Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536462/ https://www.ncbi.nlm.nih.gov/pubmed/37764284 http://dx.doi.org/10.3390/molecules28186508 |
_version_ | 1785112871226572800 |
---|---|
author | de Oliveira, Marcelo Melo, Elaine S. de Pádua da Silva, Thaís Carvalho Cardozo, Carla Maiara Lopes Siqueira, Igor Valadares Hamaji, Mariana Pereira Braga, Vanessa Torres Martin, Luiz Fernando Taranta Fonseca, Alessandro do Nascimento, Valter Aragão |
author_facet | de Oliveira, Marcelo Melo, Elaine S. de Pádua da Silva, Thaís Carvalho Cardozo, Carla Maiara Lopes Siqueira, Igor Valadares Hamaji, Mariana Pereira Braga, Vanessa Torres Martin, Luiz Fernando Taranta Fonseca, Alessandro do Nascimento, Valter Aragão |
author_sort | de Oliveira, Marcelo |
collection | PubMed |
description | The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical emission spectrometry (ICP OES). The limit of detection (LOD) and limit of quantification (LOQ) values for the quantified elements ranged from 0.0002–0.0363 (mg/L) and 0.0007–0.1211 (mg/L), respectively. High values of concentrations of Al (2.382 µg/g), As (0.204 µg/g), Ba (0.056 µg/g), Cd (0.051 µg/g), Co (1.085 µg/g), Cr (0.020 µg/g), Cu (0.023 µg/g), Fe (0.453 µg/g), Mg (24.284 µg/g), Mn (0.014 µg/g), Mo (0.046 µg/g), Ni (0.071 µg/g), Pb (0.049 µg/g), Se (0.365 µg/g), V (0.083 µg/g), and Zn (0.552 µg/g) were quantified in samples of eye drops with and without preservatives. The concentrations of As (5 samples) and Cd (3 samples) were higher than those allowed by the Brazilian Pharmacopoeia for impurities (parenteral use). The value of Co content (µg/g) in a sample was higher than the value established by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH Q3D (R2)) in the parenteral route. The daily eye drop instillation exposure (µg/day) was below the values from the parenteral-permitted daily exposure (PDE) set by the ICH Q3D guideline (R2). The presence of heavy metals in eye drops is an alert to regulatory agencies in several countries so that control and inspections can be carried out. |
format | Online Article Text |
id | pubmed-10536462 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105364622023-09-29 Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease de Oliveira, Marcelo Melo, Elaine S. de Pádua da Silva, Thaís Carvalho Cardozo, Carla Maiara Lopes Siqueira, Igor Valadares Hamaji, Mariana Pereira Braga, Vanessa Torres Martin, Luiz Fernando Taranta Fonseca, Alessandro do Nascimento, Valter Aragão Molecules Article The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical emission spectrometry (ICP OES). The limit of detection (LOD) and limit of quantification (LOQ) values for the quantified elements ranged from 0.0002–0.0363 (mg/L) and 0.0007–0.1211 (mg/L), respectively. High values of concentrations of Al (2.382 µg/g), As (0.204 µg/g), Ba (0.056 µg/g), Cd (0.051 µg/g), Co (1.085 µg/g), Cr (0.020 µg/g), Cu (0.023 µg/g), Fe (0.453 µg/g), Mg (24.284 µg/g), Mn (0.014 µg/g), Mo (0.046 µg/g), Ni (0.071 µg/g), Pb (0.049 µg/g), Se (0.365 µg/g), V (0.083 µg/g), and Zn (0.552 µg/g) were quantified in samples of eye drops with and without preservatives. The concentrations of As (5 samples) and Cd (3 samples) were higher than those allowed by the Brazilian Pharmacopoeia for impurities (parenteral use). The value of Co content (µg/g) in a sample was higher than the value established by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH Q3D (R2)) in the parenteral route. The daily eye drop instillation exposure (µg/day) was below the values from the parenteral-permitted daily exposure (PDE) set by the ICH Q3D guideline (R2). The presence of heavy metals in eye drops is an alert to regulatory agencies in several countries so that control and inspections can be carried out. MDPI 2023-09-07 /pmc/articles/PMC10536462/ /pubmed/37764284 http://dx.doi.org/10.3390/molecules28186508 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article de Oliveira, Marcelo Melo, Elaine S. de Pádua da Silva, Thaís Carvalho Cardozo, Carla Maiara Lopes Siqueira, Igor Valadares Hamaji, Mariana Pereira Braga, Vanessa Torres Martin, Luiz Fernando Taranta Fonseca, Alessandro do Nascimento, Valter Aragão Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease |
title | Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease |
title_full | Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease |
title_fullStr | Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease |
title_full_unstemmed | Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease |
title_short | Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease |
title_sort | quantification of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536462/ https://www.ncbi.nlm.nih.gov/pubmed/37764284 http://dx.doi.org/10.3390/molecules28186508 |
work_keys_str_mv | AT deoliveiramarcelo quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT meloelainesdepadua quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT dasilvathaiscarvalho quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT cardozocarlamaiaralopes quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT siqueiraigorvaladares quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT hamajimarianapereira quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT bragavanessatorres quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT martinluizfernandotaranta quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT fonsecaalessandro quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease AT donascimentovalteraragao quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease |