Cargando…
Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters
The use of the USP IV apparatus (flow-through cell) has gained acceptance in recent years due to its versatility and ability to discriminate due to its hydrodynamic conditions. Therefore, the objective of the present study was to develop a discriminative dissolution method in the USP IV apparatus us...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10537472/ https://www.ncbi.nlm.nih.gov/pubmed/37765161 http://dx.doi.org/10.3390/pharmaceutics15092191 |
_version_ | 1785113111028563968 |
---|---|
author | Solis-Cruz, Bruno Hernandez-Patlan, Daniel Morales Hipólito, Elvia A. Tellez-Isaias, Guillermo Alcántara Pineda, Alejandro López-Arellano, Raquel |
author_facet | Solis-Cruz, Bruno Hernandez-Patlan, Daniel Morales Hipólito, Elvia A. Tellez-Isaias, Guillermo Alcántara Pineda, Alejandro López-Arellano, Raquel |
author_sort | Solis-Cruz, Bruno |
collection | PubMed |
description | The use of the USP IV apparatus (flow-through cell) has gained acceptance in recent years due to its versatility and ability to discriminate due to its hydrodynamic conditions. Therefore, the objective of the present study was to develop a discriminative dissolution method in the USP IV apparatus using the open-loop configuration, as well as to propose a method to compare non-cumulative dissolution profiles obtained in the open-loop configuration considering kinetic parameters and validate its predictive power through its comparison with independent and dependent methods using five commercial immediate-release tablet drugs (one reference drug and four generic drugs) of metoprolol tartrate as a model drug. The comparison of the non-accumulated dissolution profiles consisted of determining the geometric ratio of C(max), AUC(0)(∞), AUC(0)(Cmax,) and T(max) (kinetic parameters) of the generic/reference drugs, whereby generic drugs “C” and “D” presented the highest probability of similarity since their 90% confidence intervals were included, or they were very close to the acceptance interval (80.00–125.00%). These results were consistent with the f(2), bootstrap f(2,) and dissolution efficiency approaches (independent models). In conclusion, the proposed comparison method can be an important tool to establish similarity in dissolution profiles and to facilitate the development/selection of new formulations and positively ensure bioequivalence in clinical studies. |
format | Online Article Text |
id | pubmed-10537472 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105374722023-09-29 Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters Solis-Cruz, Bruno Hernandez-Patlan, Daniel Morales Hipólito, Elvia A. Tellez-Isaias, Guillermo Alcántara Pineda, Alejandro López-Arellano, Raquel Pharmaceutics Article The use of the USP IV apparatus (flow-through cell) has gained acceptance in recent years due to its versatility and ability to discriminate due to its hydrodynamic conditions. Therefore, the objective of the present study was to develop a discriminative dissolution method in the USP IV apparatus using the open-loop configuration, as well as to propose a method to compare non-cumulative dissolution profiles obtained in the open-loop configuration considering kinetic parameters and validate its predictive power through its comparison with independent and dependent methods using five commercial immediate-release tablet drugs (one reference drug and four generic drugs) of metoprolol tartrate as a model drug. The comparison of the non-accumulated dissolution profiles consisted of determining the geometric ratio of C(max), AUC(0)(∞), AUC(0)(Cmax,) and T(max) (kinetic parameters) of the generic/reference drugs, whereby generic drugs “C” and “D” presented the highest probability of similarity since their 90% confidence intervals were included, or they were very close to the acceptance interval (80.00–125.00%). These results were consistent with the f(2), bootstrap f(2,) and dissolution efficiency approaches (independent models). In conclusion, the proposed comparison method can be an important tool to establish similarity in dissolution profiles and to facilitate the development/selection of new formulations and positively ensure bioequivalence in clinical studies. MDPI 2023-08-24 /pmc/articles/PMC10537472/ /pubmed/37765161 http://dx.doi.org/10.3390/pharmaceutics15092191 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Solis-Cruz, Bruno Hernandez-Patlan, Daniel Morales Hipólito, Elvia A. Tellez-Isaias, Guillermo Alcántara Pineda, Alejandro López-Arellano, Raquel Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters |
title | Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters |
title_full | Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters |
title_fullStr | Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters |
title_full_unstemmed | Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters |
title_short | Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters |
title_sort | discriminative dissolution method using the open-loop configuration of the usp iv apparatus to compare dissolution profiles of metoprolol tartrate immediate-release tablets: use of kinetic parameters |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10537472/ https://www.ncbi.nlm.nih.gov/pubmed/37765161 http://dx.doi.org/10.3390/pharmaceutics15092191 |
work_keys_str_mv | AT soliscruzbruno discriminativedissolutionmethodusingtheopenloopconfigurationoftheuspivapparatustocomparedissolutionprofilesofmetoprololtartrateimmediatereleasetabletsuseofkineticparameters AT hernandezpatlandaniel discriminativedissolutionmethodusingtheopenloopconfigurationoftheuspivapparatustocomparedissolutionprofilesofmetoprololtartrateimmediatereleasetabletsuseofkineticparameters AT moraleshipolitoelviaa discriminativedissolutionmethodusingtheopenloopconfigurationoftheuspivapparatustocomparedissolutionprofilesofmetoprololtartrateimmediatereleasetabletsuseofkineticparameters AT tellezisaiasguillermo discriminativedissolutionmethodusingtheopenloopconfigurationoftheuspivapparatustocomparedissolutionprofilesofmetoprololtartrateimmediatereleasetabletsuseofkineticparameters AT alcantarapinedaalejandro discriminativedissolutionmethodusingtheopenloopconfigurationoftheuspivapparatustocomparedissolutionprofilesofmetoprololtartrateimmediatereleasetabletsuseofkineticparameters AT lopezarellanoraquel discriminativedissolutionmethodusingtheopenloopconfigurationoftheuspivapparatustocomparedissolutionprofilesofmetoprololtartrateimmediatereleasetabletsuseofkineticparameters |