Cargando…
Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism
PURPOSE: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. METHODS: The present study included a mono...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10538836/ https://www.ncbi.nlm.nih.gov/pubmed/37530266 http://dx.doi.org/10.4103/IJO.IJO_3385_22 |
_version_ | 1785113388108480512 |
---|---|
author | Jin, Tianru Yu, Lan Li, Jingjing Zhou, Yanwen |
author_facet | Jin, Tianru Yu, Lan Li, Jingjing Zhou, Yanwen |
author_sort | Jin, Tianru |
collection | PubMed |
description | PURPOSE: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. METHODS: The present study included a mono-centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either “with-the-rule” (WTR) or “against-the-rule” (ATR) on the basis of the steep anterior corneal meridian. The post-operative refractive astigmatic prediction error was analyzed 1 month post-operatively using the vector analysis by the Alpins method and double-angle plots method. RESULTS: The correction indexes were 1.14 ± 0.29 in the ATR eyes and 1.25 ± 0.18 for the WTR eyes, indicating a tendency toward over-correction. The mean over-correction was 0.22 ± 0.52D in the ATR group and 0.65 ± 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 ± 0.42 D versus 0.64 ± 0.39 D; P = 0.54). The ATR group yielded better results, with 48% <0.50D prediction error in the main analysis. CONCLUSIONS: The results suggested that in cases of high PCA, the toric IOL calculation, which was performed using TCA, may cause a potential over-correction in the ATR and WTR eyes. For ATR eyes, over-correction led to slight disruption of post-operative visual quality because of the “with-the-rule” residual astigmatism after operation. Therefore, we suggested using TCA for toric IOL calculation in ATR eyes. |
format | Online Article Text |
id | pubmed-10538836 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-105388362023-09-29 Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism Jin, Tianru Yu, Lan Li, Jingjing Zhou, Yanwen Indian J Ophthalmol Original Article PURPOSE: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. METHODS: The present study included a mono-centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either “with-the-rule” (WTR) or “against-the-rule” (ATR) on the basis of the steep anterior corneal meridian. The post-operative refractive astigmatic prediction error was analyzed 1 month post-operatively using the vector analysis by the Alpins method and double-angle plots method. RESULTS: The correction indexes were 1.14 ± 0.29 in the ATR eyes and 1.25 ± 0.18 for the WTR eyes, indicating a tendency toward over-correction. The mean over-correction was 0.22 ± 0.52D in the ATR group and 0.65 ± 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 ± 0.42 D versus 0.64 ± 0.39 D; P = 0.54). The ATR group yielded better results, with 48% <0.50D prediction error in the main analysis. CONCLUSIONS: The results suggested that in cases of high PCA, the toric IOL calculation, which was performed using TCA, may cause a potential over-correction in the ATR and WTR eyes. For ATR eyes, over-correction led to slight disruption of post-operative visual quality because of the “with-the-rule” residual astigmatism after operation. Therefore, we suggested using TCA for toric IOL calculation in ATR eyes. Wolters Kluwer - Medknow 2023-08 2023-08-01 /pmc/articles/PMC10538836/ /pubmed/37530266 http://dx.doi.org/10.4103/IJO.IJO_3385_22 Text en Copyright: © 2023 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Jin, Tianru Yu, Lan Li, Jingjing Zhou, Yanwen Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism |
title | Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism |
title_full | Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism |
title_fullStr | Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism |
title_full_unstemmed | Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism |
title_short | Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism |
title_sort | refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10538836/ https://www.ncbi.nlm.nih.gov/pubmed/37530266 http://dx.doi.org/10.4103/IJO.IJO_3385_22 |
work_keys_str_mv | AT jintianru refractiveoutcomesoftoricintraocularlensimplantationincasesofhighposteriorcornealastigmatism AT yulan refractiveoutcomesoftoricintraocularlensimplantationincasesofhighposteriorcornealastigmatism AT lijingjing refractiveoutcomesoftoricintraocularlensimplantationincasesofhighposteriorcornealastigmatism AT zhouyanwen refractiveoutcomesoftoricintraocularlensimplantationincasesofhighposteriorcornealastigmatism |