Cargando…
Electrocatalytic Determination of Uric Acid with the Poly(Tartrazine)-Modified Pencil Graphite Electrode in Human Serum and Artificial Urine
[Image: see text] A novel electrocatalytic sensing strategy was built for uric acid (UA) determination with an exceptionally developed poly(tartrazine)-modified activated pencil graphite electrode (pTRT/aPGE) in human serum and artificial urine. The oxidation signal of UA at 275 mV in pH 7.5 phospha...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10535258/ https://www.ncbi.nlm.nih.gov/pubmed/37780010 http://dx.doi.org/10.1021/acsomega.3c02561 |
_version_ | 1785112588462325760 |
---|---|
author | Liv, Lokman Portakal, Merve Çukur, Meryem Sıla Topaçlı, Beyza Uzun, Berkay |
author_facet | Liv, Lokman Portakal, Merve Çukur, Meryem Sıla Topaçlı, Beyza Uzun, Berkay |
author_sort | Liv, Lokman |
collection | PubMed |
description | [Image: see text] A novel electrocatalytic sensing strategy was built for uric acid (UA) determination with an exceptionally developed poly(tartrazine)-modified activated pencil graphite electrode (pTRT/aPGE) in human serum and artificial urine. The oxidation signal of UA at 275 mV in pH 7.5 phosphate buffer solution served as the analytical response. Cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy were used to characterize the sensing platform, which was able to detect 0.10 μM of UA in the ranges of 0.34–60 and 70–140 μM. The samples of human serum and artificial urine were analyzed by both the pTRT/aPGE and the uricase-modified screen-printed electrode. The results were statistically evaluated and compared with each other within the confidence level of 95%, and no significant difference between the results was found. |
format | Online Article Text |
id | pubmed-10535258 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-105352582023-09-29 Electrocatalytic Determination of Uric Acid with the Poly(Tartrazine)-Modified Pencil Graphite Electrode in Human Serum and Artificial Urine Liv, Lokman Portakal, Merve Çukur, Meryem Sıla Topaçlı, Beyza Uzun, Berkay ACS Omega [Image: see text] A novel electrocatalytic sensing strategy was built for uric acid (UA) determination with an exceptionally developed poly(tartrazine)-modified activated pencil graphite electrode (pTRT/aPGE) in human serum and artificial urine. The oxidation signal of UA at 275 mV in pH 7.5 phosphate buffer solution served as the analytical response. Cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy were used to characterize the sensing platform, which was able to detect 0.10 μM of UA in the ranges of 0.34–60 and 70–140 μM. The samples of human serum and artificial urine were analyzed by both the pTRT/aPGE and the uricase-modified screen-printed electrode. The results were statistically evaluated and compared with each other within the confidence level of 95%, and no significant difference between the results was found. American Chemical Society 2023-09-11 /pmc/articles/PMC10535258/ /pubmed/37780010 http://dx.doi.org/10.1021/acsomega.3c02561 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Liv, Lokman Portakal, Merve Çukur, Meryem Sıla Topaçlı, Beyza Uzun, Berkay Electrocatalytic Determination of Uric Acid with the Poly(Tartrazine)-Modified Pencil Graphite Electrode in Human Serum and Artificial Urine |
title | Electrocatalytic
Determination of Uric Acid with the
Poly(Tartrazine)-Modified Pencil Graphite Electrode in Human Serum
and Artificial Urine |
title_full | Electrocatalytic
Determination of Uric Acid with the
Poly(Tartrazine)-Modified Pencil Graphite Electrode in Human Serum
and Artificial Urine |
title_fullStr | Electrocatalytic
Determination of Uric Acid with the
Poly(Tartrazine)-Modified Pencil Graphite Electrode in Human Serum
and Artificial Urine |
title_full_unstemmed | Electrocatalytic
Determination of Uric Acid with the
Poly(Tartrazine)-Modified Pencil Graphite Electrode in Human Serum
and Artificial Urine |
title_short | Electrocatalytic
Determination of Uric Acid with the
Poly(Tartrazine)-Modified Pencil Graphite Electrode in Human Serum
and Artificial Urine |
title_sort | electrocatalytic
determination of uric acid with the
poly(tartrazine)-modified pencil graphite electrode in human serum
and artificial urine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10535258/ https://www.ncbi.nlm.nih.gov/pubmed/37780010 http://dx.doi.org/10.1021/acsomega.3c02561 |
work_keys_str_mv | AT livlokman electrocatalyticdeterminationofuricacidwiththepolytartrazinemodifiedpencilgraphiteelectrodeinhumanserumandartificialurine AT portakalmerve electrocatalyticdeterminationofuricacidwiththepolytartrazinemodifiedpencilgraphiteelectrodeinhumanserumandartificialurine AT cukurmeryemsıla electrocatalyticdeterminationofuricacidwiththepolytartrazinemodifiedpencilgraphiteelectrodeinhumanserumandartificialurine AT topaclıbeyza electrocatalyticdeterminationofuricacidwiththepolytartrazinemodifiedpencilgraphiteelectrodeinhumanserumandartificialurine AT uzunberkay electrocatalyticdeterminationofuricacidwiththepolytartrazinemodifiedpencilgraphiteelectrodeinhumanserumandartificialurine |