Cargando…

A Stream Function Smoothing Method for the Design of MRI Gradient Coils on Non-Developable Surfaces

Insert gradient coils with similar imaging body shapes typically have smaller dimensions and higher spatial efficiency. This often allows the gradient coils the achievement of stronger and faster gradient fields. Thus, improving existing methods to make them applicable to the design of MRI gradient...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Bohan, Ren, Hao, Zuo, Tongxing, Liu, Zhenyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536939/
https://www.ncbi.nlm.nih.gov/pubmed/37765969
http://dx.doi.org/10.3390/s23187912
_version_ 1785112986468220928
author Yang, Bohan
Ren, Hao
Zuo, Tongxing
Liu, Zhenyu
author_facet Yang, Bohan
Ren, Hao
Zuo, Tongxing
Liu, Zhenyu
author_sort Yang, Bohan
collection PubMed
description Insert gradient coils with similar imaging body shapes typically have smaller dimensions and higher spatial efficiency. This often allows the gradient coils the achievement of stronger and faster gradient fields. Thus, improving existing methods to make them applicable to the design of MRI gradient coils on complex surfaces has also become a challenge. This article proposes an algorithm that smooths the implicitly expressed stream function based on the intrinsic surface Laplace–Beltrami operator. This algorithm can be used to simplify the design procedure of MRI gradient coils on non-developable surfaces. The following steps are performed by the proposed algorithm: an initial design of the stream function configuration, extraction of the surface mesh, discretization of the surface smoothing operator, and a smoothing of the contour lines. To evaluate the quality of the smoothed streamline configuration, several technical parameter metrics—including magnetic field accuracy, coil power consumption, theoretical minimum wire spacing, and the maximum curvature of the contour lines—were evaluated. The proposed method was successfully validated in a design gradient coil on both developable and non-developable surfaces. All examples evolved from an initial value with a locally non-smooth and complex topological configuration to a smooth result while maintaining high magnetic field accuracy.
format Online
Article
Text
id pubmed-10536939
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105369392023-09-29 A Stream Function Smoothing Method for the Design of MRI Gradient Coils on Non-Developable Surfaces Yang, Bohan Ren, Hao Zuo, Tongxing Liu, Zhenyu Sensors (Basel) Article Insert gradient coils with similar imaging body shapes typically have smaller dimensions and higher spatial efficiency. This often allows the gradient coils the achievement of stronger and faster gradient fields. Thus, improving existing methods to make them applicable to the design of MRI gradient coils on complex surfaces has also become a challenge. This article proposes an algorithm that smooths the implicitly expressed stream function based on the intrinsic surface Laplace–Beltrami operator. This algorithm can be used to simplify the design procedure of MRI gradient coils on non-developable surfaces. The following steps are performed by the proposed algorithm: an initial design of the stream function configuration, extraction of the surface mesh, discretization of the surface smoothing operator, and a smoothing of the contour lines. To evaluate the quality of the smoothed streamline configuration, several technical parameter metrics—including magnetic field accuracy, coil power consumption, theoretical minimum wire spacing, and the maximum curvature of the contour lines—were evaluated. The proposed method was successfully validated in a design gradient coil on both developable and non-developable surfaces. All examples evolved from an initial value with a locally non-smooth and complex topological configuration to a smooth result while maintaining high magnetic field accuracy. MDPI 2023-09-15 /pmc/articles/PMC10536939/ /pubmed/37765969 http://dx.doi.org/10.3390/s23187912 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yang, Bohan
Ren, Hao
Zuo, Tongxing
Liu, Zhenyu
A Stream Function Smoothing Method for the Design of MRI Gradient Coils on Non-Developable Surfaces
title A Stream Function Smoothing Method for the Design of MRI Gradient Coils on Non-Developable Surfaces
title_full A Stream Function Smoothing Method for the Design of MRI Gradient Coils on Non-Developable Surfaces
title_fullStr A Stream Function Smoothing Method for the Design of MRI Gradient Coils on Non-Developable Surfaces
title_full_unstemmed A Stream Function Smoothing Method for the Design of MRI Gradient Coils on Non-Developable Surfaces
title_short A Stream Function Smoothing Method for the Design of MRI Gradient Coils on Non-Developable Surfaces
title_sort stream function smoothing method for the design of mri gradient coils on non-developable surfaces
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10536939/
https://www.ncbi.nlm.nih.gov/pubmed/37765969
http://dx.doi.org/10.3390/s23187912
work_keys_str_mv AT yangbohan astreamfunctionsmoothingmethodforthedesignofmrigradientcoilsonnondevelopablesurfaces
AT renhao astreamfunctionsmoothingmethodforthedesignofmrigradientcoilsonnondevelopablesurfaces
AT zuotongxing astreamfunctionsmoothingmethodforthedesignofmrigradientcoilsonnondevelopablesurfaces
AT liuzhenyu astreamfunctionsmoothingmethodforthedesignofmrigradientcoilsonnondevelopablesurfaces
AT yangbohan streamfunctionsmoothingmethodforthedesignofmrigradientcoilsonnondevelopablesurfaces
AT renhao streamfunctionsmoothingmethodforthedesignofmrigradientcoilsonnondevelopablesurfaces
AT zuotongxing streamfunctionsmoothingmethodforthedesignofmrigradientcoilsonnondevelopablesurfaces
AT liuzhenyu streamfunctionsmoothingmethodforthedesignofmrigradientcoilsonnondevelopablesurfaces