Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out
OBJECTIVE: This study aimed to introduce a method to extract the 3-dimensional spatial position of the femoral head implant from 2-dimensional fluoroscopic projections, allowing surgeons to assess fixation much more accurately and prevent cut-out complications in proximal femoral nailing. METHODS: T...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Turkish Association of Orthopaedics and Traumatology, and Turkish Society of Orthopaedics and Traumatology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10542487/ https://www.ncbi.nlm.nih.gov/pubmed/37670446 http://dx.doi.org/10.5152/j.aott.2023.22175 |
_version_ | 1785114104940199936 |
---|---|
author | Subaşı, Ömer Aslan, Lercan Oral, Atacan Demirhan, Mehmet Seyahi, Aksel Lazoğlu, İsmail |
author_facet | Subaşı, Ömer Aslan, Lercan Oral, Atacan Demirhan, Mehmet Seyahi, Aksel Lazoğlu, İsmail |
author_sort | Subaşı, Ömer |
collection | PubMed |
description | OBJECTIVE: This study aimed to introduce a method to extract the 3-dimensional spatial position of the femoral head implant from 2-dimensional fluoroscopic projections, allowing surgeons to assess fixation much more accurately and prevent cut-out complications in proximal femoral nailing. METHODS: To define a safety region for the tip in the femoral head, a novel 3-dimensional distance-based risk parameter called TSD3D was introduced. An intersection algorithm was developed that solely takes the fluoroscopic anteroposterior and lateral distances to reveal the 3-dimensional location of the screw or Kirschner wire tip, enabling the utilization of the 3-dimensional parameter. Orthogonal perspectives of 6 femur proximal bone substitutes with randomly inserted Kirschner wires were imaged under fluoroscopy. The developed algorithm was used to calculate the implant tip location in 3-dimensional from 2-dimensional images for each case. Algorithm accuracy was validated with the computed tomography-obtained 3-dimensional models of the same femur substitutes. RESULTS: The newly introduced risk parameter successfully visualizes 3-dimensional safety regions. Utilizing the 2-dimensional fluoroscopic distances as inputs to the algorithm, the 3-dimensional position of the implanted Kirschner wire tip is calculated with a maximum of 9.8% error for a single Cartesian-coordinate measurement comparison. CONCLUSION: By incorporating the newly introduced 3-dimensional risk parameter, surgeons can more precisely evaluate the position of the implant and avoid cut-out complications, instead of relying solely on misleading 2-dimensional fluoroscopic projections of the femoral head. |
format | Online Article Text |
id | pubmed-10542487 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Turkish Association of Orthopaedics and Traumatology, and Turkish Society of Orthopaedics and Traumatology |
record_format | MEDLINE/PubMed |
spelling | pubmed-105424872023-10-03 Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out Subaşı, Ömer Aslan, Lercan Oral, Atacan Demirhan, Mehmet Seyahi, Aksel Lazoğlu, İsmail Acta Orthop Traumatol Turc Research Article OBJECTIVE: This study aimed to introduce a method to extract the 3-dimensional spatial position of the femoral head implant from 2-dimensional fluoroscopic projections, allowing surgeons to assess fixation much more accurately and prevent cut-out complications in proximal femoral nailing. METHODS: To define a safety region for the tip in the femoral head, a novel 3-dimensional distance-based risk parameter called TSD3D was introduced. An intersection algorithm was developed that solely takes the fluoroscopic anteroposterior and lateral distances to reveal the 3-dimensional location of the screw or Kirschner wire tip, enabling the utilization of the 3-dimensional parameter. Orthogonal perspectives of 6 femur proximal bone substitutes with randomly inserted Kirschner wires were imaged under fluoroscopy. The developed algorithm was used to calculate the implant tip location in 3-dimensional from 2-dimensional images for each case. Algorithm accuracy was validated with the computed tomography-obtained 3-dimensional models of the same femur substitutes. RESULTS: The newly introduced risk parameter successfully visualizes 3-dimensional safety regions. Utilizing the 2-dimensional fluoroscopic distances as inputs to the algorithm, the 3-dimensional position of the implanted Kirschner wire tip is calculated with a maximum of 9.8% error for a single Cartesian-coordinate measurement comparison. CONCLUSION: By incorporating the newly introduced 3-dimensional risk parameter, surgeons can more precisely evaluate the position of the implant and avoid cut-out complications, instead of relying solely on misleading 2-dimensional fluoroscopic projections of the femoral head. Turkish Association of Orthopaedics and Traumatology, and Turkish Society of Orthopaedics and Traumatology 2023-07-01 /pmc/articles/PMC10542487/ /pubmed/37670446 http://dx.doi.org/10.5152/j.aott.2023.22175 Text en 2023 authors https://creativecommons.org/licenses/by-nc/4.0/ Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. (https://creativecommons.org/licenses/by-nc/4.0/) |
spellingShingle | Research Article Subaşı, Ömer Aslan, Lercan Oral, Atacan Demirhan, Mehmet Seyahi, Aksel Lazoğlu, İsmail Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out |
title | Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out |
title_full | Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out |
title_fullStr | Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out |
title_full_unstemmed | Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out |
title_short | Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out |
title_sort | intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10542487/ https://www.ncbi.nlm.nih.gov/pubmed/37670446 http://dx.doi.org/10.5152/j.aott.2023.22175 |
work_keys_str_mv | AT subasıomer intraoperativefluoroscopicsafetyassessmentoffemoralheadimplantswith3dimensionalriskparameterstominimizecutout AT aslanlercan intraoperativefluoroscopicsafetyassessmentoffemoralheadimplantswith3dimensionalriskparameterstominimizecutout AT oralatacan intraoperativefluoroscopicsafetyassessmentoffemoralheadimplantswith3dimensionalriskparameterstominimizecutout AT demirhanmehmet intraoperativefluoroscopicsafetyassessmentoffemoralheadimplantswith3dimensionalriskparameterstominimizecutout AT seyahiaksel intraoperativefluoroscopicsafetyassessmentoffemoralheadimplantswith3dimensionalriskparameterstominimizecutout AT lazogluismail intraoperativefluoroscopicsafetyassessmentoffemoralheadimplantswith3dimensionalriskparameterstominimizecutout |