Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis

(1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths...

Descripción completa

Detalles Bibliográficos
Autores principales: Stoilov, Milan, Shafaghi, Ramin, Stark, Helmut, Marder, Michael, Kraus, Dominik, Enkling, Norbert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10531925/
https://www.ncbi.nlm.nih.gov/pubmed/37754883
http://dx.doi.org/10.3390/jfb14090469
_version_ 1785111835360362496
author Stoilov, Milan
Shafaghi, Ramin
Stark, Helmut
Marder, Michael
Kraus, Dominik
Enkling, Norbert
author_facet Stoilov, Milan
Shafaghi, Ramin
Stark, Helmut
Marder, Michael
Kraus, Dominik
Enkling, Norbert
author_sort Stoilov, Milan
collection PubMed
description (1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths and diameters were inserted into polyurethane foam blocks of different densities (35, 25, 15, and 10 PCF) using standard drilling protocols. Primary stability was assessed through insertion torque (IT) and resonance frequency analysis (RFA). Optimal ranges were defined for IT (25 to 50 Ncm) and RFA (ISQ 60 to 80). A comparison of implant groups was conducted to determine adherence to the optimal ranges. (3) Results: Implant macro-design, -length, and -diameter and bone block density significantly influenced IT and RFA. Optimal IT was observed in 8/40 and 9/40 groups for the parallel-walled implants, while the tapered implant achieved optimal IT in 13/40 groups (within a 25–50 Ncm range). Implant diameter strongly impacted primary stability, with sufficient stability achieved in only one-third of cases despite the tapered implant’s superiority. (4) Conclusions: The findings highlight the need to adapt the drilling protocol based on diverse bone qualities in clinical practice. Further investigations should explore the impact of these adapted protocols on implant outcomes.
format Online
Article
Text
id pubmed-10531925
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105319252023-09-28 Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis Stoilov, Milan Shafaghi, Ramin Stark, Helmut Marder, Michael Kraus, Dominik Enkling, Norbert J Funct Biomater Article (1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths and diameters were inserted into polyurethane foam blocks of different densities (35, 25, 15, and 10 PCF) using standard drilling protocols. Primary stability was assessed through insertion torque (IT) and resonance frequency analysis (RFA). Optimal ranges were defined for IT (25 to 50 Ncm) and RFA (ISQ 60 to 80). A comparison of implant groups was conducted to determine adherence to the optimal ranges. (3) Results: Implant macro-design, -length, and -diameter and bone block density significantly influenced IT and RFA. Optimal IT was observed in 8/40 and 9/40 groups for the parallel-walled implants, while the tapered implant achieved optimal IT in 13/40 groups (within a 25–50 Ncm range). Implant diameter strongly impacted primary stability, with sufficient stability achieved in only one-third of cases despite the tapered implant’s superiority. (4) Conclusions: The findings highlight the need to adapt the drilling protocol based on diverse bone qualities in clinical practice. Further investigations should explore the impact of these adapted protocols on implant outcomes. MDPI 2023-09-12 /pmc/articles/PMC10531925/ /pubmed/37754883 http://dx.doi.org/10.3390/jfb14090469 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Stoilov, Milan
Shafaghi, Ramin
Stark, Helmut
Marder, Michael
Kraus, Dominik
Enkling, Norbert
Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis
title Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis
title_full Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis
title_fullStr Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis
title_full_unstemmed Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis
title_short Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis
title_sort influence of implant macro-design, -length, and -diameter on primary implant stability depending on different bone qualities using standard drilling protocols—an in vitro analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10531925/
https://www.ncbi.nlm.nih.gov/pubmed/37754883
http://dx.doi.org/10.3390/jfb14090469
work_keys_str_mv AT stoilovmilan influenceofimplantmacrodesignlengthanddiameteronprimaryimplantstabilitydependingondifferentbonequalitiesusingstandarddrillingprotocolsaninvitroanalysis
AT shafaghiramin influenceofimplantmacrodesignlengthanddiameteronprimaryimplantstabilitydependingondifferentbonequalitiesusingstandarddrillingprotocolsaninvitroanalysis
AT starkhelmut influenceofimplantmacrodesignlengthanddiameteronprimaryimplantstabilitydependingondifferentbonequalitiesusingstandarddrillingprotocolsaninvitroanalysis
AT mardermichael influenceofimplantmacrodesignlengthanddiameteronprimaryimplantstabilitydependingondifferentbonequalitiesusingstandarddrillingprotocolsaninvitroanalysis
AT krausdominik influenceofimplantmacrodesignlengthanddiameteronprimaryimplantstabilitydependingondifferentbonequalitiesusingstandarddrillingprotocolsaninvitroanalysis
AT enklingnorbert influenceofimplantmacrodesignlengthanddiameteronprimaryimplantstabilitydependingondifferentbonequalitiesusingstandarddrillingprotocolsaninvitroanalysis