Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty

Background: Revision hip arthroplasty presents a surgical challenge, necessitating meticulous preoperative planning to avert complications like periprosthetic fractures and aseptic loosening. Historically, assessment of the accuracy of three-dimensional (3D) versus two-dimensional (2D) templating ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Winter, Philipp, Fritsch, Ekkehard, Tschernig, Thomas, Goebel, Lars, Wolf, Milan, Müller, Manuel, Weise, Julius J., Orth, Patrick, Landgraeber, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536197/
https://www.ncbi.nlm.nih.gov/pubmed/37763727
http://dx.doi.org/10.3390/medicina59091608
_version_ 1785112808806940672
author Winter, Philipp
Fritsch, Ekkehard
Tschernig, Thomas
Goebel, Lars
Wolf, Milan
Müller, Manuel
Weise, Julius J.
Orth, Patrick
Landgraeber, Stefan
author_facet Winter, Philipp
Fritsch, Ekkehard
Tschernig, Thomas
Goebel, Lars
Wolf, Milan
Müller, Manuel
Weise, Julius J.
Orth, Patrick
Landgraeber, Stefan
author_sort Winter, Philipp
collection PubMed
description Background: Revision hip arthroplasty presents a surgical challenge, necessitating meticulous preoperative planning to avert complications like periprosthetic fractures and aseptic loosening. Historically, assessment of the accuracy of three-dimensional (3D) versus two-dimensional (2D) templating has focused exclusively on primary hip arthroplasty. Materials and Methods: In this retrospective study, we examined the accuracy of 3D templating for acetabular revision cups in 30 patients who underwent revision hip arthroplasty. Utilizing computed tomography scans of the patients’ pelvis and 3D templates of the implants (Aesculap Plasmafit, B. Braun; Aesculap Plasmafit Revision, B. Braun; Avantage Acetabular System, Zimmerbiomet, EcoFit 2M, Implantcast; Tritanium Revision, Stryker), we performed 3D templating and positioned the acetabular cup implants accordingly. To evaluate accuracy, we compared the planned sizes of the acetabular cups in 2D and 3D with the sizes implanted during surgery. Results: An analysis was performed to examine potential influences on templating accuracy, specifically considering factors such as gender and body mass index (BMI). Significant statistical differences (p < 0.001) in the accuracy of size prediction were observed between 3D and 2D templating. Personalized 3D templating exhibited an accuracy rate of 66.7% for the correct prediction of the size of the acetabular cup, while 2D templating achieved an exact size prediction in only 26.7% of cases. There were no statistically significant differences between the 2D and 3D templating methods regarding gender or BMI. Conclusion: This study demonstrates that 3D templating improves the accuracy of predicting acetabular cup sizes in revision arthroplasty when compared to 2D templating. However, it should be noted that the predicted implant size generated through 3D templating tended to overestimate the implanted implant size by an average of 1.3 sizes.
format Online
Article
Text
id pubmed-10536197
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105361972023-09-29 Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty Winter, Philipp Fritsch, Ekkehard Tschernig, Thomas Goebel, Lars Wolf, Milan Müller, Manuel Weise, Julius J. Orth, Patrick Landgraeber, Stefan Medicina (Kaunas) Article Background: Revision hip arthroplasty presents a surgical challenge, necessitating meticulous preoperative planning to avert complications like periprosthetic fractures and aseptic loosening. Historically, assessment of the accuracy of three-dimensional (3D) versus two-dimensional (2D) templating has focused exclusively on primary hip arthroplasty. Materials and Methods: In this retrospective study, we examined the accuracy of 3D templating for acetabular revision cups in 30 patients who underwent revision hip arthroplasty. Utilizing computed tomography scans of the patients’ pelvis and 3D templates of the implants (Aesculap Plasmafit, B. Braun; Aesculap Plasmafit Revision, B. Braun; Avantage Acetabular System, Zimmerbiomet, EcoFit 2M, Implantcast; Tritanium Revision, Stryker), we performed 3D templating and positioned the acetabular cup implants accordingly. To evaluate accuracy, we compared the planned sizes of the acetabular cups in 2D and 3D with the sizes implanted during surgery. Results: An analysis was performed to examine potential influences on templating accuracy, specifically considering factors such as gender and body mass index (BMI). Significant statistical differences (p < 0.001) in the accuracy of size prediction were observed between 3D and 2D templating. Personalized 3D templating exhibited an accuracy rate of 66.7% for the correct prediction of the size of the acetabular cup, while 2D templating achieved an exact size prediction in only 26.7% of cases. There were no statistically significant differences between the 2D and 3D templating methods regarding gender or BMI. Conclusion: This study demonstrates that 3D templating improves the accuracy of predicting acetabular cup sizes in revision arthroplasty when compared to 2D templating. However, it should be noted that the predicted implant size generated through 3D templating tended to overestimate the implanted implant size by an average of 1.3 sizes. MDPI 2023-09-06 /pmc/articles/PMC10536197/ /pubmed/37763727 http://dx.doi.org/10.3390/medicina59091608 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Winter, Philipp
Fritsch, Ekkehard
Tschernig, Thomas
Goebel, Lars
Wolf, Milan
Müller, Manuel
Weise, Julius J.
Orth, Patrick
Landgraeber, Stefan
Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty
title Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty
title_full Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty
title_fullStr Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty
title_full_unstemmed Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty
title_short Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty
title_sort accuracy of personalized computed tomographic 3d templating for acetabular cup placement in revision arthroplasty
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536197/
https://www.ncbi.nlm.nih.gov/pubmed/37763727
http://dx.doi.org/10.3390/medicina59091608
work_keys_str_mv AT winterphilipp accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty
AT fritschekkehard accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty
AT tschernigthomas accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty
AT goebellars accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty
AT wolfmilan accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty
AT mullermanuel accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty
AT weisejuliusj accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty
AT orthpatrick accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty
AT landgraeberstefan accuracyofpersonalizedcomputedtomographic3dtemplatingforacetabularcupplacementinrevisionarthroplasty