Cargando…

Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis

The extra-articular distal humerus plate (EADHP) has been widely used for surgical treatment of distal humerus shaft fracture (DHSF). However, the surgical approach, fixation methods, and implant positions of the EADHP remain controversial owing to iatrogenic radial nerve injury and complaints such...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jung-Soo, Kim, Kwang Gi, Yoon, Yong-Cheol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10533898/
https://www.ncbi.nlm.nih.gov/pubmed/37758839
http://dx.doi.org/10.1038/s41598-023-43183-x
_version_ 1785112274703220736
author Lee, Jung-Soo
Kim, Kwang Gi
Yoon, Yong-Cheol
author_facet Lee, Jung-Soo
Kim, Kwang Gi
Yoon, Yong-Cheol
author_sort Lee, Jung-Soo
collection PubMed
description The extra-articular distal humerus plate (EADHP) has been widely used for surgical treatment of distal humerus shaft fracture (DHSF). However, the surgical approach, fixation methods, and implant positions of the EADHP remain controversial owing to iatrogenic radial nerve injury and complaints such as skin irritation related to the plate. Anterior plating with a modified (upside-down application) proximal humerus locking plate (PHILOS) has been proposed as an alternative, However, research on its biomechanical performance remain insufficient and were mostly based on retrospective studies. This study quantitatively compared and evaluated the biomechanical performance between posterior plating with the EADHP and anterior plating with a modified PHILOS using finite element analysis (FEA). The FEA simulation results that both the EADHP and PHILOS had adequate biomechanical performance and stability under axial, bending, and varus force load conditions. The PHILOS has a fixed stability comparable to that of the EADHP, and fixation was achieved using only four locking screws within a fixed range of 30 mm just above the olecranon fossa. The results show that the PHILOS could be an option for the fixation of a DHSF when considering the dissection range and complaints (e.g. skin irritation) associated with the EADHP.
format Online
Article
Text
id pubmed-10533898
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-105338982023-09-29 Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis Lee, Jung-Soo Kim, Kwang Gi Yoon, Yong-Cheol Sci Rep Article The extra-articular distal humerus plate (EADHP) has been widely used for surgical treatment of distal humerus shaft fracture (DHSF). However, the surgical approach, fixation methods, and implant positions of the EADHP remain controversial owing to iatrogenic radial nerve injury and complaints such as skin irritation related to the plate. Anterior plating with a modified (upside-down application) proximal humerus locking plate (PHILOS) has been proposed as an alternative, However, research on its biomechanical performance remain insufficient and were mostly based on retrospective studies. This study quantitatively compared and evaluated the biomechanical performance between posterior plating with the EADHP and anterior plating with a modified PHILOS using finite element analysis (FEA). The FEA simulation results that both the EADHP and PHILOS had adequate biomechanical performance and stability under axial, bending, and varus force load conditions. The PHILOS has a fixed stability comparable to that of the EADHP, and fixation was achieved using only four locking screws within a fixed range of 30 mm just above the olecranon fossa. The results show that the PHILOS could be an option for the fixation of a DHSF when considering the dissection range and complaints (e.g. skin irritation) associated with the EADHP. Nature Publishing Group UK 2023-09-27 /pmc/articles/PMC10533898/ /pubmed/37758839 http://dx.doi.org/10.1038/s41598-023-43183-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Lee, Jung-Soo
Kim, Kwang Gi
Yoon, Yong-Cheol
Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
title Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
title_full Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
title_fullStr Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
title_full_unstemmed Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
title_short Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
title_sort biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10533898/
https://www.ncbi.nlm.nih.gov/pubmed/37758839
http://dx.doi.org/10.1038/s41598-023-43183-x
work_keys_str_mv AT leejungsoo biomechanicalperformanceevaluationofamodifiedproximalhumeruslockingplatefordistalhumerusshaftfractureusingfiniteelementanalysis
AT kimkwanggi biomechanicalperformanceevaluationofamodifiedproximalhumeruslockingplatefordistalhumerusshaftfractureusingfiniteelementanalysis
AT yoonyongcheol biomechanicalperformanceevaluationofamodifiedproximalhumeruslockingplatefordistalhumerusshaftfractureusingfiniteelementanalysis