Cargando…
Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines
The article deals with a diagnosis of multiple leaks from liquid transmission pipelines using analytical methods. Such solutions, based on advanced mathematical models of pipeline flow dynamics, usually turn out to be very complex and time-consuming. However, under certain operating conditions, a si...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10537460/ https://www.ncbi.nlm.nih.gov/pubmed/37765807 http://dx.doi.org/10.3390/s23187751 |
_version_ | 1785113108225720320 |
---|---|
author | Ostapkowicz, Pawel Bratek, Andrzej |
author_facet | Ostapkowicz, Pawel Bratek, Andrzej |
author_sort | Ostapkowicz, Pawel |
collection | PubMed |
description | The article deals with a diagnosis of multiple leaks from liquid transmission pipelines using analytical methods. Such solutions, based on advanced mathematical models of pipeline flow dynamics, usually turn out to be very complex and time-consuming. However, under certain operating conditions, a simpler approach may also be useful. Such an idea is presented in this paper, proposing two simplified methods for diagnosing double leakages. In principle, these methods apply to both simultaneous and non-simultaneous leaks. The first one uses a static model of a pipeline involving two leaks and takes advantage of the minimization of the objective function defined as the squared deviation of the modeled pressures from the pressures measured on the pipeline. The second method uses a pipeline flow model of a static type in combination with a gradient indicator aimed at detecting leaks and employing algorithms assigned to determining the location and size of leaks. The results of methods’ validation, based on tests carried out with the use of measurement data obtained from an experimental water pipeline, were also presented. The outcomes of the performed tests proved the methods’ effectiveness in terms of detection, isolation, localization, and intensity estimation of both simultaneous and non-simultaneous double leakages. |
format | Online Article Text |
id | pubmed-10537460 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105374602023-09-29 Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines Ostapkowicz, Pawel Bratek, Andrzej Sensors (Basel) Article The article deals with a diagnosis of multiple leaks from liquid transmission pipelines using analytical methods. Such solutions, based on advanced mathematical models of pipeline flow dynamics, usually turn out to be very complex and time-consuming. However, under certain operating conditions, a simpler approach may also be useful. Such an idea is presented in this paper, proposing two simplified methods for diagnosing double leakages. In principle, these methods apply to both simultaneous and non-simultaneous leaks. The first one uses a static model of a pipeline involving two leaks and takes advantage of the minimization of the objective function defined as the squared deviation of the modeled pressures from the pressures measured on the pipeline. The second method uses a pipeline flow model of a static type in combination with a gradient indicator aimed at detecting leaks and employing algorithms assigned to determining the location and size of leaks. The results of methods’ validation, based on tests carried out with the use of measurement data obtained from an experimental water pipeline, were also presented. The outcomes of the performed tests proved the methods’ effectiveness in terms of detection, isolation, localization, and intensity estimation of both simultaneous and non-simultaneous double leakages. MDPI 2023-09-08 /pmc/articles/PMC10537460/ /pubmed/37765807 http://dx.doi.org/10.3390/s23187751 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ostapkowicz, Pawel Bratek, Andrzej Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines |
title | Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines |
title_full | Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines |
title_fullStr | Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines |
title_full_unstemmed | Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines |
title_short | Two-Leak Case Diagnosis Based on Static Flow Model for Liquid Transmission Pipelines |
title_sort | two-leak case diagnosis based on static flow model for liquid transmission pipelines |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10537460/ https://www.ncbi.nlm.nih.gov/pubmed/37765807 http://dx.doi.org/10.3390/s23187751 |
work_keys_str_mv | AT ostapkowiczpawel twoleakcasediagnosisbasedonstaticflowmodelforliquidtransmissionpipelines AT bratekandrzej twoleakcasediagnosisbasedonstaticflowmodelforliquidtransmissionpipelines |