Cargando…

Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images

This study investigated the long-term effects of epiretinal membrane (ERM) surgery on peripapillary retinal nerve fiber layer (RNFL) thickness using optical coherence tomography (OCT) images. We included 30 patients with idiopathic ERM who underwent a vitrectomy for ERM removal with internal limitin...

Descripción completa

Detalles Bibliográficos
Autores principales: Bae, Ki Woong, Kim, Dong Ik, Hwang, Daniel Duck-Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532953/
https://www.ncbi.nlm.nih.gov/pubmed/37763208
http://dx.doi.org/10.3390/life13091804
_version_ 1785112082701615104
author Bae, Ki Woong
Kim, Dong Ik
Hwang, Daniel Duck-Jin
author_facet Bae, Ki Woong
Kim, Dong Ik
Hwang, Daniel Duck-Jin
author_sort Bae, Ki Woong
collection PubMed
description This study investigated the long-term effects of epiretinal membrane (ERM) surgery on peripapillary retinal nerve fiber layer (RNFL) thickness using optical coherence tomography (OCT) images. We included 30 patients with idiopathic ERM who underwent a vitrectomy for ERM removal with internal limiting membrane peeling. The patients were followed up for 5 years after surgery, and their medical records were reviewed for best-corrected visual acuity (BCVA) and OCT parameters. The study population comprised 24 females (80.0%), and the mean age was 65.4 ± 7.2 years. The baseline BCVA significantly improved from 0.28 ± 0.24 to 0.12 ± 0.09 logMAR (p < 0.001) 1 year after surgery and continued to improve for 5 years after surgery. The peripapillary RNFL thickness initially increased after surgery and then gradually decreased. The peripapillary RNFL thicknesses of the global and temporal sectors showed significant reductions 2 years after surgery, whereas those of the nasal sectors did not significantly change. The peripapillary RNFL thickness was thinner in the global and temporal areas of the operated eyes than in those of the fellow eyes 4 and 5 years after surgery. In conclusion, peripapillary RNFL thicknesses decreased in the global and temporal areas after ERM surgery, whereas peripapillary RNFL thicknesses in the nasal sectors did not change significantly during the long-term follow-up.
format Online
Article
Text
id pubmed-10532953
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105329532023-09-28 Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images Bae, Ki Woong Kim, Dong Ik Hwang, Daniel Duck-Jin Life (Basel) Article This study investigated the long-term effects of epiretinal membrane (ERM) surgery on peripapillary retinal nerve fiber layer (RNFL) thickness using optical coherence tomography (OCT) images. We included 30 patients with idiopathic ERM who underwent a vitrectomy for ERM removal with internal limiting membrane peeling. The patients were followed up for 5 years after surgery, and their medical records were reviewed for best-corrected visual acuity (BCVA) and OCT parameters. The study population comprised 24 females (80.0%), and the mean age was 65.4 ± 7.2 years. The baseline BCVA significantly improved from 0.28 ± 0.24 to 0.12 ± 0.09 logMAR (p < 0.001) 1 year after surgery and continued to improve for 5 years after surgery. The peripapillary RNFL thickness initially increased after surgery and then gradually decreased. The peripapillary RNFL thicknesses of the global and temporal sectors showed significant reductions 2 years after surgery, whereas those of the nasal sectors did not significantly change. The peripapillary RNFL thickness was thinner in the global and temporal areas of the operated eyes than in those of the fellow eyes 4 and 5 years after surgery. In conclusion, peripapillary RNFL thicknesses decreased in the global and temporal areas after ERM surgery, whereas peripapillary RNFL thicknesses in the nasal sectors did not change significantly during the long-term follow-up. MDPI 2023-08-24 /pmc/articles/PMC10532953/ /pubmed/37763208 http://dx.doi.org/10.3390/life13091804 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bae, Ki Woong
Kim, Dong Ik
Hwang, Daniel Duck-Jin
Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images
title Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images
title_full Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images
title_fullStr Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images
title_full_unstemmed Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images
title_short Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images
title_sort long-term changes in retinal nerve fiber layer thickness after vitrectomy for epiretinal membrane using optical coherence tomography images
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532953/
https://www.ncbi.nlm.nih.gov/pubmed/37763208
http://dx.doi.org/10.3390/life13091804
work_keys_str_mv AT baekiwoong longtermchangesinretinalnervefiberlayerthicknessaftervitrectomyforepiretinalmembraneusingopticalcoherencetomographyimages
AT kimdongik longtermchangesinretinalnervefiberlayerthicknessaftervitrectomyforepiretinalmembraneusingopticalcoherencetomographyimages
AT hwangdanielduckjin longtermchangesinretinalnervefiberlayerthicknessaftervitrectomyforepiretinalmembraneusingopticalcoherencetomographyimages