Cargando…

Measuring Up: A Comparison of TapeStation 4200 and Bioanalyzer 2100 as Measurement Tools for RNA Quality in Postmortem Human Brain Samples

The determination of RNA integrity is a critical quality assessment tool for gene expression studies where the experiment’s success is highly dependent on the sample quality. Since its introduction in 1999, the gold standard in the scientific community has been the Agilent 2100 Bioanalyzer’s RNA int...

Descripción completa

Detalles Bibliográficos
Autores principales: Walker, Jessica E., Oliver, Javon C., Stewart, Analisa M., Beh, Suet Theng, Arce, Richard A., Glass, Michael J., Vargas, Daisy E., Qiji, Sanaria H., Intorcia, Anthony J., Borja, Claryssa I., Cline, Madison P., Hemmingsen, Spencer J., Krupp, Addison N., McHattie, Rylee D., Mariner, Monica R., Lorenzini, Ileana, Aslam, Sidra, Tremblay, Cecilia, Beach, Thomas G., Serrano, Geidy E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10531353/
https://www.ncbi.nlm.nih.gov/pubmed/37762097
http://dx.doi.org/10.3390/ijms241813795
_version_ 1785111698512805888
author Walker, Jessica E.
Oliver, Javon C.
Stewart, Analisa M.
Beh, Suet Theng
Arce, Richard A.
Glass, Michael J.
Vargas, Daisy E.
Qiji, Sanaria H.
Intorcia, Anthony J.
Borja, Claryssa I.
Cline, Madison P.
Hemmingsen, Spencer J.
Krupp, Addison N.
McHattie, Rylee D.
Mariner, Monica R.
Lorenzini, Ileana
Aslam, Sidra
Tremblay, Cecilia
Beach, Thomas G.
Serrano, Geidy E.
author_facet Walker, Jessica E.
Oliver, Javon C.
Stewart, Analisa M.
Beh, Suet Theng
Arce, Richard A.
Glass, Michael J.
Vargas, Daisy E.
Qiji, Sanaria H.
Intorcia, Anthony J.
Borja, Claryssa I.
Cline, Madison P.
Hemmingsen, Spencer J.
Krupp, Addison N.
McHattie, Rylee D.
Mariner, Monica R.
Lorenzini, Ileana
Aslam, Sidra
Tremblay, Cecilia
Beach, Thomas G.
Serrano, Geidy E.
author_sort Walker, Jessica E.
collection PubMed
description The determination of RNA integrity is a critical quality assessment tool for gene expression studies where the experiment’s success is highly dependent on the sample quality. Since its introduction in 1999, the gold standard in the scientific community has been the Agilent 2100 Bioanalyzer’s RNA integrity number (RIN), which uses a 1–10 value system, from 1 being the most degraded, to 10 being the most intact. In 2015, Agilent launched 4200 TapeStation’s RIN equivalent, and reported a strong correlation of r(2) of 0.936 and a median error < ±0.4 RIN units. To evaluate this claim, we compared the Agilent 4200 TapeStation’s RIN equivalent (RINe) and DV200 to the Agilent 2100 Bioanalyzer’s RIN for 183 parallel RNA samples. In our study, using RNA from a total of 183 human postmortem brain samples, we found that the RIN and RINe values only weakly correlate, with an r(2) of 0.393 and an average difference of 3.2 RIN units. DV200 also only weakly correlated with RIN (r(2) of 0.182) and RINe (r(2) of 0.347). Finally, when applying a cut-off value of 6.5 for both metrics, we found that 95.6% of samples passed with RIN, while only 23.5% passed with RINe. Our results suggest that even though RIN (Bioanalyzer) and RINe (TapeStation) use the same 1–10 value system, they should not be used interchangeably, and cut-off values should be calculated independently.
format Online
Article
Text
id pubmed-10531353
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105313532023-09-28 Measuring Up: A Comparison of TapeStation 4200 and Bioanalyzer 2100 as Measurement Tools for RNA Quality in Postmortem Human Brain Samples Walker, Jessica E. Oliver, Javon C. Stewart, Analisa M. Beh, Suet Theng Arce, Richard A. Glass, Michael J. Vargas, Daisy E. Qiji, Sanaria H. Intorcia, Anthony J. Borja, Claryssa I. Cline, Madison P. Hemmingsen, Spencer J. Krupp, Addison N. McHattie, Rylee D. Mariner, Monica R. Lorenzini, Ileana Aslam, Sidra Tremblay, Cecilia Beach, Thomas G. Serrano, Geidy E. Int J Mol Sci Communication The determination of RNA integrity is a critical quality assessment tool for gene expression studies where the experiment’s success is highly dependent on the sample quality. Since its introduction in 1999, the gold standard in the scientific community has been the Agilent 2100 Bioanalyzer’s RNA integrity number (RIN), which uses a 1–10 value system, from 1 being the most degraded, to 10 being the most intact. In 2015, Agilent launched 4200 TapeStation’s RIN equivalent, and reported a strong correlation of r(2) of 0.936 and a median error < ±0.4 RIN units. To evaluate this claim, we compared the Agilent 4200 TapeStation’s RIN equivalent (RINe) and DV200 to the Agilent 2100 Bioanalyzer’s RIN for 183 parallel RNA samples. In our study, using RNA from a total of 183 human postmortem brain samples, we found that the RIN and RINe values only weakly correlate, with an r(2) of 0.393 and an average difference of 3.2 RIN units. DV200 also only weakly correlated with RIN (r(2) of 0.182) and RINe (r(2) of 0.347). Finally, when applying a cut-off value of 6.5 for both metrics, we found that 95.6% of samples passed with RIN, while only 23.5% passed with RINe. Our results suggest that even though RIN (Bioanalyzer) and RINe (TapeStation) use the same 1–10 value system, they should not be used interchangeably, and cut-off values should be calculated independently. MDPI 2023-09-07 /pmc/articles/PMC10531353/ /pubmed/37762097 http://dx.doi.org/10.3390/ijms241813795 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Walker, Jessica E.
Oliver, Javon C.
Stewart, Analisa M.
Beh, Suet Theng
Arce, Richard A.
Glass, Michael J.
Vargas, Daisy E.
Qiji, Sanaria H.
Intorcia, Anthony J.
Borja, Claryssa I.
Cline, Madison P.
Hemmingsen, Spencer J.
Krupp, Addison N.
McHattie, Rylee D.
Mariner, Monica R.
Lorenzini, Ileana
Aslam, Sidra
Tremblay, Cecilia
Beach, Thomas G.
Serrano, Geidy E.
Measuring Up: A Comparison of TapeStation 4200 and Bioanalyzer 2100 as Measurement Tools for RNA Quality in Postmortem Human Brain Samples
title Measuring Up: A Comparison of TapeStation 4200 and Bioanalyzer 2100 as Measurement Tools for RNA Quality in Postmortem Human Brain Samples
title_full Measuring Up: A Comparison of TapeStation 4200 and Bioanalyzer 2100 as Measurement Tools for RNA Quality in Postmortem Human Brain Samples
title_fullStr Measuring Up: A Comparison of TapeStation 4200 and Bioanalyzer 2100 as Measurement Tools for RNA Quality in Postmortem Human Brain Samples
title_full_unstemmed Measuring Up: A Comparison of TapeStation 4200 and Bioanalyzer 2100 as Measurement Tools for RNA Quality in Postmortem Human Brain Samples
title_short Measuring Up: A Comparison of TapeStation 4200 and Bioanalyzer 2100 as Measurement Tools for RNA Quality in Postmortem Human Brain Samples
title_sort measuring up: a comparison of tapestation 4200 and bioanalyzer 2100 as measurement tools for rna quality in postmortem human brain samples
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10531353/
https://www.ncbi.nlm.nih.gov/pubmed/37762097
http://dx.doi.org/10.3390/ijms241813795
work_keys_str_mv AT walkerjessicae measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT oliverjavonc measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT stewartanalisam measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT behsuettheng measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT arcericharda measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT glassmichaelj measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT vargasdaisye measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT qijisanariah measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT intorciaanthonyj measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT borjaclaryssai measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT clinemadisonp measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT hemmingsenspencerj measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT kruppaddisonn measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT mchattieryleed measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT marinermonicar measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT lorenziniileana measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT aslamsidra measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT tremblaycecilia measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT beachthomasg measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples
AT serranogeidye measuringupacomparisonoftapestation4200andbioanalyzer2100asmeasurementtoolsforrnaqualityinpostmortemhumanbrainsamples