Cargando…
Comparison of Sublimation 3D Scanning Sprays in Terms of Their Effect on the Resulting 3D Scan, Thickness, and Sublimation Time
This study compared eight sublimation scanning sprays in terms of their effect on 3D scanning results, coating thickness, and sublimation time. The work used an automated spraying system to ensure the same deposition conditions for all tested materials. All experiments were performed under the same...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10533109/ https://www.ncbi.nlm.nih.gov/pubmed/37763443 http://dx.doi.org/10.3390/ma16186165 |
_version_ | 1785112120058183680 |
---|---|
author | Franke, Jakub Koutecký, Tomáš Koutný, Daniel |
author_facet | Franke, Jakub Koutecký, Tomáš Koutný, Daniel |
author_sort | Franke, Jakub |
collection | PubMed |
description | This study compared eight sublimation scanning sprays in terms of their effect on 3D scanning results, coating thickness, and sublimation time. The work used an automated spraying system to ensure the same deposition conditions for all tested materials. All experiments were performed under the same environmental conditions to exclude the influence of the ambient environment on the coatings. All tested scanning sprays created coatings with thicknesses in the order of tens of micrometers that were detectable by the 3D scanner Atos III Triple Scan. The coatings must be applied carefully when accurate measurements are required. All used materials enabled the capture of the highly reflective surface of the Si-wafer. However, the differences between some sprays were significant. Sublimation time measurements showed that all coatings disappeared from the Si-wafer surface completely. Nevertheless, all coatings left visible traces on the mirror-like surface. They were easily wiped off with a cloth. |
format | Online Article Text |
id | pubmed-10533109 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105331092023-09-28 Comparison of Sublimation 3D Scanning Sprays in Terms of Their Effect on the Resulting 3D Scan, Thickness, and Sublimation Time Franke, Jakub Koutecký, Tomáš Koutný, Daniel Materials (Basel) Article This study compared eight sublimation scanning sprays in terms of their effect on 3D scanning results, coating thickness, and sublimation time. The work used an automated spraying system to ensure the same deposition conditions for all tested materials. All experiments were performed under the same environmental conditions to exclude the influence of the ambient environment on the coatings. All tested scanning sprays created coatings with thicknesses in the order of tens of micrometers that were detectable by the 3D scanner Atos III Triple Scan. The coatings must be applied carefully when accurate measurements are required. All used materials enabled the capture of the highly reflective surface of the Si-wafer. However, the differences between some sprays were significant. Sublimation time measurements showed that all coatings disappeared from the Si-wafer surface completely. Nevertheless, all coatings left visible traces on the mirror-like surface. They were easily wiped off with a cloth. MDPI 2023-09-11 /pmc/articles/PMC10533109/ /pubmed/37763443 http://dx.doi.org/10.3390/ma16186165 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Franke, Jakub Koutecký, Tomáš Koutný, Daniel Comparison of Sublimation 3D Scanning Sprays in Terms of Their Effect on the Resulting 3D Scan, Thickness, and Sublimation Time |
title | Comparison of Sublimation 3D Scanning Sprays in Terms of Their Effect on the Resulting 3D Scan, Thickness, and Sublimation Time |
title_full | Comparison of Sublimation 3D Scanning Sprays in Terms of Their Effect on the Resulting 3D Scan, Thickness, and Sublimation Time |
title_fullStr | Comparison of Sublimation 3D Scanning Sprays in Terms of Their Effect on the Resulting 3D Scan, Thickness, and Sublimation Time |
title_full_unstemmed | Comparison of Sublimation 3D Scanning Sprays in Terms of Their Effect on the Resulting 3D Scan, Thickness, and Sublimation Time |
title_short | Comparison of Sublimation 3D Scanning Sprays in Terms of Their Effect on the Resulting 3D Scan, Thickness, and Sublimation Time |
title_sort | comparison of sublimation 3d scanning sprays in terms of their effect on the resulting 3d scan, thickness, and sublimation time |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10533109/ https://www.ncbi.nlm.nih.gov/pubmed/37763443 http://dx.doi.org/10.3390/ma16186165 |
work_keys_str_mv | AT frankejakub comparisonofsublimation3dscanningspraysintermsoftheireffectontheresulting3dscanthicknessandsublimationtime AT kouteckytomas comparisonofsublimation3dscanningspraysintermsoftheireffectontheresulting3dscanthicknessandsublimationtime AT koutnydaniel comparisonofsublimation3dscanningspraysintermsoftheireffectontheresulting3dscanthicknessandsublimationtime |