Cargando…
Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from Anastomotic Leakage: A Case Report
A 64-year-old male patient who presented with symptoms indicative of hemolytic anemia was referred to our hospital. After obtaining the patient’s history, it was found that hemolysis occurred 14 years after he underwent ascending aortic replacement for acute type A aortic dissection. Enhanced comput...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10539129/ https://www.ncbi.nlm.nih.gov/pubmed/37779657 http://dx.doi.org/10.3400/avd.cr.23-00008 |
_version_ | 1785113436146892800 |
---|---|
author | Izaki, Keishiro Kawai, Yujiro Kobayashi, Kanako Itoh, Takahito Ohtsubo, Satoshi |
author_facet | Izaki, Keishiro Kawai, Yujiro Kobayashi, Kanako Itoh, Takahito Ohtsubo, Satoshi |
author_sort | Izaki, Keishiro |
collection | PubMed |
description | A 64-year-old male patient who presented with symptoms indicative of hemolytic anemia was referred to our hospital. After obtaining the patient’s history, it was found that hemolysis occurred 14 years after he underwent ascending aortic replacement for acute type A aortic dissection. Enhanced computed tomography revealed an aortic pseudoaneurysm at the proximal anastomosis, which was thought to be the cause of hemolysis. Furthermore, aortic valve regurgitation and dilatation of the sinus of Valsalva were also found on a transthoracic echocardiogram. Therefore, the Bentall procedure was performed. During the surgery, aortic pseudoaneurysm formation and vascular graft stenosis were observed. The postoperative course was uneventful, and hemolysis diminished soon after the surgery. |
format | Online Article Text |
id | pubmed-10539129 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology |
record_format | MEDLINE/PubMed |
spelling | pubmed-105391292023-09-30 Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from Anastomotic Leakage: A Case Report Izaki, Keishiro Kawai, Yujiro Kobayashi, Kanako Itoh, Takahito Ohtsubo, Satoshi Ann Vasc Dis Case Report A 64-year-old male patient who presented with symptoms indicative of hemolytic anemia was referred to our hospital. After obtaining the patient’s history, it was found that hemolysis occurred 14 years after he underwent ascending aortic replacement for acute type A aortic dissection. Enhanced computed tomography revealed an aortic pseudoaneurysm at the proximal anastomosis, which was thought to be the cause of hemolysis. Furthermore, aortic valve regurgitation and dilatation of the sinus of Valsalva were also found on a transthoracic echocardiogram. Therefore, the Bentall procedure was performed. During the surgery, aortic pseudoaneurysm formation and vascular graft stenosis were observed. The postoperative course was uneventful, and hemolysis diminished soon after the surgery. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2023-09-25 /pmc/articles/PMC10539129/ /pubmed/37779657 http://dx.doi.org/10.3400/avd.cr.23-00008 Text en © 2023 The Editorial Committee of Annals of Vascular Diseases. https://creativecommons.org/licenses/by-nc-sa/4.0/This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original. |
spellingShingle | Case Report Izaki, Keishiro Kawai, Yujiro Kobayashi, Kanako Itoh, Takahito Ohtsubo, Satoshi Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from Anastomotic Leakage: A Case Report |
title | Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from Anastomotic Leakage: A Case Report |
title_full | Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from Anastomotic Leakage: A Case Report |
title_fullStr | Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from Anastomotic Leakage: A Case Report |
title_full_unstemmed | Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from Anastomotic Leakage: A Case Report |
title_short | Hemolytic Anemia Occurring 14 Years after Ascending Aortic Replacement for Acute Type A Aortic Dissection Due to Aortic Pseudoaneurysm Derived from Anastomotic Leakage: A Case Report |
title_sort | hemolytic anemia occurring 14 years after ascending aortic replacement for acute type a aortic dissection due to aortic pseudoaneurysm derived from anastomotic leakage: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10539129/ https://www.ncbi.nlm.nih.gov/pubmed/37779657 http://dx.doi.org/10.3400/avd.cr.23-00008 |
work_keys_str_mv | AT izakikeishiro hemolyticanemiaoccurring14yearsafterascendingaorticreplacementforacutetypeaaorticdissectionduetoaorticpseudoaneurysmderivedfromanastomoticleakageacasereport AT kawaiyujiro hemolyticanemiaoccurring14yearsafterascendingaorticreplacementforacutetypeaaorticdissectionduetoaorticpseudoaneurysmderivedfromanastomoticleakageacasereport AT kobayashikanako hemolyticanemiaoccurring14yearsafterascendingaorticreplacementforacutetypeaaorticdissectionduetoaorticpseudoaneurysmderivedfromanastomoticleakageacasereport AT itohtakahito hemolyticanemiaoccurring14yearsafterascendingaorticreplacementforacutetypeaaorticdissectionduetoaorticpseudoaneurysmderivedfromanastomoticleakageacasereport AT ohtsubosatoshi hemolyticanemiaoccurring14yearsafterascendingaorticreplacementforacutetypeaaorticdissectionduetoaorticpseudoaneurysmderivedfromanastomoticleakageacasereport |