Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors

Background: An accurate measurement of the glomerular filtration rate (GFR) is essential for detecting renal insufficiency in living kidney donors. Iohexol is a “near-ideal” exogenous filtration marker for GFR measurements that has attracted increasing interest in clinical practice because it is non...

Descripción completa

Detalles Bibliográficos
Autores principales: Jin, Zhicheng, Huang, Rongrong, Christensen, Paul, Bertholf, Roger L., Yi, Xin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532236/
https://www.ncbi.nlm.nih.gov/pubmed/37762993
http://dx.doi.org/10.3390/jcm12186054
_version_ 1785111908473372672
author Jin, Zhicheng
Huang, Rongrong
Christensen, Paul
Bertholf, Roger L.
Yi, Xin
author_facet Jin, Zhicheng
Huang, Rongrong
Christensen, Paul
Bertholf, Roger L.
Yi, Xin
author_sort Jin, Zhicheng
collection PubMed
description Background: An accurate measurement of the glomerular filtration rate (GFR) is essential for detecting renal insufficiency in living kidney donors. Iohexol is a “near-ideal” exogenous filtration marker for GFR measurements that has attracted increasing interest in clinical practice because it is non-toxic, non-radioactive, readily available, and easy to measure. In this study, we aimed to set up a laboratory test to conveniently assess the plasma clearance of iohexol in living kidney donors. Methods: A workflow was established in the institution’s infusion clinic to administer iohexol and to collect three timed blood samples from renal transplant donors. Iohexol was thereafter measured by liquid chromatography–tandem mass spectrometry (LC-MS/MS). The serum proteins were precipitated and the supernatant containing iohexol was diluted prior to the LC-MS/MS analysis. The LC-MS/MS method was developed on a Thermo Vanquish UHPLC coupled with a TSQ Endura triple quadruple mass spectrometer with a total run time of 2.5 min. The analytical performance of the method was assessed. Results: The LC-MS/MS method demonstrated a good analytical performance. To calculate the iohexol clearance rate and the GFR, automated data integration and a result calculation were accomplished by using a custom Python script. Automated result reporting was achieved using a laboratory informatics system (LIS) vendor’s direct media interface. Conclusions: We developed and implemented a laboratory test to assess the plasma clearance of iohexol. A workflow was established in the hospital to reliably measure the GFR in living kidney donors, with a potential to be further expanded into other areas where an accurate GFR measurement is needed.
format Online
Article
Text
id pubmed-10532236
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105322362023-09-28 Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors Jin, Zhicheng Huang, Rongrong Christensen, Paul Bertholf, Roger L. Yi, Xin J Clin Med Article Background: An accurate measurement of the glomerular filtration rate (GFR) is essential for detecting renal insufficiency in living kidney donors. Iohexol is a “near-ideal” exogenous filtration marker for GFR measurements that has attracted increasing interest in clinical practice because it is non-toxic, non-radioactive, readily available, and easy to measure. In this study, we aimed to set up a laboratory test to conveniently assess the plasma clearance of iohexol in living kidney donors. Methods: A workflow was established in the institution’s infusion clinic to administer iohexol and to collect three timed blood samples from renal transplant donors. Iohexol was thereafter measured by liquid chromatography–tandem mass spectrometry (LC-MS/MS). The serum proteins were precipitated and the supernatant containing iohexol was diluted prior to the LC-MS/MS analysis. The LC-MS/MS method was developed on a Thermo Vanquish UHPLC coupled with a TSQ Endura triple quadruple mass spectrometer with a total run time of 2.5 min. The analytical performance of the method was assessed. Results: The LC-MS/MS method demonstrated a good analytical performance. To calculate the iohexol clearance rate and the GFR, automated data integration and a result calculation were accomplished by using a custom Python script. Automated result reporting was achieved using a laboratory informatics system (LIS) vendor’s direct media interface. Conclusions: We developed and implemented a laboratory test to assess the plasma clearance of iohexol. A workflow was established in the hospital to reliably measure the GFR in living kidney donors, with a potential to be further expanded into other areas where an accurate GFR measurement is needed. MDPI 2023-09-19 /pmc/articles/PMC10532236/ /pubmed/37762993 http://dx.doi.org/10.3390/jcm12186054 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jin, Zhicheng
Huang, Rongrong
Christensen, Paul
Bertholf, Roger L.
Yi, Xin
Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors
title Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors
title_full Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors
title_fullStr Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors
title_full_unstemmed Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors
title_short Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors
title_sort accuracy-based glomerular filtration rate assessment by plasma iohexol clearance in kidney transplant donors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532236/
https://www.ncbi.nlm.nih.gov/pubmed/37762993
http://dx.doi.org/10.3390/jcm12186054
work_keys_str_mv AT jinzhicheng accuracybasedglomerularfiltrationrateassessmentbyplasmaiohexolclearanceinkidneytransplantdonors
AT huangrongrong accuracybasedglomerularfiltrationrateassessmentbyplasmaiohexolclearanceinkidneytransplantdonors
AT christensenpaul accuracybasedglomerularfiltrationrateassessmentbyplasmaiohexolclearanceinkidneytransplantdonors
AT bertholfrogerl accuracybasedglomerularfiltrationrateassessmentbyplasmaiohexolclearanceinkidneytransplantdonors
AT yixin accuracybasedglomerularfiltrationrateassessmentbyplasmaiohexolclearanceinkidneytransplantdonors