Cargando…

Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial

BACKGROUND: The aim of the present study was to examine tunnel widening and clinical outcomes after anterior cruciate ligament reconstruction (ACLR) using two different fixation methods: aperture fixation with biodegradable interference screws versus all-inside ACLR with suspensory cortical buttons....

Descripción completa

Detalles Bibliográficos
Autores principales: Eichinger, Martin, Ploner, Martin, Degenhart, Gerald, Rudisch, Ansgar, Smekal, Vinzenz, Attal, René, Mayr, Raul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10541822/
https://www.ncbi.nlm.nih.gov/pubmed/37542556
http://dx.doi.org/10.1007/s00402-023-05001-x
_version_ 1785113981272195072
author Eichinger, Martin
Ploner, Martin
Degenhart, Gerald
Rudisch, Ansgar
Smekal, Vinzenz
Attal, René
Mayr, Raul
author_facet Eichinger, Martin
Ploner, Martin
Degenhart, Gerald
Rudisch, Ansgar
Smekal, Vinzenz
Attal, René
Mayr, Raul
author_sort Eichinger, Martin
collection PubMed
description BACKGROUND: The aim of the present study was to examine tunnel widening and clinical outcomes after anterior cruciate ligament reconstruction (ACLR) using two different fixation methods: aperture fixation with biodegradable interference screws versus all-inside ACLR with suspensory cortical buttons. METHODS: Tunnel widening was assessed using volumetric and diameter measurements on magnetic resonance imaging (MRI) scans directly after surgery, as well as 6 months and 2 and 5 years postoperatively. Clinical outcomes were assessed after 5 years with instrumented tibial anteroposterior translation measurement (KT-1000), single-leg hop testing, and the IKDC, Lysholm, and Tegner activity scores. RESULTS: At the final follow-up, the study population consisted of 21 patients, 12 of whom underwent screw fixation and 9 of whom had button fixation. 3 patients with all-inside ACLR had sustained early repeat ruptures within 6 months after surgery and had to be excluded from the further analysis. With screw fixation, the tibial tunnel volume changed significantly more over time compared to all-inside button fixation, with a larger initial increase at 6 months (from postoperative 2.9 ± 0.2 to 3.3 ± 0.2 cm(3) at 6 months versus 1.7 ± 0.1 to 1.9 ± 0.2 cm(3)) and a greater final decrease over 2–5 years postoperatively (from 3.1 ± 0.2 to 1.9 ± 0.2 cm(3) versus 1.8 ± 0.2 ± 0.1 to 1.3 ± 0.1 cm(3)) (P < 0.001). The femoral tunnel volume remained comparable between the two groups throughout the follow-up period, with an initial 1.6 ± 0.1 cm(3) in both groups and 1.2 ± 0.1 vs. 1.3 ± 0.1 after 5 years in the screw and button groups, respectively (P ≥ 0.314). The maximum tibial and femoral tunnel diameters were significantly larger with screw fixation at all four time points. Tibial diameters measured 11.1 ± 0.2, 12.3 ± 0.3, 12.3 ± 0.4, and 11.2 ± 0.4 mm in the screw group versus 8.1 ± 0.3, 8.9 ± 0.3, 9.1 ± 0.4 and 8.2 ± 0.5 mm in the button group (P < 0.001). Femoral diameters measured 8.6 ± 0.2, 10.5 ± 0.4, 10.2 ± 0.3, and 8.9 ± 0.3 versus 7.3 ± 0.3, 8.4 ± 0.4, 8.4 ± 0.3, 7.5 ± 0.3, respectively (P ≤ 0.007). Four patients (33%) in the screw group exceeded a diameter of 12 mm on the tibial side after 5 years versus none in the button group (not significant, P = 0.104). Tibial anteroposterior translation measurement with KT-1000 after 5 years was 2.3 ± 2.4 mm in the screw group versus 3.2 ± 3.5 mm in the button group (not significant, P = 0.602). There were no significant differences between the groups in any of the other clinical outcomes. CONCLUSION: Tibial tunnels in ACLR with screw fixation were associated with a larger increase in tunnel volume within the first 2 years and a greater decrease up to 5 years after surgery, while femoral tunnel volumes did not differ significantly. On the tibial side, the need for staged revision ACLR may be greater after biodegradable interference screw fixation if repeat ruptures occur, especially within the first 2 years after primary ACLR. Concerns may remain regarding a higher graft failure rate with all-inside ACLR. LEVEL OF EVIDENCE: II. RCT CONSORT: NCT01755819.
format Online
Article
Text
id pubmed-10541822
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-105418222023-10-02 Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial Eichinger, Martin Ploner, Martin Degenhart, Gerald Rudisch, Ansgar Smekal, Vinzenz Attal, René Mayr, Raul Arch Orthop Trauma Surg Arthroscopy and Sports Medicine BACKGROUND: The aim of the present study was to examine tunnel widening and clinical outcomes after anterior cruciate ligament reconstruction (ACLR) using two different fixation methods: aperture fixation with biodegradable interference screws versus all-inside ACLR with suspensory cortical buttons. METHODS: Tunnel widening was assessed using volumetric and diameter measurements on magnetic resonance imaging (MRI) scans directly after surgery, as well as 6 months and 2 and 5 years postoperatively. Clinical outcomes were assessed after 5 years with instrumented tibial anteroposterior translation measurement (KT-1000), single-leg hop testing, and the IKDC, Lysholm, and Tegner activity scores. RESULTS: At the final follow-up, the study population consisted of 21 patients, 12 of whom underwent screw fixation and 9 of whom had button fixation. 3 patients with all-inside ACLR had sustained early repeat ruptures within 6 months after surgery and had to be excluded from the further analysis. With screw fixation, the tibial tunnel volume changed significantly more over time compared to all-inside button fixation, with a larger initial increase at 6 months (from postoperative 2.9 ± 0.2 to 3.3 ± 0.2 cm(3) at 6 months versus 1.7 ± 0.1 to 1.9 ± 0.2 cm(3)) and a greater final decrease over 2–5 years postoperatively (from 3.1 ± 0.2 to 1.9 ± 0.2 cm(3) versus 1.8 ± 0.2 ± 0.1 to 1.3 ± 0.1 cm(3)) (P < 0.001). The femoral tunnel volume remained comparable between the two groups throughout the follow-up period, with an initial 1.6 ± 0.1 cm(3) in both groups and 1.2 ± 0.1 vs. 1.3 ± 0.1 after 5 years in the screw and button groups, respectively (P ≥ 0.314). The maximum tibial and femoral tunnel diameters were significantly larger with screw fixation at all four time points. Tibial diameters measured 11.1 ± 0.2, 12.3 ± 0.3, 12.3 ± 0.4, and 11.2 ± 0.4 mm in the screw group versus 8.1 ± 0.3, 8.9 ± 0.3, 9.1 ± 0.4 and 8.2 ± 0.5 mm in the button group (P < 0.001). Femoral diameters measured 8.6 ± 0.2, 10.5 ± 0.4, 10.2 ± 0.3, and 8.9 ± 0.3 versus 7.3 ± 0.3, 8.4 ± 0.4, 8.4 ± 0.3, 7.5 ± 0.3, respectively (P ≤ 0.007). Four patients (33%) in the screw group exceeded a diameter of 12 mm on the tibial side after 5 years versus none in the button group (not significant, P = 0.104). Tibial anteroposterior translation measurement with KT-1000 after 5 years was 2.3 ± 2.4 mm in the screw group versus 3.2 ± 3.5 mm in the button group (not significant, P = 0.602). There were no significant differences between the groups in any of the other clinical outcomes. CONCLUSION: Tibial tunnels in ACLR with screw fixation were associated with a larger increase in tunnel volume within the first 2 years and a greater decrease up to 5 years after surgery, while femoral tunnel volumes did not differ significantly. On the tibial side, the need for staged revision ACLR may be greater after biodegradable interference screw fixation if repeat ruptures occur, especially within the first 2 years after primary ACLR. Concerns may remain regarding a higher graft failure rate with all-inside ACLR. LEVEL OF EVIDENCE: II. RCT CONSORT: NCT01755819. Springer Berlin Heidelberg 2023-08-05 2023 /pmc/articles/PMC10541822/ /pubmed/37542556 http://dx.doi.org/10.1007/s00402-023-05001-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Arthroscopy and Sports Medicine
Eichinger, Martin
Ploner, Martin
Degenhart, Gerald
Rudisch, Ansgar
Smekal, Vinzenz
Attal, René
Mayr, Raul
Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial
title Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial
title_full Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial
title_fullStr Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial
title_full_unstemmed Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial
title_short Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial
title_sort tunnel widening after acl reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial
topic Arthroscopy and Sports Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10541822/
https://www.ncbi.nlm.nih.gov/pubmed/37542556
http://dx.doi.org/10.1007/s00402-023-05001-x
work_keys_str_mv AT eichingermartin tunnelwideningafteraclreconstructionwithdifferentfixationtechniquesaperturefixationwithbiodegradableinterferencescrewsversusallinsidetechniquewithsuspensorycorticalbuttons5yeardatafromaprospectiverandomizedtrial
AT plonermartin tunnelwideningafteraclreconstructionwithdifferentfixationtechniquesaperturefixationwithbiodegradableinterferencescrewsversusallinsidetechniquewithsuspensorycorticalbuttons5yeardatafromaprospectiverandomizedtrial
AT degenhartgerald tunnelwideningafteraclreconstructionwithdifferentfixationtechniquesaperturefixationwithbiodegradableinterferencescrewsversusallinsidetechniquewithsuspensorycorticalbuttons5yeardatafromaprospectiverandomizedtrial
AT rudischansgar tunnelwideningafteraclreconstructionwithdifferentfixationtechniquesaperturefixationwithbiodegradableinterferencescrewsversusallinsidetechniquewithsuspensorycorticalbuttons5yeardatafromaprospectiverandomizedtrial
AT smekalvinzenz tunnelwideningafteraclreconstructionwithdifferentfixationtechniquesaperturefixationwithbiodegradableinterferencescrewsversusallinsidetechniquewithsuspensorycorticalbuttons5yeardatafromaprospectiverandomizedtrial
AT attalrene tunnelwideningafteraclreconstructionwithdifferentfixationtechniquesaperturefixationwithbiodegradableinterferencescrewsversusallinsidetechniquewithsuspensorycorticalbuttons5yeardatafromaprospectiverandomizedtrial
AT mayrraul tunnelwideningafteraclreconstructionwithdifferentfixationtechniquesaperturefixationwithbiodegradableinterferencescrewsversusallinsidetechniquewithsuspensorycorticalbuttons5yeardatafromaprospectiverandomizedtrial