Cargando…
Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications
To regulate the degradation rate and improve the surface biocompatibility of the AZ31B magnesium alloy, three different coating systems were produced via plasma electrolytic oxidation (PEO): simple PEO, PEO incorporating multi-walled carbon nanotubes (PEO + CNT), and a duplex coating that included a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532417/ https://www.ncbi.nlm.nih.gov/pubmed/37754889 http://dx.doi.org/10.3390/jfb14090475 |
_version_ | 1785111955456917504 |
---|---|
author | Daavari, Morteza Atapour, Masoud Mohedano, Marta Matykina, Endzhe Arrabal, Raul Nesic, Dobrila |
author_facet | Daavari, Morteza Atapour, Masoud Mohedano, Marta Matykina, Endzhe Arrabal, Raul Nesic, Dobrila |
author_sort | Daavari, Morteza |
collection | PubMed |
description | To regulate the degradation rate and improve the surface biocompatibility of the AZ31B magnesium alloy, three different coating systems were produced via plasma electrolytic oxidation (PEO): simple PEO, PEO incorporating multi-walled carbon nanotubes (PEO + CNT), and a duplex coating that included a polycaprolactone top layer (PEO + CNT/PCL). Surfaces were characterized by chemical content, roughness, topography, and wettability. Biological properties analysis included cell metabolism and adhesion. PEO ± CNT resulted in an augmented surface roughness compared with the base material (BM), while PCL deposition produced the smoothest surface. All surfaces had a contact angle below 90°. The exposure of gFib-TERT and bmMSC to culture media collected after 3 or 24 h did not affect their metabolism. A decrease in metabolic activity of 9% and 14% for bmMSC and of 14% and 29% for gFib-TERT was observed after 3 and 7 days, respectively. All cells died after 7 days of exposure to BM and after 15 days of exposure to coated surfaces. Saos-2 and gFib-TERT adhered poorly to BM, in contrast to bmMSC. All cells on PEO anchored into the pores with filopodia, exhibited tiny adhesion protrusions on PEO + CNT, and presented a web-like spreading with lamellipodia on PEO + CNT/PCL. The smooth and homogenous surface of the duplex PEO + CNT/PCL coating decreased magnesium corrosion and led to better biological functionality. |
format | Online Article Text |
id | pubmed-10532417 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105324172023-09-28 Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications Daavari, Morteza Atapour, Masoud Mohedano, Marta Matykina, Endzhe Arrabal, Raul Nesic, Dobrila J Funct Biomater Article To regulate the degradation rate and improve the surface biocompatibility of the AZ31B magnesium alloy, three different coating systems were produced via plasma electrolytic oxidation (PEO): simple PEO, PEO incorporating multi-walled carbon nanotubes (PEO + CNT), and a duplex coating that included a polycaprolactone top layer (PEO + CNT/PCL). Surfaces were characterized by chemical content, roughness, topography, and wettability. Biological properties analysis included cell metabolism and adhesion. PEO ± CNT resulted in an augmented surface roughness compared with the base material (BM), while PCL deposition produced the smoothest surface. All surfaces had a contact angle below 90°. The exposure of gFib-TERT and bmMSC to culture media collected after 3 or 24 h did not affect their metabolism. A decrease in metabolic activity of 9% and 14% for bmMSC and of 14% and 29% for gFib-TERT was observed after 3 and 7 days, respectively. All cells died after 7 days of exposure to BM and after 15 days of exposure to coated surfaces. Saos-2 and gFib-TERT adhered poorly to BM, in contrast to bmMSC. All cells on PEO anchored into the pores with filopodia, exhibited tiny adhesion protrusions on PEO + CNT, and presented a web-like spreading with lamellipodia on PEO + CNT/PCL. The smooth and homogenous surface of the duplex PEO + CNT/PCL coating decreased magnesium corrosion and led to better biological functionality. MDPI 2023-09-16 /pmc/articles/PMC10532417/ /pubmed/37754889 http://dx.doi.org/10.3390/jfb14090475 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Daavari, Morteza Atapour, Masoud Mohedano, Marta Matykina, Endzhe Arrabal, Raul Nesic, Dobrila Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications |
title | Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications |
title_full | Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications |
title_fullStr | Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications |
title_full_unstemmed | Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications |
title_short | Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications |
title_sort | biological performance of duplex peo + cnt/pcl coating on az31b mg alloy for orthopedic and dental applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532417/ https://www.ncbi.nlm.nih.gov/pubmed/37754889 http://dx.doi.org/10.3390/jfb14090475 |
work_keys_str_mv | AT daavarimorteza biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications AT atapourmasoud biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications AT mohedanomarta biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications AT matykinaendzhe biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications AT arrabalraul biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications AT nesicdobrila biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications |