Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines

The article deals with a diagnosis of multiple leaks from liquid transmission pipelines using analytical methods. Such solutions, based on advanced mathematical models of pipeline flow dynamics, usually turn out to be very complex and time-consuming. However, under certain operating conditions, a si...

Descripción completa

Detalles Bibliográficos
Autores principales: Ostapkowicz, Pawel, Bratek, Andrzej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10537460/
https://www.ncbi.nlm.nih.gov/pubmed/37765807
http://dx.doi.org/10.3390/s23187751
_version_ 1785113108225720320
author Ostapkowicz, Pawel
Bratek, Andrzej
author_facet Ostapkowicz, Pawel
Bratek, Andrzej
author_sort Ostapkowicz, Pawel
collection PubMed
description The article deals with a diagnosis of multiple leaks from liquid transmission pipelines using analytical methods. Such solutions, based on advanced mathematical models of pipeline flow dynamics, usually turn out to be very complex and time-consuming. However, under certain operating conditions, a simpler approach may also be useful. Such an idea is presented in this paper, proposing two simplified methods for diagnosing double leakages. In principle, these methods apply to both simultaneous and non-simultaneous leaks. The first one uses a static model of a pipeline involving two leaks and takes advantage of the minimization of the objective function defined as the squared deviation of the modeled pressures from the pressures measured on the pipeline. The second method uses a pipeline flow model of a static type in combination with a gradient indicator aimed at detecting leaks and employing algorithms assigned to determining the location and size of leaks. The results of methods’ validation, based on tests carried out with the use of measurement data obtained from an experimental water pipeline, were also presented. The outcomes of the performed tests proved the methods’ effectiveness in terms of detection, isolation, localization, and intensity estimation of both simultaneous and non-simultaneous double leakages.
format Online
Article
Text
id pubmed-10537460
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105374602023-09-29 Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines Ostapkowicz, Pawel Bratek, Andrzej Sensors (Basel) Article The article deals with a diagnosis of multiple leaks from liquid transmission pipelines using analytical methods. Such solutions, based on advanced mathematical models of pipeline flow dynamics, usually turn out to be very complex and time-consuming. However, under certain operating conditions, a simpler approach may also be useful. Such an idea is presented in this paper, proposing two simplified methods for diagnosing double leakages. In principle, these methods apply to both simultaneous and non-simultaneous leaks. The first one uses a static model of a pipeline involving two leaks and takes advantage of the minimization of the objective function defined as the squared deviation of the modeled pressures from the pressures measured on the pipeline. The second method uses a pipeline flow model of a static type in combination with a gradient indicator aimed at detecting leaks and employing algorithms assigned to determining the location and size of leaks. The results of methods’ validation, based on tests carried out with the use of measurement data obtained from an experimental water pipeline, were also presented. The outcomes of the performed tests proved the methods’ effectiveness in terms of detection, isolation, localization, and intensity estimation of both simultaneous and non-simultaneous double leakages. MDPI 2023-09-08 /pmc/articles/PMC10537460/ /pubmed/37765807 http://dx.doi.org/10.3390/s23187751 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ostapkowicz, Pawel
Bratek, Andrzej
Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines
title Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines
title_full Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines
title_fullStr Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines
title_full_unstemmed Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines
title_short Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines
title_sort two-leak case diagnosis based on static flow model for liquid transmission pipelines
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10537460/
https://www.ncbi.nlm.nih.gov/pubmed/37765807
http://dx.doi.org/10.3390/s23187751
work_keys_str_mv AT ostapkowiczpawel twoleakcasediagnosisbasedonstaticflowmodelforliquidtransmissionpipelines
AT bratekandrzej twoleakcasediagnosisbasedonstaticflowmodelforliquidtransmissionpipelines