Cargando…

Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report

This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subje...

Descripción completa

Detalles Bibliográficos
Autores principales: Lopo Barros, José Henrique, de Oliveira, Murilo Navarro, Cardoso, Igor Oliveiros, de Oliveira, Guilherme José Pimentel Lopes, do Prado, Célio Jesus, Neves, Flávio Domingues Das
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10530779/
https://www.ncbi.nlm.nih.gov/pubmed/37761669
http://dx.doi.org/10.3390/healthcare11182472
_version_ 1785111565275496448
author Lopo Barros, José Henrique
de Oliveira, Murilo Navarro
Cardoso, Igor Oliveiros
de Oliveira, Guilherme José Pimentel Lopes
do Prado, Célio Jesus
Neves, Flávio Domingues Das
author_facet Lopo Barros, José Henrique
de Oliveira, Murilo Navarro
Cardoso, Igor Oliveiros
de Oliveira, Guilherme José Pimentel Lopes
do Prado, Célio Jesus
Neves, Flávio Domingues Das
author_sort Lopo Barros, José Henrique
collection PubMed
description This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations. After osseointegration, an intraoral scanning transfer provided a digital model (file extension .stl), which reproduced the implant’s position and inclination. Then, the file was sent so that a customized abutment (CAD/CAM) could be manufactured, promoting the final rehabilitation of the case; this allowed for good hygiene, load distribution in the dynamic interocclusal relationship, and favorable esthetics, whereas many would otherwise recommend implant removal. The result presented lower costs, a shorter time frame, and a lower morbidity for the patient.
format Online
Article
Text
id pubmed-10530779
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105307792023-09-28 Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report Lopo Barros, José Henrique de Oliveira, Murilo Navarro Cardoso, Igor Oliveiros de Oliveira, Guilherme José Pimentel Lopes do Prado, Célio Jesus Neves, Flávio Domingues Das Healthcare (Basel) Case Report This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations. After osseointegration, an intraoral scanning transfer provided a digital model (file extension .stl), which reproduced the implant’s position and inclination. Then, the file was sent so that a customized abutment (CAD/CAM) could be manufactured, promoting the final rehabilitation of the case; this allowed for good hygiene, load distribution in the dynamic interocclusal relationship, and favorable esthetics, whereas many would otherwise recommend implant removal. The result presented lower costs, a shorter time frame, and a lower morbidity for the patient. MDPI 2023-09-06 /pmc/articles/PMC10530779/ /pubmed/37761669 http://dx.doi.org/10.3390/healthcare11182472 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
Lopo Barros, José Henrique
de Oliveira, Murilo Navarro
Cardoso, Igor Oliveiros
de Oliveira, Guilherme José Pimentel Lopes
do Prado, Célio Jesus
Neves, Flávio Domingues Das
Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report
title Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report
title_full Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report
title_fullStr Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report
title_full_unstemmed Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report
title_short Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report
title_sort computer-aided design/computer-aided manufacturing of customized abutment for rehabilitating a malpositioned implant using digital flow: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10530779/
https://www.ncbi.nlm.nih.gov/pubmed/37761669
http://dx.doi.org/10.3390/healthcare11182472
work_keys_str_mv AT lopobarrosjosehenrique computeraideddesigncomputeraidedmanufacturingofcustomizedabutmentforrehabilitatingamalpositionedimplantusingdigitalflowacasereport
AT deoliveiramurilonavarro computeraideddesigncomputeraidedmanufacturingofcustomizedabutmentforrehabilitatingamalpositionedimplantusingdigitalflowacasereport
AT cardosoigoroliveiros computeraideddesigncomputeraidedmanufacturingofcustomizedabutmentforrehabilitatingamalpositionedimplantusingdigitalflowacasereport
AT deoliveiraguilhermejosepimentellopes computeraideddesigncomputeraidedmanufacturingofcustomizedabutmentforrehabilitatingamalpositionedimplantusingdigitalflowacasereport
AT dopradoceliojesus computeraideddesigncomputeraidedmanufacturingofcustomizedabutmentforrehabilitatingamalpositionedimplantusingdigitalflowacasereport
AT nevesflaviodominguesdas computeraideddesigncomputeraidedmanufacturingofcustomizedabutmentforrehabilitatingamalpositionedimplantusingdigitalflowacasereport