Cargando…
Advancing Fault Detection in HVAC Systems: Unifying Gramian Angular Field and 2D Deep Convolutional Neural Networks for Enhanced Performance
Efficiency and comfort in buildings rely on on well-functioning HVAC systems. However, system faults can compromise performance. Modern data-driven fault detection methods, considering diverse techniques, encounter challenges in understanding intricate interactions and adapting to dynamic conditions...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536479/ https://www.ncbi.nlm.nih.gov/pubmed/37765746 http://dx.doi.org/10.3390/s23187690 |
_version_ | 1785112875267784704 |
---|---|
author | Tun, Wunna Wong, Kwok-Wai (Johnny) Ling, Sai-Ho |
author_facet | Tun, Wunna Wong, Kwok-Wai (Johnny) Ling, Sai-Ho |
author_sort | Tun, Wunna |
collection | PubMed |
description | Efficiency and comfort in buildings rely on on well-functioning HVAC systems. However, system faults can compromise performance. Modern data-driven fault detection methods, considering diverse techniques, encounter challenges in understanding intricate interactions and adapting to dynamic conditions present in HVAC systems during occupancy periods. Implementing fault detection during active operation, which aligns with real-world scenarios and captures dynamic interactions and environmental changes, is considered highly valuable. To address this, utilizing the dynamic simulation system HVAC SIMulation PLUS (HVACSIM+), an HVAC fault model was developed using 194 sensor signals from each HVAC component within a single-story, four-room building. The advanced HVAC fault detection framework, leveraging simulated HVAC operational scenarios with the Gramian angular field (GAF) and two-dimensional convolutional neural networks (GAF-2DCNNs), offers a robust and proactive solution. By utilizing the GAF capacity to convert time-series sensor data into informative 2D images, integrated with 2DCNN for automated feature extraction, hidden temporal relationships within 1D signals are captured. After training on nine significant HVAC faults and normal conditions during occupancy, the effectiveness of the proposed GAF-2DCNN is evaluated through comparisons with support vector machine (SVM), random forest (RF), and hybrid RF-SVM, one-dimensional convolutional neural networks (1D-CNNs). The results demonstrates an impressive overall accuracy of 97%, accompanied by precision, recall, and F1 scores that surpass 90% for individual HVAC faults. Through the introduction of the unified approach that integrates HVACSIM+ simulated data and GAF-2DCNN, a notable enhancement in robustness and reliability for handling substantial HVAC faults is achieved. |
format | Online Article Text |
id | pubmed-10536479 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105364792023-09-29 Advancing Fault Detection in HVAC Systems: Unifying Gramian Angular Field and 2D Deep Convolutional Neural Networks for Enhanced Performance Tun, Wunna Wong, Kwok-Wai (Johnny) Ling, Sai-Ho Sensors (Basel) Article Efficiency and comfort in buildings rely on on well-functioning HVAC systems. However, system faults can compromise performance. Modern data-driven fault detection methods, considering diverse techniques, encounter challenges in understanding intricate interactions and adapting to dynamic conditions present in HVAC systems during occupancy periods. Implementing fault detection during active operation, which aligns with real-world scenarios and captures dynamic interactions and environmental changes, is considered highly valuable. To address this, utilizing the dynamic simulation system HVAC SIMulation PLUS (HVACSIM+), an HVAC fault model was developed using 194 sensor signals from each HVAC component within a single-story, four-room building. The advanced HVAC fault detection framework, leveraging simulated HVAC operational scenarios with the Gramian angular field (GAF) and two-dimensional convolutional neural networks (GAF-2DCNNs), offers a robust and proactive solution. By utilizing the GAF capacity to convert time-series sensor data into informative 2D images, integrated with 2DCNN for automated feature extraction, hidden temporal relationships within 1D signals are captured. After training on nine significant HVAC faults and normal conditions during occupancy, the effectiveness of the proposed GAF-2DCNN is evaluated through comparisons with support vector machine (SVM), random forest (RF), and hybrid RF-SVM, one-dimensional convolutional neural networks (1D-CNNs). The results demonstrates an impressive overall accuracy of 97%, accompanied by precision, recall, and F1 scores that surpass 90% for individual HVAC faults. Through the introduction of the unified approach that integrates HVACSIM+ simulated data and GAF-2DCNN, a notable enhancement in robustness and reliability for handling substantial HVAC faults is achieved. MDPI 2023-09-06 /pmc/articles/PMC10536479/ /pubmed/37765746 http://dx.doi.org/10.3390/s23187690 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Tun, Wunna Wong, Kwok-Wai (Johnny) Ling, Sai-Ho Advancing Fault Detection in HVAC Systems: Unifying Gramian Angular Field and 2D Deep Convolutional Neural Networks for Enhanced Performance |
title | Advancing Fault Detection in HVAC Systems: Unifying Gramian Angular Field and 2D Deep Convolutional Neural Networks for Enhanced Performance |
title_full | Advancing Fault Detection in HVAC Systems: Unifying Gramian Angular Field and 2D Deep Convolutional Neural Networks for Enhanced Performance |
title_fullStr | Advancing Fault Detection in HVAC Systems: Unifying Gramian Angular Field and 2D Deep Convolutional Neural Networks for Enhanced Performance |
title_full_unstemmed | Advancing Fault Detection in HVAC Systems: Unifying Gramian Angular Field and 2D Deep Convolutional Neural Networks for Enhanced Performance |
title_short | Advancing Fault Detection in HVAC Systems: Unifying Gramian Angular Field and 2D Deep Convolutional Neural Networks for Enhanced Performance |
title_sort | advancing fault detection in hvac systems: unifying gramian angular field and 2d deep convolutional neural networks for enhanced performance |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536479/ https://www.ncbi.nlm.nih.gov/pubmed/37765746 http://dx.doi.org/10.3390/s23187690 |
work_keys_str_mv | AT tunwunna advancingfaultdetectioninhvacsystemsunifyinggramianangularfieldand2ddeepconvolutionalneuralnetworksforenhancedperformance AT wongkwokwaijohnny advancingfaultdetectioninhvacsystemsunifyinggramianangularfieldand2ddeepconvolutionalneuralnetworksforenhancedperformance AT lingsaiho advancingfaultdetectioninhvacsystemsunifyinggramianangularfieldand2ddeepconvolutionalneuralnetworksforenhancedperformance |