Cargando…

LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment

BACKGROUND: Lateral, All-Round and All-Inside (LARAI) portal is a viewing or working portal for observing and repairing the lesions of the lateral meniscus. However, there are safety concerns about popliteal artery (PA) injuries during the procedure. This study aimed to assess the safe distance betw...

Descripción completa

Detalles Bibliográficos
Autores principales: Long, Yi, Zhang, Zhengzheng, Zhou, Min, Hou, Jingyi, Zhou, Yunfeng, Jiang, Liang, Xu, Xiaoding, Yang, Rui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10541373/
https://www.ncbi.nlm.nih.gov/pubmed/37775551
http://dx.doi.org/10.1186/s10195-023-00727-1
_version_ 1785113894344196096
author Long, Yi
Zhang, Zhengzheng
Zhou, Min
Hou, Jingyi
Zhou, Yunfeng
Jiang, Liang
Xu, Xiaoding
Yang, Rui
author_facet Long, Yi
Zhang, Zhengzheng
Zhou, Min
Hou, Jingyi
Zhou, Yunfeng
Jiang, Liang
Xu, Xiaoding
Yang, Rui
author_sort Long, Yi
collection PubMed
description BACKGROUND: Lateral, All-Round and All-Inside (LARAI) portal is a viewing or working portal for observing and repairing the lesions of the lateral meniscus. However, there are safety concerns about popliteal artery (PA) injuries during the procedure. This study aimed to assess the safe distance between the trajectory of the LARAI portal and PA. MATERIALS AND METHODS: Both three-dimensional computed tomography (3D-CT) and cadavers were used to simulate the LARAI portal trajectory. In the 3D-CT study, between January 2020 and September 2020, 45 participants who underwent computed tomography angiography were included in the study. The shortest distance from the PA to the simulated trajectory needle (PS) was measured using 3D-CT. Mean −3SD −2 was calculated to assess the safety of the LARAI portal trajectory. If this value was more than zero, the trajectory was considered “safe.” In the cadaveric study, lower limbs from seven fresh-frozen cadavers were used to establish the “safe” trajectories of the LARAI portal, and the PS was measured. RESULTS: In the 3D-CT study, the longest PS (P < 0.001) was found 20 mm lateral to the edge of the patellar tendon trajectory at 0 mm from the posterior cruciate ligament (PCL). Safe trajectories were also found 10 mm, 15 mm, and 20 mm lateral to the edge of the patellar tendon at 0 mm from the PCL, as well as the 20 mm lateral to the edge of the patellar tendon at 3 mm from the PCL. The cadaveric study showed that the average PS of all safe trajectories closely adjoined to PCL was greater than 14 mm. CONCLUSIONS: The LARAI portal trajectory in the “figure of four” is safe, and the optimal insertion point is 10–20 mm lateral to the edge of the patellar tendon and closely adjoined to the posterolateral margin of the PCL at knee joint line level. LEVEL OF EVIDENCE: Level IV.
format Online
Article
Text
id pubmed-10541373
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-105413732023-10-01 LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment Long, Yi Zhang, Zhengzheng Zhou, Min Hou, Jingyi Zhou, Yunfeng Jiang, Liang Xu, Xiaoding Yang, Rui J Orthop Traumatol Original Article BACKGROUND: Lateral, All-Round and All-Inside (LARAI) portal is a viewing or working portal for observing and repairing the lesions of the lateral meniscus. However, there are safety concerns about popliteal artery (PA) injuries during the procedure. This study aimed to assess the safe distance between the trajectory of the LARAI portal and PA. MATERIALS AND METHODS: Both three-dimensional computed tomography (3D-CT) and cadavers were used to simulate the LARAI portal trajectory. In the 3D-CT study, between January 2020 and September 2020, 45 participants who underwent computed tomography angiography were included in the study. The shortest distance from the PA to the simulated trajectory needle (PS) was measured using 3D-CT. Mean −3SD −2 was calculated to assess the safety of the LARAI portal trajectory. If this value was more than zero, the trajectory was considered “safe.” In the cadaveric study, lower limbs from seven fresh-frozen cadavers were used to establish the “safe” trajectories of the LARAI portal, and the PS was measured. RESULTS: In the 3D-CT study, the longest PS (P < 0.001) was found 20 mm lateral to the edge of the patellar tendon trajectory at 0 mm from the posterior cruciate ligament (PCL). Safe trajectories were also found 10 mm, 15 mm, and 20 mm lateral to the edge of the patellar tendon at 0 mm from the PCL, as well as the 20 mm lateral to the edge of the patellar tendon at 3 mm from the PCL. The cadaveric study showed that the average PS of all safe trajectories closely adjoined to PCL was greater than 14 mm. CONCLUSIONS: The LARAI portal trajectory in the “figure of four” is safe, and the optimal insertion point is 10–20 mm lateral to the edge of the patellar tendon and closely adjoined to the posterolateral margin of the PCL at knee joint line level. LEVEL OF EVIDENCE: Level IV. Springer International Publishing 2023-09-29 2023-12 /pmc/articles/PMC10541373/ /pubmed/37775551 http://dx.doi.org/10.1186/s10195-023-00727-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Long, Yi
Zhang, Zhengzheng
Zhou, Min
Hou, Jingyi
Zhou, Yunfeng
Jiang, Liang
Xu, Xiaoding
Yang, Rui
LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment
title LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment
title_full LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment
title_fullStr LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment
title_full_unstemmed LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment
title_short LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment
title_sort larai portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10541373/
https://www.ncbi.nlm.nih.gov/pubmed/37775551
http://dx.doi.org/10.1186/s10195-023-00727-1
work_keys_str_mv AT longyi laraiportalprovidesasafemethodforlateralmeniscusrepairthreedimensionalcomputedtomographyandcadavericassessment
AT zhangzhengzheng laraiportalprovidesasafemethodforlateralmeniscusrepairthreedimensionalcomputedtomographyandcadavericassessment
AT zhoumin laraiportalprovidesasafemethodforlateralmeniscusrepairthreedimensionalcomputedtomographyandcadavericassessment
AT houjingyi laraiportalprovidesasafemethodforlateralmeniscusrepairthreedimensionalcomputedtomographyandcadavericassessment
AT zhouyunfeng laraiportalprovidesasafemethodforlateralmeniscusrepairthreedimensionalcomputedtomographyandcadavericassessment
AT jiangliang laraiportalprovidesasafemethodforlateralmeniscusrepairthreedimensionalcomputedtomographyandcadavericassessment
AT xuxiaoding laraiportalprovidesasafemethodforlateralmeniscusrepairthreedimensionalcomputedtomographyandcadavericassessment
AT yangrui laraiportalprovidesasafemethodforlateralmeniscusrepairthreedimensionalcomputedtomographyandcadavericassessment