripción completa

Detalles Bibliográficos
Autores principales: De La Parra-Colin, Paola, Palacios-Aguirre, Karen, Perez-Pria-Kasusky, Andrea, Espinosa-Morales, Rolando, Hidalgo-Bravo, Alberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10528091/
https://www.ncbi.nlm.nih.gov/pubmed/37761361
http://dx.doi.org/10.3390/diagnostics13182994
_version_ 1785111223822450688
author De La Parra-Colin, Paola
Palacios-Aguirre, Karen
Perez-Pria-Kasusky, Andrea
Espinosa-Morales, Rolando
Hidalgo-Bravo, Alberto
author_facet De La Parra-Colin, Paola
Palacios-Aguirre, Karen
Perez-Pria-Kasusky, Andrea
Espinosa-Morales, Rolando
Hidalgo-Bravo, Alberto
author_sort De La Parra-Colin, Paola
collection PubMed
description Background: The aim of our study was to evaluate the diagnostic capacity of the tear meniscus osmolarity measurement for dry eye disease (DED) in patients with rheumatoid arthritis (RA), using a portable osmometer based on electrical impedance and an integrated circuit technology (TearLab(®) (Escondido, CA, USA)). Methods: We included 101 RA patients, 81 patients with DED and 20 without DED (controls). We measured tear osmolarity and assessed other clinical diagnostic tests as suggested by the TFOS DEWS II composite reference standard diagnostic criteria for DED using Ocular Surface Disease Index (OSDI), Five-item Dry Eye Questionnaire (DEQ-5), fluorescein tear break-up time (F-TUBT), ocular surface staining (SICCA score), and other clinical parameters to classify DED subtypes. We analyzed the agreement between osmolarity and the TFOS DEWS II composite reference standard for DED diagnosis. We conducted receiver operating characteristic (ROC) curve analyses using the DED variable and its subtypes as dependent variables and the continuous variable for osmolarity or the inter-eye difference in osmolarity as independent variable. Sensitivity, specificity, and area under the curve for all potential cut-off points were obtained and reported from ROC curves. Results: We found that tear meniscus osmolarity had a low diagnostic capacity for DED (AUC = 0.57). Tear meniscus osmolarity measurement had a sensitivity of 35% and a specificity of 80% with a kappa level of agreement of 0.08 compared to the TFOS DEWS II composite reference standard. The low diagnostic capacity of the tear meniscus osmolarity was similar for aqueous-deficient DED and for evaporative DED, being only fair for severe DED with a 57% sensitivity and 80% specificity and a kappa level of agreement of 0.36. Conclusions: Our findings suggest that in patients with RA, tear meniscus osmolarity measured by the TearLab(®) showed low sensitivity, low specificity, and limited agreement with the TFOS DEWS II composite reference standard for DED diagnosis.
format Online
Article
Text
id pubmed-10528091
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105280912023-09-28 Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients De La Parra-Colin, Paola Palacios-Aguirre, Karen Perez-Pria-Kasusky, Andrea Espinosa-Morales, Rolando Hidalgo-Bravo, Alberto Diagnostics (Basel) Article Background: The aim of our study was to evaluate the diagnostic capacity of the tear meniscus osmolarity measurement for dry eye disease (DED) in patients with rheumatoid arthritis (RA), using a portable osmometer based on electrical impedance and an integrated circuit technology (TearLab(®) (Escondido, CA, USA)). Methods: We included 101 RA patients, 81 patients with DED and 20 without DED (controls). We measured tear osmolarity and assessed other clinical diagnostic tests as suggested by the TFOS DEWS II composite reference standard diagnostic criteria for DED using Ocular Surface Disease Index (OSDI), Five-item Dry Eye Questionnaire (DEQ-5), fluorescein tear break-up time (F-TUBT), ocular surface staining (SICCA score), and other clinical parameters to classify DED subtypes. We analyzed the agreement between osmolarity and the TFOS DEWS II composite reference standard for DED diagnosis. We conducted receiver operating characteristic (ROC) curve analyses using the DED variable and its subtypes as dependent variables and the continuous variable for osmolarity or the inter-eye difference in osmolarity as independent variable. Sensitivity, specificity, and area under the curve for all potential cut-off points were obtained and reported from ROC curves. Results: We found that tear meniscus osmolarity had a low diagnostic capacity for DED (AUC = 0.57). Tear meniscus osmolarity measurement had a sensitivity of 35% and a specificity of 80% with a kappa level of agreement of 0.08 compared to the TFOS DEWS II composite reference standard. The low diagnostic capacity of the tear meniscus osmolarity was similar for aqueous-deficient DED and for evaporative DED, being only fair for severe DED with a 57% sensitivity and 80% specificity and a kappa level of agreement of 0.36. Conclusions: Our findings suggest that in patients with RA, tear meniscus osmolarity measured by the TearLab(®) showed low sensitivity, low specificity, and limited agreement with the TFOS DEWS II composite reference standard for DED diagnosis. MDPI 2023-09-19 /pmc/articles/PMC10528091/ /pubmed/37761361 http://dx.doi.org/10.3390/diagnostics13182994 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
De La Parra-Colin, Paola
Palacios-Aguirre, Karen
Perez-Pria-Kasusky, Andrea
Espinosa-Morales, Rolando
Hidalgo-Bravo, Alberto
Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients
title Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients
title_full Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients
title_fullStr Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients
title_full_unstemmed Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients
title_short Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients
title_sort diagnostic performance of the tear meniscus osmolarity measurement for dry eye disease in rheumatoid arthritis patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10528091/
https://www.ncbi.nlm.nih.gov/pubmed/37761361
http://dx.doi.org/10.3390/diagnostics13182994
work_keys_str_mv AT delaparracolinpaola diagnosticperformanceofthetearmeniscusosmolaritymeasurementfordryeyediseaseinrheumatoidarthritispatients
AT palaciosaguirrekaren diagnosticperformanceofthetearmeniscusosmolaritymeasurementfordryeyediseaseinrheumatoidarthritispatients
AT perezpriakasuskyandrea diagnosticperformanceofthetearmeniscusosmolaritymeasurementfordryeyediseaseinrheumatoidarthritispatients
AT espinosamoralesrolando diagnosticperformanceofthetearmeniscusosmolaritymeasurementfordryeyediseaseinrheumatoidarthritispatients
AT hidalgobravoalberto diagnosticperformanceofthetearmeniscusosmolaritymeasurementfordryeyediseaseinrheumatoidarthritispatients