Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease

The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical...

Descripción completa

Detalles Bibliográficos
Autores principales: de Oliveira, Marcelo, Melo, Elaine S. de Pádua, da Silva, Thaís Carvalho, Cardozo, Carla Maiara Lopes, Siqueira, Igor Valadares, Hamaji, Mariana Pereira, Braga, Vanessa Torres, Martin, Luiz Fernando Taranta, Fonseca, Alessandro, do Nascimento, Valter Aragão
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536462/
https://www.ncbi.nlm.nih.gov/pubmed/37764284
http://dx.doi.org/10.3390/molecules28186508
_version_ 1785112871226572800
author de Oliveira, Marcelo
Melo, Elaine S. de Pádua
da Silva, Thaís Carvalho
Cardozo, Carla Maiara Lopes
Siqueira, Igor Valadares
Hamaji, Mariana Pereira
Braga, Vanessa Torres
Martin, Luiz Fernando Taranta
Fonseca, Alessandro
do Nascimento, Valter Aragão
author_facet de Oliveira, Marcelo
Melo, Elaine S. de Pádua
da Silva, Thaís Carvalho
Cardozo, Carla Maiara Lopes
Siqueira, Igor Valadares
Hamaji, Mariana Pereira
Braga, Vanessa Torres
Martin, Luiz Fernando Taranta
Fonseca, Alessandro
do Nascimento, Valter Aragão
author_sort de Oliveira, Marcelo
collection PubMed
description The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical emission spectrometry (ICP OES). The limit of detection (LOD) and limit of quantification (LOQ) values for the quantified elements ranged from 0.0002–0.0363 (mg/L) and 0.0007–0.1211 (mg/L), respectively. High values of concentrations of Al (2.382 µg/g), As (0.204 µg/g), Ba (0.056 µg/g), Cd (0.051 µg/g), Co (1.085 µg/g), Cr (0.020 µg/g), Cu (0.023 µg/g), Fe (0.453 µg/g), Mg (24.284 µg/g), Mn (0.014 µg/g), Mo (0.046 µg/g), Ni (0.071 µg/g), Pb (0.049 µg/g), Se (0.365 µg/g), V (0.083 µg/g), and Zn (0.552 µg/g) were quantified in samples of eye drops with and without preservatives. The concentrations of As (5 samples) and Cd (3 samples) were higher than those allowed by the Brazilian Pharmacopoeia for impurities (parenteral use). The value of Co content (µg/g) in a sample was higher than the value established by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH Q3D (R2)) in the parenteral route. The daily eye drop instillation exposure (µg/day) was below the values from the parenteral-permitted daily exposure (PDE) set by the ICH Q3D guideline (R2). The presence of heavy metals in eye drops is an alert to regulatory agencies in several countries so that control and inspections can be carried out.
format Online
Article
Text
id pubmed-10536462
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105364622023-09-29 Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease de Oliveira, Marcelo Melo, Elaine S. de Pádua da Silva, Thaís Carvalho Cardozo, Carla Maiara Lopes Siqueira, Igor Valadares Hamaji, Mariana Pereira Braga, Vanessa Torres Martin, Luiz Fernando Taranta Fonseca, Alessandro do Nascimento, Valter Aragão Molecules Article The aim of the study was to evaluate the presence of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease. The concentrations of Al, As, Ba, Cd, Co, Cu, Cr, Pb, Fe, Mg, Mn, Mo, Ni, Se, V, and Zn were determined in 19 eye drop samples using inductively coupled plasma optical emission spectrometry (ICP OES). The limit of detection (LOD) and limit of quantification (LOQ) values for the quantified elements ranged from 0.0002–0.0363 (mg/L) and 0.0007–0.1211 (mg/L), respectively. High values of concentrations of Al (2.382 µg/g), As (0.204 µg/g), Ba (0.056 µg/g), Cd (0.051 µg/g), Co (1.085 µg/g), Cr (0.020 µg/g), Cu (0.023 µg/g), Fe (0.453 µg/g), Mg (24.284 µg/g), Mn (0.014 µg/g), Mo (0.046 µg/g), Ni (0.071 µg/g), Pb (0.049 µg/g), Se (0.365 µg/g), V (0.083 µg/g), and Zn (0.552 µg/g) were quantified in samples of eye drops with and without preservatives. The concentrations of As (5 samples) and Cd (3 samples) were higher than those allowed by the Brazilian Pharmacopoeia for impurities (parenteral use). The value of Co content (µg/g) in a sample was higher than the value established by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH Q3D (R2)) in the parenteral route. The daily eye drop instillation exposure (µg/day) was below the values from the parenteral-permitted daily exposure (PDE) set by the ICH Q3D guideline (R2). The presence of heavy metals in eye drops is an alert to regulatory agencies in several countries so that control and inspections can be carried out. MDPI 2023-09-07 /pmc/articles/PMC10536462/ /pubmed/37764284 http://dx.doi.org/10.3390/molecules28186508 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
de Oliveira, Marcelo
Melo, Elaine S. de Pádua
da Silva, Thaís Carvalho
Cardozo, Carla Maiara Lopes
Siqueira, Igor Valadares
Hamaji, Mariana Pereira
Braga, Vanessa Torres
Martin, Luiz Fernando Taranta
Fonseca, Alessandro
do Nascimento, Valter Aragão
Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
title Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
title_full Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
title_fullStr Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
title_full_unstemmed Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
title_short Quantification of Metal(loid)s in Lubricating Eye Drops Used in the Treatment of Dry Eye Disease
title_sort quantification of metal(loid)s in lubricating eye drops used in the treatment of dry eye disease
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536462/
https://www.ncbi.nlm.nih.gov/pubmed/37764284
http://dx.doi.org/10.3390/molecules28186508
work_keys_str_mv AT deoliveiramarcelo quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT meloelainesdepadua quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT dasilvathaiscarvalho quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT cardozocarlamaiaralopes quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT siqueiraigorvaladares quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT hamajimarianapereira quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT bragavanessatorres quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT martinluizfernandotaranta quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT fonsecaalessandro quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease
AT donascimentovalteraragao quantificationofmetalloidsinlubricatingeyedropsusedinthetreatmentofdryeyedisease