Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression—An In Vitro Study

The accuracy for the implant position transfer of a mounting fixture and a standardized open-tray implant level impression was compared. Ten aluminum master models with four implant analogs placed in different angulations were fabricated. By performing an open-tray implant level impression stone cas...

Descripción completa

Detalles Bibliográficos
Autores principales: Becker, Alexander, Dirksen, Dieter, Runte, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10529300/
https://www.ncbi.nlm.nih.gov/pubmed/37754328
http://dx.doi.org/10.3390/dj11090208
_version_ 1785111371431542784
author Becker, Alexander
Dirksen, Dieter
Runte, Christoph
author_facet Becker, Alexander
Dirksen, Dieter
Runte, Christoph
author_sort Becker, Alexander
collection PubMed
description The accuracy for the implant position transfer of a mounting fixture and a standardized open-tray implant level impression was compared. Ten aluminum master models with four implant analogs placed in different angulations were fabricated. By performing an open-tray implant level impression stone casts were produced. The master models and stone casts were scanned (comparison group one) using a laboratory scanner. Deviations in the scan body surface were determined in the form of mean (absolute) point distances and (signed) surface distances. The same procedure was performed with a screwed transfer and by fixing the posts of the mounting fixture (comparison group two). The mounting device was applied to each master model and scanned in a fixed and detached state (comparison group three). In a point comparison, the open-tray implant level impression showed mean deviations of 43.6 µm and a mounting fixture of 44.6 µm with no significant differences (p < 0.05). There were significant differences between groups two and three. The angulation of the implants had no effect on the accuracy. In a surface comparison, the open-tray implant level impression showed mean deviations of 36.0 µm and a mounting fixture of 2.0 µm (p > 0.05). Within the limits of this study, the mounting fixture transferred the implant position with the same accuracy as the open-tray implant level impression with respect to point deviations.
format Online
Article
Text
id pubmed-10529300
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105293002023-09-28 Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression—An In Vitro Study Becker, Alexander Dirksen, Dieter Runte, Christoph Dent J (Basel) Article The accuracy for the implant position transfer of a mounting fixture and a standardized open-tray implant level impression was compared. Ten aluminum master models with four implant analogs placed in different angulations were fabricated. By performing an open-tray implant level impression stone casts were produced. The master models and stone casts were scanned (comparison group one) using a laboratory scanner. Deviations in the scan body surface were determined in the form of mean (absolute) point distances and (signed) surface distances. The same procedure was performed with a screwed transfer and by fixing the posts of the mounting fixture (comparison group two). The mounting device was applied to each master model and scanned in a fixed and detached state (comparison group three). In a point comparison, the open-tray implant level impression showed mean deviations of 43.6 µm and a mounting fixture of 44.6 µm with no significant differences (p < 0.05). There were significant differences between groups two and three. The angulation of the implants had no effect on the accuracy. In a surface comparison, the open-tray implant level impression showed mean deviations of 36.0 µm and a mounting fixture of 2.0 µm (p > 0.05). Within the limits of this study, the mounting fixture transferred the implant position with the same accuracy as the open-tray implant level impression with respect to point deviations. MDPI 2023-08-31 /pmc/articles/PMC10529300/ /pubmed/37754328 http://dx.doi.org/10.3390/dj11090208 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Becker, Alexander
Dirksen, Dieter
Runte, Christoph
Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression—An In Vitro Study
title Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression—An In Vitro Study
title_full Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression—An In Vitro Study
title_fullStr Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression—An In Vitro Study
title_full_unstemmed Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression—An In Vitro Study
title_short Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression—An In Vitro Study
title_sort comparison of the accuracy of a mounting fixture for dental implants for implant position transfer and open-tray implant level impression—an in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10529300/
https://www.ncbi.nlm.nih.gov/pubmed/37754328
http://dx.doi.org/10.3390/dj11090208
work_keys_str_mv AT beckeralexander comparisonoftheaccuracyofamountingfixturefordentalimplantsforimplantpositiontransferandopentrayimplantlevelimpressionaninvitrostudy
AT dirksendieter comparisonoftheaccuracyofamountingfixturefordentalimplantsforimplantpositiontransferandopentrayimplantlevelimpressionaninvitrostudy
AT runtechristoph comparisonoftheaccuracyofamountingfixturefordentalimplantsforimplantpositiontransferandopentrayimplantlevelimpressionaninvitrostudy