Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications

To regulate the degradation rate and improve the surface biocompatibility of the AZ31B magnesium alloy, three different coating systems were produced via plasma electrolytic oxidation (PEO): simple PEO, PEO incorporating multi-walled carbon nanotubes (PEO + CNT), and a duplex coating that included a...

Descripción completa

Detalles Bibliográficos
Autores principales: Daavari, Morteza, Atapour, Masoud, Mohedano, Marta, Matykina, Endzhe, Arrabal, Raul, Nesic, Dobrila
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532417/
https://www.ncbi.nlm.nih.gov/pubmed/37754889
http://dx.doi.org/10.3390/jfb14090475
_version_ 1785111955456917504
author Daavari, Morteza
Atapour, Masoud
Mohedano, Marta
Matykina, Endzhe
Arrabal, Raul
Nesic, Dobrila
author_facet Daavari, Morteza
Atapour, Masoud
Mohedano, Marta
Matykina, Endzhe
Arrabal, Raul
Nesic, Dobrila
author_sort Daavari, Morteza
collection PubMed
description To regulate the degradation rate and improve the surface biocompatibility of the AZ31B magnesium alloy, three different coating systems were produced via plasma electrolytic oxidation (PEO): simple PEO, PEO incorporating multi-walled carbon nanotubes (PEO + CNT), and a duplex coating that included a polycaprolactone top layer (PEO + CNT/PCL). Surfaces were characterized by chemical content, roughness, topography, and wettability. Biological properties analysis included cell metabolism and adhesion. PEO ± CNT resulted in an augmented surface roughness compared with the base material (BM), while PCL deposition produced the smoothest surface. All surfaces had a contact angle below 90°. The exposure of gFib-TERT and bmMSC to culture media collected after 3 or 24 h did not affect their metabolism. A decrease in metabolic activity of 9% and 14% for bmMSC and of 14% and 29% for gFib-TERT was observed after 3 and 7 days, respectively. All cells died after 7 days of exposure to BM and after 15 days of exposure to coated surfaces. Saos-2 and gFib-TERT adhered poorly to BM, in contrast to bmMSC. All cells on PEO anchored into the pores with filopodia, exhibited tiny adhesion protrusions on PEO + CNT, and presented a web-like spreading with lamellipodia on PEO + CNT/PCL. The smooth and homogenous surface of the duplex PEO + CNT/PCL coating decreased magnesium corrosion and led to better biological functionality.
format Online
Article
Text
id pubmed-10532417
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105324172023-09-28 Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications Daavari, Morteza Atapour, Masoud Mohedano, Marta Matykina, Endzhe Arrabal, Raul Nesic, Dobrila J Funct Biomater Article To regulate the degradation rate and improve the surface biocompatibility of the AZ31B magnesium alloy, three different coating systems were produced via plasma electrolytic oxidation (PEO): simple PEO, PEO incorporating multi-walled carbon nanotubes (PEO + CNT), and a duplex coating that included a polycaprolactone top layer (PEO + CNT/PCL). Surfaces were characterized by chemical content, roughness, topography, and wettability. Biological properties analysis included cell metabolism and adhesion. PEO ± CNT resulted in an augmented surface roughness compared with the base material (BM), while PCL deposition produced the smoothest surface. All surfaces had a contact angle below 90°. The exposure of gFib-TERT and bmMSC to culture media collected after 3 or 24 h did not affect their metabolism. A decrease in metabolic activity of 9% and 14% for bmMSC and of 14% and 29% for gFib-TERT was observed after 3 and 7 days, respectively. All cells died after 7 days of exposure to BM and after 15 days of exposure to coated surfaces. Saos-2 and gFib-TERT adhered poorly to BM, in contrast to bmMSC. All cells on PEO anchored into the pores with filopodia, exhibited tiny adhesion protrusions on PEO + CNT, and presented a web-like spreading with lamellipodia on PEO + CNT/PCL. The smooth and homogenous surface of the duplex PEO + CNT/PCL coating decreased magnesium corrosion and led to better biological functionality. MDPI 2023-09-16 /pmc/articles/PMC10532417/ /pubmed/37754889 http://dx.doi.org/10.3390/jfb14090475 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Daavari, Morteza
Atapour, Masoud
Mohedano, Marta
Matykina, Endzhe
Arrabal, Raul
Nesic, Dobrila
Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications
title Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications
title_full Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications
title_fullStr Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications
title_full_unstemmed Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications
title_short Biological Performance of Duplex PEO + CNT/PCL Coating on AZ31B Mg Alloy for Orthopedic and Dental Applications
title_sort biological performance of duplex peo + cnt/pcl coating on az31b mg alloy for orthopedic and dental applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532417/
https://www.ncbi.nlm.nih.gov/pubmed/37754889
http://dx.doi.org/10.3390/jfb14090475
work_keys_str_mv AT daavarimorteza biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications
AT atapourmasoud biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications
AT mohedanomarta biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications
AT matykinaendzhe biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications
AT arrabalraul biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications
AT nesicdobrila biologicalperformanceofduplexpeocntpclcoatingonaz31bmgalloyfororthopedicanddentalapplications