Cargando…
Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images
This study investigated the long-term effects of epiretinal membrane (ERM) surgery on peripapillary retinal nerve fiber layer (RNFL) thickness using optical coherence tomography (OCT) images. We included 30 patients with idiopathic ERM who underwent a vitrectomy for ERM removal with internal limitin...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532953/ https://www.ncbi.nlm.nih.gov/pubmed/37763208 http://dx.doi.org/10.3390/life13091804 |
_version_ | 1785112082701615104 |
---|---|
author | Bae, Ki Woong Kim, Dong Ik Hwang, Daniel Duck-Jin |
author_facet | Bae, Ki Woong Kim, Dong Ik Hwang, Daniel Duck-Jin |
author_sort | Bae, Ki Woong |
collection | PubMed |
description | This study investigated the long-term effects of epiretinal membrane (ERM) surgery on peripapillary retinal nerve fiber layer (RNFL) thickness using optical coherence tomography (OCT) images. We included 30 patients with idiopathic ERM who underwent a vitrectomy for ERM removal with internal limiting membrane peeling. The patients were followed up for 5 years after surgery, and their medical records were reviewed for best-corrected visual acuity (BCVA) and OCT parameters. The study population comprised 24 females (80.0%), and the mean age was 65.4 ± 7.2 years. The baseline BCVA significantly improved from 0.28 ± 0.24 to 0.12 ± 0.09 logMAR (p < 0.001) 1 year after surgery and continued to improve for 5 years after surgery. The peripapillary RNFL thickness initially increased after surgery and then gradually decreased. The peripapillary RNFL thicknesses of the global and temporal sectors showed significant reductions 2 years after surgery, whereas those of the nasal sectors did not significantly change. The peripapillary RNFL thickness was thinner in the global and temporal areas of the operated eyes than in those of the fellow eyes 4 and 5 years after surgery. In conclusion, peripapillary RNFL thicknesses decreased in the global and temporal areas after ERM surgery, whereas peripapillary RNFL thicknesses in the nasal sectors did not change significantly during the long-term follow-up. |
format | Online Article Text |
id | pubmed-10532953 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105329532023-09-28 Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images Bae, Ki Woong Kim, Dong Ik Hwang, Daniel Duck-Jin Life (Basel) Article This study investigated the long-term effects of epiretinal membrane (ERM) surgery on peripapillary retinal nerve fiber layer (RNFL) thickness using optical coherence tomography (OCT) images. We included 30 patients with idiopathic ERM who underwent a vitrectomy for ERM removal with internal limiting membrane peeling. The patients were followed up for 5 years after surgery, and their medical records were reviewed for best-corrected visual acuity (BCVA) and OCT parameters. The study population comprised 24 females (80.0%), and the mean age was 65.4 ± 7.2 years. The baseline BCVA significantly improved from 0.28 ± 0.24 to 0.12 ± 0.09 logMAR (p < 0.001) 1 year after surgery and continued to improve for 5 years after surgery. The peripapillary RNFL thickness initially increased after surgery and then gradually decreased. The peripapillary RNFL thicknesses of the global and temporal sectors showed significant reductions 2 years after surgery, whereas those of the nasal sectors did not significantly change. The peripapillary RNFL thickness was thinner in the global and temporal areas of the operated eyes than in those of the fellow eyes 4 and 5 years after surgery. In conclusion, peripapillary RNFL thicknesses decreased in the global and temporal areas after ERM surgery, whereas peripapillary RNFL thicknesses in the nasal sectors did not change significantly during the long-term follow-up. MDPI 2023-08-24 /pmc/articles/PMC10532953/ /pubmed/37763208 http://dx.doi.org/10.3390/life13091804 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bae, Ki Woong Kim, Dong Ik Hwang, Daniel Duck-Jin Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images |
title | Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images |
title_full | Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images |
title_fullStr | Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images |
title_full_unstemmed | Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images |
title_short | Long-Term Changes in Retinal Nerve Fiber Layer Thickness after Vitrectomy for Epiretinal Membrane Using Optical Coherence Tomography Images |
title_sort | long-term changes in retinal nerve fiber layer thickness after vitrectomy for epiretinal membrane using optical coherence tomography images |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10532953/ https://www.ncbi.nlm.nih.gov/pubmed/37763208 http://dx.doi.org/10.3390/life13091804 |
work_keys_str_mv | AT baekiwoong longtermchangesinretinalnervefiberlayerthicknessaftervitrectomyforepiretinalmembraneusingopticalcoherencetomographyimages AT kimdongik longtermchangesinretinalnervefiberlayerthicknessaftervitrectomyforepiretinalmembraneusingopticalcoherencetomographyimages AT hwangdanielduckjin longtermchangesinretinalnervefiberlayerthicknessaftervitrectomyforepiretinalmembraneusingopticalcoherencetomographyimages |