Cargando…

Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism

PURPOSE: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. METHODS: The present study included a mono...

Descripción completa

Detalles Bibliográficos
Autores principales: Jin, Tianru, Yu, Lan, Li, Jingjing, Zhou, Yanwen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10538836/
https://www.ncbi.nlm.nih.gov/pubmed/37530266
http://dx.doi.org/10.4103/IJO.IJO_3385_22
_version_ 1785113388108480512
author Jin, Tianru
Yu, Lan
Li, Jingjing
Zhou, Yanwen
author_facet Jin, Tianru
Yu, Lan
Li, Jingjing
Zhou, Yanwen
author_sort Jin, Tianru
collection PubMed
description PURPOSE: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. METHODS: The present study included a mono-centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either “with-the-rule” (WTR) or “against-the-rule” (ATR) on the basis of the steep anterior corneal meridian. The post-operative refractive astigmatic prediction error was analyzed 1 month post-operatively using the vector analysis by the Alpins method and double-angle plots method. RESULTS: The correction indexes were 1.14 ± 0.29 in the ATR eyes and 1.25 ± 0.18 for the WTR eyes, indicating a tendency toward over-correction. The mean over-correction was 0.22 ± 0.52D in the ATR group and 0.65 ± 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 ± 0.42 D versus 0.64 ± 0.39 D; P = 0.54). The ATR group yielded better results, with 48% <0.50D prediction error in the main analysis. CONCLUSIONS: The results suggested that in cases of high PCA, the toric IOL calculation, which was performed using TCA, may cause a potential over-correction in the ATR and WTR eyes. For ATR eyes, over-correction led to slight disruption of post-operative visual quality because of the “with-the-rule” residual astigmatism after operation. Therefore, we suggested using TCA for toric IOL calculation in ATR eyes.
format Online
Article
Text
id pubmed-10538836
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-105388362023-09-29 Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism Jin, Tianru Yu, Lan Li, Jingjing Zhou, Yanwen Indian J Ophthalmol Original Article PURPOSE: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. METHODS: The present study included a mono-centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either “with-the-rule” (WTR) or “against-the-rule” (ATR) on the basis of the steep anterior corneal meridian. The post-operative refractive astigmatic prediction error was analyzed 1 month post-operatively using the vector analysis by the Alpins method and double-angle plots method. RESULTS: The correction indexes were 1.14 ± 0.29 in the ATR eyes and 1.25 ± 0.18 for the WTR eyes, indicating a tendency toward over-correction. The mean over-correction was 0.22 ± 0.52D in the ATR group and 0.65 ± 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 ± 0.42 D versus 0.64 ± 0.39 D; P = 0.54). The ATR group yielded better results, with 48% <0.50D prediction error in the main analysis. CONCLUSIONS: The results suggested that in cases of high PCA, the toric IOL calculation, which was performed using TCA, may cause a potential over-correction in the ATR and WTR eyes. For ATR eyes, over-correction led to slight disruption of post-operative visual quality because of the “with-the-rule” residual astigmatism after operation. Therefore, we suggested using TCA for toric IOL calculation in ATR eyes. Wolters Kluwer - Medknow 2023-08 2023-08-01 /pmc/articles/PMC10538836/ /pubmed/37530266 http://dx.doi.org/10.4103/IJO.IJO_3385_22 Text en Copyright: © 2023 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Jin, Tianru
Yu, Lan
Li, Jingjing
Zhou, Yanwen
Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism
title Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism
title_full Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism
title_fullStr Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism
title_full_unstemmed Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism
title_short Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism
title_sort refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10538836/
https://www.ncbi.nlm.nih.gov/pubmed/37530266
http://dx.doi.org/10.4103/IJO.IJO_3385_22
work_keys_str_mv AT jintianru refractiveoutcomesoftoricintraocularlensimplantationincasesofhighposteriorcornealastigmatism
AT yulan refractiveoutcomesoftoricintraocularlensimplantationincasesofhighposteriorcornealastigmatism
AT lijingjing refractiveoutcomesoftoricintraocularlensimplantationincasesofhighposteriorcornealastigmatism
AT zhouyanwen refractiveoutcomesoftoricintraocularlensimplantationincasesofhighposteriorcornealastigmatism