Cargando…

Method Development for Determination of Doripenem in Human Plasma via Capillary Electrophoresis Coupled with Field-Enhanced Sample Stacking and Sweeping

In this study, we established a novel capillary electrophoresis method for monitoring the concentration of doripenem in human plasma. As a time-dependent antibiotic, doripenem maximizes its antibacterial effects and minimizes the potential for antibiotic resistance through careful therapeutic drug m...

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Hsin-Hua, Lin, Yu-Chao, Hung, Chin-Chuan, Hou, Yu-Chi, Lin, Yi-Hui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10531396/
https://www.ncbi.nlm.nih.gov/pubmed/37762057
http://dx.doi.org/10.3390/ijms241813751
Descripción
Sumario:In this study, we established a novel capillary electrophoresis method for monitoring the concentration of doripenem in human plasma. As a time-dependent antibiotic, doripenem maximizes its antibacterial effects and minimizes the potential for antibiotic resistance through careful therapeutic drug monitoring. Two online preconcentration techniques, field-enhanced sample stacking (FESS) and sweeping, were coupled to enhance the detection sensitivity. Briefly, an uncoated fused silica capillary (40 cm × 50 μm i.d) was rinsed with a high conductivity buffer (HCB) composed of 150 mM phosphate buffer (NaH(2)PO(4), pH 2.5) and 20% methanol. A large sample plug prepared in a low-conductivity phosphate buffer (50 mM NaH(2)PO(4), pH 2.5) was then hydrodynamically injected (5 psi, 80 s) into the capillary. Under an applied voltage of −30 kV, the analyte was accumulated at the FESS boundary and swept by the negatively charged micelles toward the UV detector. Plasma samples were pretreated by solid-phase extraction (SPE) to eliminate endogenous interferences. The validation results demonstrated a high coefficient of determination (r(2) > 0.9995) for the regression curve with impressive precision and accuracy: relative standard deviation (RSD) <5.86% and relative error <4.63%. The limit of detection (LOD, S/N = 3) for doripenem was determined to be 0.4 μg/mL. Compared to the conventional micellar electrokinetic chromatography method, our developed method achieved a sensitivity enhancement of up to 488-fold for doripenem. Furthermore, the newly developed method successfully quantified doripenem concentrations in plasma samples obtained from patients accepting doripenem regimens, proving its application potential in the clinical realm.