Cargando…

Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy

Background: The dose distribution in different optimization algorithm plans of stereotactic radiotherapy (SBRT) for locally advanced pancreatic cancer (LAPC) were compared and analyzed using monte carlo dose calculate algorithm (MC). Methods: A retrospective study analyzed 26 LAPC patients treated w...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Yongchun, Yu, Xuyao, Wang, Yuwen, Dong, Yang, Yuan, Zhiyong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10539394/
https://www.ncbi.nlm.nih.gov/pubmed/37779867
http://dx.doi.org/10.7150/jca.87596
_version_ 1785113491547357184
author Song, Yongchun
Yu, Xuyao
Wang, Yuwen
Dong, Yang
Yuan, Zhiyong
author_facet Song, Yongchun
Yu, Xuyao
Wang, Yuwen
Dong, Yang
Yuan, Zhiyong
author_sort Song, Yongchun
collection PubMed
description Background: The dose distribution in different optimization algorithm plans of stereotactic radiotherapy (SBRT) for locally advanced pancreatic cancer (LAPC) were compared and analyzed using monte carlo dose calculate algorithm (MC). Methods: A retrospective study analyzed 26 LAPC patients treated with SBRT. The SBRT plans were designed by raytracing (RT) and fine size pencil beam (FSPB) algorithms in the CyberKnife (CK) precision system, all of which met the requirements of clinical target dose and organ at risk (OAR). Keeping the original optimization parameters unchanged, the RT and FSPB algorithm plans were recalculated by MC algorithm. The accuracy of different algorithm plnas were compared and analyzed by using planning parameters and dose distribution. Results: There was no significant differences in the coverage and conformal index (CI) of the planned target volume (PTV) between RT and FSPB algorithm plans, but dose distribution of organ at risk (OAR) and the maximum dose outside the PTV boundary of 2 cm (D2cm) were lower in FSPB plans compared to RT plans, and this difference was statistically significant with p-values < 0.05. Compared to the MC algorithm, both RT algorithm and FSPB algorithm overestimated dose of the PTV and OAR. The RT algorithm was more consistent with the MC algorithm than the FSPB algorithm. The relative error of PTV coverage within the RT algorithm was 8.02% ± 1.53%, and the relative error range of OAR dose parameters was 3.32% -12.73%. Conclusion: Although the FSPB algorithm could achieve rapid dose drop-off around the PTV and lower dose distribution in the OAR for pancreatic cancer SBRT plans, the algorithm error were higher than the RT algorithm. RT and FSPB algorithm overestimated the dose in the target and OAR. That was important to evaluate the clinical plans.
format Online
Article
Text
id pubmed-10539394
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-105393942023-09-30 Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy Song, Yongchun Yu, Xuyao Wang, Yuwen Dong, Yang Yuan, Zhiyong J Cancer Research Paper Background: The dose distribution in different optimization algorithm plans of stereotactic radiotherapy (SBRT) for locally advanced pancreatic cancer (LAPC) were compared and analyzed using monte carlo dose calculate algorithm (MC). Methods: A retrospective study analyzed 26 LAPC patients treated with SBRT. The SBRT plans were designed by raytracing (RT) and fine size pencil beam (FSPB) algorithms in the CyberKnife (CK) precision system, all of which met the requirements of clinical target dose and organ at risk (OAR). Keeping the original optimization parameters unchanged, the RT and FSPB algorithm plans were recalculated by MC algorithm. The accuracy of different algorithm plnas were compared and analyzed by using planning parameters and dose distribution. Results: There was no significant differences in the coverage and conformal index (CI) of the planned target volume (PTV) between RT and FSPB algorithm plans, but dose distribution of organ at risk (OAR) and the maximum dose outside the PTV boundary of 2 cm (D2cm) were lower in FSPB plans compared to RT plans, and this difference was statistically significant with p-values < 0.05. Compared to the MC algorithm, both RT algorithm and FSPB algorithm overestimated dose of the PTV and OAR. The RT algorithm was more consistent with the MC algorithm than the FSPB algorithm. The relative error of PTV coverage within the RT algorithm was 8.02% ± 1.53%, and the relative error range of OAR dose parameters was 3.32% -12.73%. Conclusion: Although the FSPB algorithm could achieve rapid dose drop-off around the PTV and lower dose distribution in the OAR for pancreatic cancer SBRT plans, the algorithm error were higher than the RT algorithm. RT and FSPB algorithm overestimated the dose in the target and OAR. That was important to evaluate the clinical plans. Ivyspring International Publisher 2023-09-04 /pmc/articles/PMC10539394/ /pubmed/37779867 http://dx.doi.org/10.7150/jca.87596 Text en © The author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/). See http://ivyspring.com/terms for full terms and conditions.
spellingShingle Research Paper
Song, Yongchun
Yu, Xuyao
Wang, Yuwen
Dong, Yang
Yuan, Zhiyong
Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy
title Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy
title_full Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy
title_fullStr Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy
title_full_unstemmed Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy
title_short Accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy
title_sort accuracy analysis of different dose calculation algorithms for locally advanced pancreatic cancer stereotactic body radiotherapy
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10539394/
https://www.ncbi.nlm.nih.gov/pubmed/37779867
http://dx.doi.org/10.7150/jca.87596
work_keys_str_mv AT songyongchun accuracyanalysisofdifferentdosecalculationalgorithmsforlocallyadvancedpancreaticcancerstereotacticbodyradiotherapy
AT yuxuyao accuracyanalysisofdifferentdosecalculationalgorithmsforlocallyadvancedpancreaticcancerstereotacticbodyradiotherapy
AT wangyuwen accuracyanalysisofdifferentdosecalculationalgorithmsforlocallyadvancedpancreaticcancerstereotacticbodyradiotherapy
AT dongyang accuracyanalysisofdifferentdosecalculationalgorithmsforlocallyadvancedpancreaticcancerstereotacticbodyradiotherapy
AT yuanzhiyong accuracyanalysisofdifferentdosecalculationalgorithmsforlocallyadvancedpancreaticcancerstereotacticbodyradiotherapy