Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial

BACKGROUND: The purpose of this study was to compare the effectiveness and safety of the MedAn videolaryngoscope with the Nishikawa blade (MedAn) vs the UE videolaryngoscope (UE) for intubation with a left-sided double-lumen endobronchial tube (LDLT) in patients with normal airways. MATERIAL/METHODS...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Yong, Zhang, Wenwen, Wang, Shuai, Yin, Hailing, Xu, Yajie, Fang, Zhaojing, Bao, Hongguang, Zhang, Chen, Wang, Xiaoliang, Liu, Wentao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10541791/
https://www.ncbi.nlm.nih.gov/pubmed/37749883
http://dx.doi.org/10.12659/MSM.940916
_version_ 1785113974675603456
author Zhang, Yong
Zhang, Wenwen
Wang, Shuai
Yin, Hailing
Xu, Yajie
Fang, Zhaojing
Bao, Hongguang
Zhang, Chen
Wang, Xiaoliang
Liu, Wentao
author_facet Zhang, Yong
Zhang, Wenwen
Wang, Shuai
Yin, Hailing
Xu, Yajie
Fang, Zhaojing
Bao, Hongguang
Zhang, Chen
Wang, Xiaoliang
Liu, Wentao
author_sort Zhang, Yong
collection PubMed
description BACKGROUND: The purpose of this study was to compare the effectiveness and safety of the MedAn videolaryngoscope with the Nishikawa blade (MedAn) vs the UE videolaryngoscope (UE) for intubation with a left-sided double-lumen endobronchial tube (LDLT) in patients with normal airways. MATERIAL/METHODS: We randomly categorized 106 patients scheduled to undergo elective thoracic surgery with LDLT for one-lung ventilation into 2 groups: the UE group (Group UE) and the MedAn group (Group MedAn), using the MedAn or UE for LDLT intubation. The primary outcome was time to successful intubation. The Cormack-Lehane classification of laryngeal view was the key secondary outcome. Other secondary outcomes included first-attempt and overall intubation success rates, laryngoscopy time, LDLT placement time, operators’ subjective evaluation of videolaryngoscopes, hemodynamic changes during videolaryngoscopic intubation, and adverse outcomes. RESULTS: The time to successful intubation and LDLT placement time of Group MedAn were 42.0 (32.35, 47.0) s and 23.0 (18.0, 26.0) s, and it was shorter than in Group UE (median, 42 s vs 49 s, 23 s vs 30 s, P<0.001). Group MedAn had a better laryngeal view (P=0.03) and less subglottic/tracheal mucosal injury (P<0.001) than Group UE. Moreover, the operators’ subjective grading of ease of laryngoscopy, quality of view, and ease of LDLT placement were higher in Group MedAn than in Group UE (P<0.05). CONCLUSIONS: Compared with the UE, the MedAn could reduce the intubation time and provide a better laryngeal view and sufficient intubation space for safer LDLT intubation in patients with normal airways.
format Online
Article
Text
id pubmed-10541791
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-105417912023-10-02 Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial Zhang, Yong Zhang, Wenwen Wang, Shuai Yin, Hailing Xu, Yajie Fang, Zhaojing Bao, Hongguang Zhang, Chen Wang, Xiaoliang Liu, Wentao Med Sci Monit Clinical Research BACKGROUND: The purpose of this study was to compare the effectiveness and safety of the MedAn videolaryngoscope with the Nishikawa blade (MedAn) vs the UE videolaryngoscope (UE) for intubation with a left-sided double-lumen endobronchial tube (LDLT) in patients with normal airways. MATERIAL/METHODS: We randomly categorized 106 patients scheduled to undergo elective thoracic surgery with LDLT for one-lung ventilation into 2 groups: the UE group (Group UE) and the MedAn group (Group MedAn), using the MedAn or UE for LDLT intubation. The primary outcome was time to successful intubation. The Cormack-Lehane classification of laryngeal view was the key secondary outcome. Other secondary outcomes included first-attempt and overall intubation success rates, laryngoscopy time, LDLT placement time, operators’ subjective evaluation of videolaryngoscopes, hemodynamic changes during videolaryngoscopic intubation, and adverse outcomes. RESULTS: The time to successful intubation and LDLT placement time of Group MedAn were 42.0 (32.35, 47.0) s and 23.0 (18.0, 26.0) s, and it was shorter than in Group UE (median, 42 s vs 49 s, 23 s vs 30 s, P<0.001). Group MedAn had a better laryngeal view (P=0.03) and less subglottic/tracheal mucosal injury (P<0.001) than Group UE. Moreover, the operators’ subjective grading of ease of laryngoscopy, quality of view, and ease of LDLT placement were higher in Group MedAn than in Group UE (P<0.05). CONCLUSIONS: Compared with the UE, the MedAn could reduce the intubation time and provide a better laryngeal view and sufficient intubation space for safer LDLT intubation in patients with normal airways. International Scientific Literature, Inc. 2023-09-26 /pmc/articles/PMC10541791/ /pubmed/37749883 http://dx.doi.org/10.12659/MSM.940916 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Zhang, Yong
Zhang, Wenwen
Wang, Shuai
Yin, Hailing
Xu, Yajie
Fang, Zhaojing
Bao, Hongguang
Zhang, Chen
Wang, Xiaoliang
Liu, Wentao
Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial
title Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial
title_full Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial
title_fullStr Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial
title_full_unstemmed Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial
title_short Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial
title_sort comparing the effectiveness and safety of medan with the nishikawa blade and ue videolaryngoscopes for left-sided double-lumen endobronchial tube intubation: a randomized controlled trial
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10541791/
https://www.ncbi.nlm.nih.gov/pubmed/37749883
http://dx.doi.org/10.12659/MSM.940916
work_keys_str_mv AT zhangyong comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT zhangwenwen comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT wangshuai comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT yinhailing comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT xuyajie comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT fangzhaojing comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT baohongguang comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT zhangchen comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT wangxiaoliang comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial
AT liuwentao comparingtheeffectivenessandsafetyofmedanwiththenishikawabladeanduevideolaryngoscopesforleftsideddoublelumenendobronchialtubeintubationarandomizedcontrolledtrial