Differentiation of Body Fluid Stains Using a Portable, Low-Cost Ion Mobility Spectrometry Device—A Pilot Study

The identification and recovery of suspected human biofluid evidence can present a bottleneck in the crime scene investigation workflow. Crime Scene Investigators typically deploy one of a number of presumptive enhancement reagents, depending on what they perceive an analyte to be; the selection of...

Descripción completa

Detalles Bibliográficos
Autores principales: Heaton, Cameron, Clement, Simon, Kelly, Paul F., King, Roberto S. P., Reynolds, James C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10534372/
https://www.ncbi.nlm.nih.gov/pubmed/37764309
http://dx.doi.org/10.3390/molecules28186533
_version_ 1785112378695745536
author Heaton, Cameron
Clement, Simon
Kelly, Paul F.
King, Roberto S. P.
Reynolds, James C.
author_facet Heaton, Cameron
Clement, Simon
Kelly, Paul F.
King, Roberto S. P.
Reynolds, James C.
author_sort Heaton, Cameron
collection PubMed
description The identification and recovery of suspected human biofluid evidence can present a bottleneck in the crime scene investigation workflow. Crime Scene Investigators typically deploy one of a number of presumptive enhancement reagents, depending on what they perceive an analyte to be; the selection of this reagent is largely based on the context of suspected evidence and their professional experience. Positively identified samples are then recovered to a forensic laboratory where confirmatory testing is carried out by large lab-based instruments, such as through mass-spectrometry-based techniques. This work proposes a proof-of-concept study into the use of a small, robust and portable ion mobility spectrometry device that can analyse samples in situ, detecting, identifying and discriminating commonly encountered body fluids from interferences. This analysis exploits the detection and identification of characteristic volatile organic compounds generated by gentle heating, at ambient temperature and pressure, and categorises samples using machine learning, providing investigators with instant identification. The device is shown to be capable of producing characteristic mobility spectra using a dual micro disc pump configuration which separates blood and urine from three visually similar interferences using an unsupervised PCA model with no misclassified samples. The device has the potential to reduce the need for potentially contaminating and destructive presumptive tests, and address the bottleneck created by the time-consuming and laborious detection, recovery and analysis workflow currently employed.
format Online
Article
Text
id pubmed-10534372
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105343722023-09-29 Differentiation of Body Fluid Stains Using a Portable, Low-Cost Ion Mobility Spectrometry Device—A Pilot Study Heaton, Cameron Clement, Simon Kelly, Paul F. King, Roberto S. P. Reynolds, James C. Molecules Article The identification and recovery of suspected human biofluid evidence can present a bottleneck in the crime scene investigation workflow. Crime Scene Investigators typically deploy one of a number of presumptive enhancement reagents, depending on what they perceive an analyte to be; the selection of this reagent is largely based on the context of suspected evidence and their professional experience. Positively identified samples are then recovered to a forensic laboratory where confirmatory testing is carried out by large lab-based instruments, such as through mass-spectrometry-based techniques. This work proposes a proof-of-concept study into the use of a small, robust and portable ion mobility spectrometry device that can analyse samples in situ, detecting, identifying and discriminating commonly encountered body fluids from interferences. This analysis exploits the detection and identification of characteristic volatile organic compounds generated by gentle heating, at ambient temperature and pressure, and categorises samples using machine learning, providing investigators with instant identification. The device is shown to be capable of producing characteristic mobility spectra using a dual micro disc pump configuration which separates blood and urine from three visually similar interferences using an unsupervised PCA model with no misclassified samples. The device has the potential to reduce the need for potentially contaminating and destructive presumptive tests, and address the bottleneck created by the time-consuming and laborious detection, recovery and analysis workflow currently employed. MDPI 2023-09-09 /pmc/articles/PMC10534372/ /pubmed/37764309 http://dx.doi.org/10.3390/molecules28186533 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Heaton, Cameron
Clement, Simon
Kelly, Paul F.
King, Roberto S. P.
Reynolds, James C.
Differentiation of Body Fluid Stains Using a Portable, Low-Cost Ion Mobility Spectrometry Device—A Pilot Study
title Differentiation of Body Fluid Stains Using a Portable, Low-Cost Ion Mobility Spectrometry Device—A Pilot Study
title_full Differentiation of Body Fluid Stains Using a Portable, Low-Cost Ion Mobility Spectrometry Device—A Pilot Study
title_fullStr Differentiation of Body Fluid Stains Using a Portable, Low-Cost Ion Mobility Spectrometry Device—A Pilot Study
title_full_unstemmed Differentiation of Body Fluid Stains Using a Portable, Low-Cost Ion Mobility Spectrometry Device—A Pilot Study
title_short Differentiation of Body Fluid Stains Using a Portable, Low-Cost Ion Mobility Spectrometry Device—A Pilot Study
title_sort differentiation of body fluid stains using a portable, low-cost ion mobility spectrometry device—a pilot study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10534372/
https://www.ncbi.nlm.nih.gov/pubmed/37764309
http://dx.doi.org/10.3390/molecules28186533
work_keys_str_mv AT heatoncameron differentiationofbodyfluidstainsusingaportablelowcostionmobilityspectrometrydeviceapilotstudy
AT clementsimon differentiationofbodyfluidstainsusingaportablelowcostionmobilityspectrometrydeviceapilotstudy
AT kellypaulf differentiationofbodyfluidstainsusingaportablelowcostionmobilityspectrometrydeviceapilotstudy
AT kingrobertosp differentiationofbodyfluidstainsusingaportablelowcostionmobilityspectrometrydeviceapilotstudy
AT reynoldsjamesc differentiationofbodyfluidstainsusingaportablelowcostionmobilityspectrometrydeviceapilotstudy